Abstract
In this research, aluminum composite panels of the general materials and fire retardant materials as building claddings make researches about fire performance comparison analysis. Test methods of the small and medium cone calorimeter experiments and SBI (Single Burning Item) experiments was applied to the determination. As a result, in the experiments peak heat release rate cone calorimeter the general aluminum composite panel $1,293kW/m^2$ ($75kW/m^2$), flame-retardant aluminum composite panel $70kW/m^2$ ($75kW/m^2$) was measured. In the SBI experiments fire growth rate the general fire aluminum composite panel is approximately 743 W/s and the flame-retardant aluminum composite panel is approximately 97 W/s of the value were measured. Thus, a standards enactment are urgently required in this case it is used as building claddings of the aluminum composite panel by fire risk assessment.
Keywords
Exterior fire; Vertical flame; Aluminum composite panel; Cone calorimeter test; SBI (Single Burning Item);
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 S.H. Min, M.S. Kim, Y.J. Jang, J.C. Sa, Y.J. Bae, and J.M. Lee, "A Study on the Development of a Head for Prevent the Fire Spread of Exterior", J. of Korea Institute of Fire Sci. & Eng., Vol.26, No.1, pp.113-119(2012).   과학기술학회마을   DOI   ScienceOn
2 S.H. Min, J.E. Yun, J.S. Sun, S.H. Jeong, C.H. Chea, and S.J. Kim, "Research for the Configuration of the Outside Sprinkler System", J. of Korea Institute of Fire Sci. & Eng., Vol.26, No.1, pp.102-112(2012).   과학기술학회마을   DOI   ScienceOn
3 Ministry of Land, Transport and Maritime Affairs No.2009-866(2009).
4 http://www.fpn119.co.kr/data/fpn119_co_kr, FirePrevention News, No.541.(2010).
5 S.H. Min and J.E. Yun, "A Study on the Modeling Vertical Spread Fire of Exterior Panel by Fire Dynamic Simulation (FDS)", J. of the Korea Safety Management & Science, Vol.11 No.2, pp.77-85 (2009).   과학기술학회마을
6 S.H. Min, J.E. Yun, M.S. Kim, and S.B. Choi, "A Study on the Fire Characteristics of Aluminum Composite Panel by Large Scale Calorimeter", J. of Korea Institute of Fire Sci. & Eng., Vol.24, No.2, pp.89-96(2010).   과학기술학회마을
7 J.E. Yun, "A Study on the Upper Combustion Expansion of Aluminum Composite Panel by Fire", Kyungwon University of Master's thesis(2009).
8 S.H. Min and M.S. Kim, "A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test", J. of the Korea Safety Management & Science, Vol.12, No.1, pp.1-9 (2010).   과학기술학회마을
9 K.W. Park and H.S. Im. etc., "Study on Correlation between Flashover and Smoke Production Rate in Real Scale Reaction-to-fire Test", J. of Korea Institute of Fire Sci. & Eng., Vol.23, No.2, pp.289- 296(2009).