Browse > Article

A Survey on the Magnitude of the Sound, Ground Vibration and Properly Delayed Interval of a Plasma Rock-Splitting Machine driven by Electric Shocks  

Won, Yeon-Ho (원앤비 기술사사무소)
Kang, Choo-Won (조선대학교 공과대학 에너지 자원공학과)
Kim, Il-Jung (앤-토비 기술사사무소)
Publication Information
Explosives and Blasting / v.27, no.1, 2009 , pp. 7-20 More about this Journal
Abstract
In this study, 5 steps of different delay intervals are applied to a plasma rock-breaking machine that is driven by electric shocks in order to improve the workability of the traditional single-shot type plasma rock-breaking operation. The sequential steps use the electrolyte volume per delay of 1, 2, 3, 4, 5 kg and it has been analyzed to measure the delay time and level of the ground vibration and noise according to exploding. The delay time of the rock-breaking machine by an electric shock of 5 steps has used about 40~50ms at the electrolyte connected from 1 to 3 holes, about 70~80ms at the electrolyte connected from 4 to 5 holes. It is identified that the extents of the ground vibration is low to 1 over 3~6 compared with that of the emulsion explosives.
Keywords
Plasma; Delay time; Rock-breaking machine by an electric shock; Emulsion explosive;
Citations & Related Records
연도 인용수 순위
  • Reference
1 건설교통부, 2006, 도로공사 노천발파 설계 시공지침, 건설교통부, p. 11
2 정일록, 1999, 소음진동학, 신광문화사, 서울, pp. 262- 272
3 (주)록스코리아, 2008, 칼막플라즈마 암파쇄에 적용한 전력충격기의 적정 지발시차 및 암파쇄 검토보고서, pp. 25-33
4 양형식, 1992, 발파진동학, 구미서관, 서울, p. 109
5 기경철, 김일중, 2002, 산학인을 위한 발파공학, 동화기술, 서울, p. 317