Abstract
Purpose: Hypovolemia is not uncommon among trauma patients in the emergency department (ED). Successful resuscitation of a hypovolemic patient often requires rapid intravenous administration of massive amounts of fluid. A rapid fluid infuser is used in the ED for this purpose, there have been no studies of their clinical uses and effectiveness. We studied clinical experience with a rapid fluid infuser at an urban university hospital in Seoul, Korea. Methods: We reviewed the medical records of 38 patients admitted to the ED with a history of application of a rapid fluid infuser from January 2004 to July 2005. Adult trauma patients older than 15 years of age were included in this study. Clinical data on the patients and the volume of fluid used to achieve a stable blood pressure were extracted from their medical records. Results: The total number of adult trauma patients with a history of application of a rapid fluid infuser from January 2004 to July 2005 in the ED was 16. The mean systolic blood pressure for deciding to apply the rapid fluid infuser was $74.9{\pm}12.7mmHg$. The mean time and volume used to achieve a stable blood pressure were 40.4 min and$2947.3{\pm}1339.2ml$, respectively. In all patients, the amount of fluid infused before using the rapid fluid infuser was between 500 ml and 10,000 ml, compared to 1,000 ml and 6,200 ml with the rapid fluid infuser. The mean amount of fluid per min. via the rapid fluid infuser was 85.5 ml. Vital signs were stabilized in 11 patients, 6 of the 11 were discharged alive. Conclusion: The mean amount of fluid delivered per min. via the rapid fluid infuser was much less than expected; thus, there should be clinical guidelines on volume resuscitation with a rapid fluid infuser in the ED. In the future, prospective, multicenter, clinical-data collection is needed for a more sophisticated study.
Keywords
Trauma; Hypovolemia; Shock; Infusion pump;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Iserson KV, Reeter AK: Rapid fluid replacement: a new methodology. Ann Emerg Med 1984:13:97-100   DOI   ScienceOn
2 Rackow EC, Falk JL, Fein IA, Siegel JS, Packman MI, Haupt MT et al.:Fluid resuscitation in circulatory shock: a comparison of the cardiorespiratory effects of albumin, hetastarch, and saline solutions in patients with hypovolemic and septic shock. Crit Care Med 1983:11:839-50   DOI   ScienceOn
3 Erstad, BL, Gales, BJ, Rappaport, WD. The use of albumin in clinical practice. Arch Intern Med 1991;151:901   DOI   ScienceOn
4 Bunn, F, Alderson, P, Hawkins, V. Colloid solutions for fluid resuscitation. Cochrane Database Syst Rev 2001;CD001319
5 Alderson, P, Schierhout, G, Roberts, I, et al. Colloids versus crystalloids for fluid resuscitation in critically ill patients. Cochrane Database Syst Rev 2000;CD000567
6 Judith E. Titnalli, Gabor D. Kelen, J. Stephan Stapczynski.: Emergency medicine. 6th ed. McGraw-Hill: 2004:1539-40
7 Iserson KV, Reeter AK: Comparision of flow rates for standard and large-bore blood tubing. West J Med 1985:183-5
8 Department of health and human services. Public use data tape: 1995
9 Stern SA, Dronen SC, Wang X.: Multiple resuscitation regimens in a near-fatal porcine aortic injury hemorrhage model. Acad Emerg Med 1995:2:89-97   DOI   ScienceOn
10 Schierhout, G, Roberts, I. Fluid resuscitation with colloid or crystalloid solutions in critically ill patients: A systematic review of randomised trials. BMJ 1998;316:961   DOI
11 James R. Roberts, Jerris R.Hedges.: Clinical procedures in emergency medicine. 4th ed. Saunders 2004:457
12 Iserson KV, Reeter AK: Rapid fluid replacement for severe hypovolemia-Human subject trials. West J Med 1987 :146:313-5
13 Millikan JS, Cain TL, Hansbrough J.: Rapid volume replacement for hypovolemic shock: a comparision of techniques and equipment. J Trauma 1984:24:428-31   DOI
14 Sandra L. Barcelona, Fatima Vilich, Charles J. Cot, et al. A comparision of flow rates and warming capabilities of the Level 1 and Rapid infusion system with various-size intravenous catheters. Anesth Analg 2003;97:358-63   DOI   ScienceOn
15 Fingerhut LA, Warner M: Injury chartbook. Health, Unted states, 1996-97
16 Weaver, DW, Ledgerwood, AM, Lucas, CE, et al. Pulmonary effects of albumin resuscitation for severe hypovolemic shock. Arch Surg 1978;113:387   DOI   ScienceOn
17 Finfer, S, Bellomo, R, Boyce, N, et al. A comparison of albumin and saline for fluid resuscitation in the intensive care unit. N Engl J Med 2004;350:2247   DOI
18 Wilkes, MM, Navickis, RJ. Patient survival after human albumin administration. A meta-analysis of randomized, controlled trials. Ann Intern Med 2001;135:149   DOI   ScienceOn
19 William H. Bickell, Matthew J. Wall, Paul E. Pepe, R. Russell Martin, Victoria F. Ginger, Mary K. Allen et al.: Immediate versus delayed fluid resuscitation for hypotensive patients with penetrating torso injuries. N Engl J Med 1994:331:1105-1109   DOI   ScienceOn
20 Bickwell WH, Bruttig SP, Millnamow GA, O'Benar J, Wade CE.: The detrimental effects of intravenous crystalloid after aortotomy in swine. Surgery 1991:110:529-36
21 Choi, PTL, Yip, G, Quinonez, LG, Cook, DJ. Crystalloids vs. colloids in fluid resuscitation: A systematic review. Crit Care Med 1999;27:200   DOI   ScienceOn
22 Judith E. Titnalli, Gabor D. Kelen, J. Stephan Stapczynski.:Emergency medicine. 6th ed. McGraw-Hill: 2004:229
23 Virgilio, RW, Rice, CL, Smith, DE, et al. Crystalloid vs. colloid resuscitation: Is one better? Surgery 1979;85:129