Abstract
In this paper, we conducted experiments on damaged patterns of incandescent lamps by external stress, such as external flame or external impact. Glass bulbs were melted and filaments were evaporated by external flame when the bulbs were lit, and finally molten marks were recognized at the filaments. Also, there were some differences in absorption patterns of evaporated filament elements according to set-up directions, and evaporated filament elements were absorbed in lead-in wires, support, inside of glass. In case the bulbs were lit and they were damaged by external impacts, filament burned out. Filaments were not evaporated but melted. We expect that this results could be used to judge whether electric current flew through incandescent lamps or not in fire site.
Keywords
Incandescent lamp; Flame and impact; Fire investigation; Damaged patterns; SEM;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 消防科學總合Center, "火災原因調査要領(電氣火災編)", pp.131-137, 三州社(1997)
2 東京消防廳, "新火災調査敎本-第3卷 電氣火災編", 東京防災指導協會, pp.187-194(2007)
3 東京消防廳, "電氣火災 -原因の鑑識-", pp.111 -117, 全國加除法令出版(1974)
4 최충석, 김현우, 이경섭, 이춘하, 임양수, 정재희, "전기화재공학", pp.376-379, 동일출판사(2004)
5 이재국, 김진우, 신재철, 김명수, "텅스텐 백열전구의 필라멘트 단선에 의한 가속수명시험", 대한기계학회 논문집 A권, Vol.29, No.7, pp.921-929(2005)
6 John D. Dehaan, "Kirk's Fire Investigation", BRADY, pp.153-155(2002)
7 김만건, 김진표, "전기화재 감식공학", pp.251- 255, 성안당(2006)
8 송길목, 한운기, 김영석, 최충석, "220V/100W 백열전구의 온도특성에 따른 화재분석에 관한 연구", 한국화재소방학회논문지, Vol.20, No.1, pp.43-49(2006)   과학기술학회마을
9 지철근, "최신전기응용", pp.24-30, 문운당(2008)