Impedance-based Long-term Structural Health Monitoring for Tidal Current Power Plant Structure in Noisy Environments  

Min, Ji-Young (Civil and Environmental Engineering, KAlST)
Shim, Hyo-Jin (Civil and Environmental Engineering, KAlST)
Yun, Chung-Bang (Civil and Environmental Engineering, KAlST)
Yi, Jin-Hak (Coastal Engineering and Ocean Energy Research Department, KORDI)
Publication Information
Journal of Ocean Engineering and Technology / v.25, no.4, 2011 , pp. 59-65 More about this Journal
Abstract
In structural health monitoring (SHM) using electro-mechanical impedance signatures, it is a critical issue for extremely large structures to extract the best damage diagnosis results, while minimizing unknown environmental effects, including temperature, humidity, and acoustic vibration. If the impedance signatures fluctuate because of these factors, these fluctuations should be eliminated because they might hide the characteristics of the host structural damages. This paper presents a long-term SHM technique under an unknown noisy environment for tidal current power plant structures. The obtained impedance signatures contained significant variations during the measurements, especially in the audio frequency range. To eliminate these variations, a continuous principal component analysis was applied, and the results were compared with the conventional approach using the RMSD (Root Mean Square Deviation) and CC (Cross-correlation Coefficient) damage indices. Finally, it was found that this approach could be effectively used for long-term SHM in noisy environments.
Keywords
Piezoelectric sensors; Electro-mechanical impedance; Long-term structural health monitoring; Noisy environment; Principal component analysis;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 이소영, 김정태, 김헌태, 박우선 (2009). "가속도 계측을 통한 항만시설용 케이슨 구조체의 동적응답 분석", 한국해양공학회지, 제23권 제1호 pp 114-121.
2 Park, G., Kabeya, K., Cudney, H. H. and Inman, D. (1999). "Impedance-based Structual Health Monitoring for Temperature Varying Applications", JSME International Journal Series A, Vol. 42, pp 249-258.
3 Min, J., Park, S., Yun, C.B. and Song, B. (2010). "Development of a Low-cost Multifunctional Wireless Impedance Sensor Node", Smart Structures and Systems, Vol. 6, No. 5-6, pp. 689-709.   DOI   ScienceOn
4 Giurgiutiu, V., Reynolds, A. and Rogers, C.A. (1999). "Experi-mental Investigation of E/M Impedance Health Monitoring of Spot-welded Structure Joints", Journal of Intelligent Material Systems and Structures, Vol. 10, pp. 802-812.   DOI
5 Koo, K. Y., Park, S., Lee, J. -J., and Yun, C. -B. (2009). "Automated Impedance-based Structural Health Monitoring Incorporating Effective Frequency Shift for Compensating Temperature Effects", Journal of Intelligent Material Systems and Structures, Vol. 20, pp 367-377.   DOI
6 Liang, C., Sun, F.P. and Rogers, C.A. (1996). "Electro-mechanical Modeling of Active Material Systems", Smart Materials and Structures, Vol. 5, pp 171-186.   DOI   ScienceOn
7 Krzanowski, W.J. (2000). Principals of Multivatiate Analysis-A User's Perspective, Revised Edition, Oxford University, Press, Oxford.
8 Peairs, D.M., Tarazaga, P.A. and Inman, D.J. (2006). "A study of the Correlation between PZT and MFC Resonance Peaks and Damage Detection Frequency Intervals Using the Impedance Method", International Conference on Noise and Vibration Engineering, Leuven, Belgium.
9 Giurgiutiu, V. (2008). Structural Health Monitoring with Piezoelectric Wafer Active Sensors, Academic Press, USA, pp. 363-434.
10 Park, S., Shin, H-H. and Yun, C.B. (2009). "Wireless impedance sensor nodes for functions of structural damage identification and sensor self-diagnosis", Smart Materials and Structures, Vol. 18, pp 1-11.
11 Park, G., Sohn, H., Farrar, C.R. and Inman, D.J. (2003). "Overview of Piezoelectric Impedance-based Health Monitoring and Path Forward", Shock Vibration Digest, Vol. 35, pp. 451-463.   DOI   ScienceOn
12 Park, S., Lee, J.J., Inman, D.J. and Yun, C.B. (2007). "Electro-mechanical Impedance-based Wireless Structural Health Monitoring Using PCA and k-means Clustering Algorithm", Journal of Intelligent Material Systems and Structures, Vol. 19, pp. 509-520.   DOI   ScienceOn
13 Bhalla, S., Naidu, A.S.K. and Soh, C.K. (2002). "Influence of Structure-actuator Interactions and Temperature on Piezoelectric Mechatronic Signatures for NDE", ISSS-SPIE Int,l Conferences on Smart Materials Structures and Systems, Bangalore.