Abstract
To examine the compression properties of structural members, the compression and bearing tests were conducted in parallel- and perpendicular-to-grain loading using domestic Japanese larch (Larix kaempferi (Lamb.) Carriere). Compression (bearing) properties with the length of a specimen and the contact length of the bearing plate were investigated, and deformations at each specimen length from the point of bearing force were measured to evaluate the effective end distance tabulated in the present practice (Korean Building Code). Compression (bearing) properties varied with the size of the bearing plate, and the end distance for dowel-type fastener taken into consideration of the specimen's deformation, for the safe design, should be applied with over 7 D.
Keywords
compression; bearing; Japanese larch; end distance; dowel-type fastener;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 小松幸平. 1989. 集成材骨組構造の解析(第2報). 木材學會誌. 35(3) : 201-211.
2 Sawata, K. and M. Yasumura. 2002. Ddetermination of embedding strength of wood for dowel-type fasteners. J. Wood Sci. 48 : 138-146.   DOI   ScienceOn
3 川元紀雄, 金山紀行. 1991. 横壓縮を受ける木材の弾性変形ー材長, 材せい, 加壓板長さが部分横壓縮に及ぼす影響. 木材學會誌. 37(1) : 16-23.
4 原田眞樹, 林 知行, 輕部正彦, 土田博澄, 図師明弘, 小松幸平. 2000. ドリフトピンを用いた集成材の面壓試驗. 材料. 49(4) : 368-372.
5 American Institute of Timber Construction. 1985. Timber Construction Manual, John Wiley & Sons, pp. (5-154)-(5-155).
6 Awaludin, A., W. Smittakorn, T. Hirai, and T. Hayashikawa. 2007. Bearing properties of Shorea obtusa beneath a laterally loaded bolt. J. Wood Sci. 53 : 204-210.   DOI
7 EN 1995-1-1. 2004. Eurocode 5 ; Design of timber structures Part 1-1.
8 Hoffmeyer, P., L. Damkilde, and T. N. Pedersen. 2000. Structural timber and glulam in compression perpendicular to grain. Holz als Rohund Werkstoff. 58 : 73-80.   DOI
9 Hwang, K. and K. Komatsu. 2002. Bearing properties of engineered wood products I; Effects of dowel diameter and loading direction. J. Wood Sci. 48(4) : 295-301.   DOI   ScienceOn
10 Kim, G. C. and J. J. Lee. 2000. Analysis of the behavior of bolt jointed wood connections by applying semi-rigid theory. Mokkchae Konghak. 28(4) : 72-82.
11 Kuenzi, E. W. 1955. Theoretical design of a nailed or bolted joint under lateral load. Forest Prod. Lab., USDA, Report No. D1951.
12 Yasumura, M., T. Murota, and H. Sakai. 1987. Ultimate properties of bolted joints in glued laminated timber, Proceeding of CIB-W18, 20-7-3.
13 김정환, 이원희. 2001. 소나무재의 휨 가공성에 미치는 섬유경사각의 영향. 목재공학. 29(2) : 118-125.
14 대한건축학회. 2005. 건축구조설계기준 및 해설.
15 平井卓郎, 金山紀行. 1982. 側材に木材を用いたボルト接合部のせん斷耐力ー荷重が材軸方向に作用する場合. 木材學會誌. 28(11) : 695-698.
16 한국표준협회. 2004. 목재의 압축 시험 방법. KS F 2206.
17 장상식. 2000. 함수율과 섬유경사각이 목재의 압축강도 및 초음파 전달속도에 미치는 영향. 목재공학. 28(2) : 10-18.
18 黃權煥, 小松幸平. 2003. SCLを鋼板挿入ドリフトピンで接合した接合部のセン斷性能. 木材學會誌. 49(4) : 275-286.
19 Oh, S. C. 2003. Evaluation of dowel bearing strength of structural composite lumber (SCL) on the effect of moisture content. Mokkchae Konghak. 31(3) : 61-69.
20 日本建築學會. 2006. 木質構造設計規準.同解説-ー許容応力度.許容耐力設計法.
21 임업연구원. 1994. 한국산 주요목재의 성질과 용도. 연구자료 제95호.
22 한국표준협회. 2001a. 목재의 밀도 및 비중 측정 방법. KS F 2198.
23 한국표준협회. 2001b. 목재의 함수율 측정 방법. KS F 2199.
24 한국표준협회. 2002. 목재 및 목질 제품의 지압 시험 방법. KS F 2156.