Abstract
In order to minimize the impact on the structure during an internal explosion, the explosives storage must be kept at a distance from the inner wall to prevent the sympathetic detonation of the others explosives in an unexpected explosion. For safe explosives storage, a gap test was conducted by simulating the split arrangement of explosives inside the storage. In this study, the separation distance and arrangement between the emulsion explosives were applied differently to be sympathetic detonation at 2D of diameter and non-detonated at 2.5D. Considering the coefficient of detonation transmission and the size of the explosives storage, the explosive amount of 3kg was set, and most of the gap tests according to various arrangement changes were non-detonated, and safety was confirmed when applying the batch.
Keywords
Explosives Storage; Sympathetic detonation; Coefficient of Detonation Transmission; non-detonation; Emulsion Explosive;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김희창, 1995, 함수폭약(含水爆藥)에 대한 소고 - 원료 및 제품의 특성을 중심으로, 한국화학공학회, Vol. 13, No. 5, pp. 501-504.
2 윤철헌, 기경철, 1994, (최신)화약발파해설, 歐美書館, 서울.
3 정승원, 김정규, 김준하, 김남수, 김종관, 2022, 수치해석을 통한 화약류 간이저장소의 방폭성 및 구조인자 평가연구, 터널과 지하공간, Vol. 32, No. 2, pp. 160-172.
4 (주)한화, 2022, 산업용화약 제품설명서.