Abstract
Hot smoke test is done in a subway tunnel. Alcohol trays of 1.0 MW and smoke generators are used for generating hot smoke. The fans equipped with the tunnel are successively run 9 min after smoke generation. It is verified how hot smoke is controlled by fans. Velocity and direction of flow, temperature and smoke density are measured and analyzed for smoke control performance of the tunnel with fans and analyzed from the fire-safety-point of view. Velocity of smoke flow is obtained by using measured velocity and temperature at the ceiling of the tunnel. The time when smoke-control flow is builded up is different for the different positions. Velocity distributions at various positions will be used for the boundaries and the comparison data in numerical simulations for evaluation on smoke-control facilities of subway tunnel.
Keywords
Hot smoke test; Subway tunnel;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 박원희, 장희철, 김동현, 김태국, "지하철 역사 승강장 화재발생시 열/연기 거동 분석을 위한 실험 및 수치 연구 (I) -실험적 접근-", 한국화재소방학회 논문지, Vol.20, No.3, pp.9-14(2006).
2 http://www.smokemachines.net/buyvicount compacts.html.
3 S. Sardqvist, "Initial Fires", Lund University(1993).
4 H. Ingason and Y.Z. Li, "Model Scale Tunnel Fire Tests with Longitudinal Ventilation", Fire Safety Journal, Vol.45, No.6-8, pp.371-384(2010).   DOI   ScienceOn
5 R.O. Carvel, A.N. Beard and P.W. Jowitt, "The Effect of Forced Longitudinal Ventilation on a Pool Fire in a Tunnel", Interflam '99, 8th International Fire Science & Engineering Conference, Edinburgh, Scotland, pp.1267-1272(1999).
6 R.O. Carvel, A.N Beard and P.W. Jowitt, "The Influence of Longitudinal Ventilation Systems on Fires in Tunnels", Tunnelling and Underground Space Technology, Vol.16, pp.3-21(2001).
7 D.H. Kim and W.H. Park, "Experiment by Using Reduced Scale Models for the Fire Safety of a Rescue Station in Very Long Tunnel in Korea", Tunnelling and Underground Space Technology, Vol.21, No.3-4, p.303(2006).   DOI   ScienceOn
8 국토해양부, "철도시설 안전세부기준"(2008).
9 국토해양부, "철도시설 안전세부기준"(2008).
10 국토해양부, "도시철도 건설규칙"(2008).