Browse > Article
http://dx.doi.org/10.14579/MEMBRANE_JOURNAL.2015.25.3.239

Effects of Interferents in Blood on the Blood Glucose Measurements by Using the New Type of Phosphazene Diagnostic Membranes  

Kwon, Suk-Ky (Department of Biological and Chemical Engineering, Hongik University)
Publication Information
Membrane Journal / v.25, no.3, 2015 , pp. 239-247 More about this Journal
Abstract
The new types of phosphazene diagnostic membranes have been prepared for blood glucose measurements. The possible interferents in human blood were sorted into 4 different series and their effects on the glucose measurements were examined. In case of series I which indicates the lowest concentration, most of them did not show any serious effects on the blood glucose measurements, but only ascorbic acid (AA) showed 5~8% higher values compared to K/S values of the standard solution. In case of series II, all of four interferents showed 3~4% lower K/S values than those of plasma, but they showed consistent values by concentration variation. In case of series III, all of three interferents did not show any big differences compared to the standard solution. In case of series IV which indicates the highest concentration, two interferents showed 11~15% lower K/S values than the standard values, however they did not any serious effect on the blood glucose measurements.
Keywords
phosphazene; membranes; diabetes; glucose; measurements; interferents;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 Y. Cho, "Diabetes, as much as know that look", Miraejysik, Seoul (2006).
2 Home Health Management Research Institute, "Diabetes", Kumyoung, Seoul (1992).
3 Seoul National University Hospital, "A guide for diabetes management", Bummoon education, Seoul (2012).
4 Y. Kim, "Diabetes treatment", Medbook, Seoul (2012).
5 T. Asano and T. Norioka, "Diabetes", Nihon Bungeisha, Tokyo (2000).
6 K. Huh, "Diabetic health", D and C Media, Seoul (2006).
7 S. Kim, "Life guide for diabetes control", Hyoseong, Seoul (1993).
8 T. Asano, "Diabetic food and life style", Shufu-To-Seikatsusha Co., Tokyo (2005).
9 J. Kim, "Diabetes: Diagnostics and control", Ohsung, Seoul (1997).
10 S. Kwon and M. Choi, "The preparation of polyacrylonitrile diagnostic membranes for blood glucose measurements (2): Effects of blood constituens on the measurements of glucose concentration", Membr. J., 18, 4 (2008).
11 S. Kwon and J. Yu, "The preparation of polyacrylonitrile diagnostic membranes for blood glucose measurements (3): Effects of storage environments on the measurements of glucose concentration", Membr. J., 19, 3 (2009).
12 S. Kwon, "Preparation of polyurethane diagnostic membranes for blood glucose measurements (6): Effects of hematocrit on the measurements of glucose concentration", Membr. J., 20, 3 (2010).
13 S. Kwon, "Studies on the polyurethane diagnostic membrane for diabetes (2): Effects of additives in membrane formulations for the measurement of urine glucose", Polymer (Korea), 18, 6 (1994).
14 S. Kwon, I. Park, and D. Yoon, "The preparation of polyacrylonitrile diagonostic membranes for blood glucose measurements (1): Effects of temperature and humidity on the measurements of glucose concentration", Membr. J., 17, 4 (2007).
15 R. P. Back, "Biosensor technology", Marcel Dekker, New York (1990).
16 S. Kwon, "Studies on the preparation of diagnostic membranes for blood glucose measurements (2): Effects of temperature on the measurements of glucose concentration", Hongik Industrial Technology, 13, 551 (2003).
17 R. E. Kesting, "Synthetic polymeric membranes", Wiley-Interscience, New York (1985).
18 M. Gordon, "Polymer membranes", Springer-Verlag, New York (1985).
19 S. Kwon, "Basic studies on the preparation of diagnostic membranes by using multi-layered gelatin films to measure blood glucose level of diabetics", Membr. J., 8, 1 (1998).
20 S. Kwon, "Studies on the muti-layered gelatin diagnostic membranes for diabetes (2): Effects of interferents in blood on the diffusion-controlled rates of glucose", Membr. J., 9, 4 (1999).
21 S. Kwon, "Studies on the preparation of diagnostic membranes for blood glucose measurements (1): Model experiments by using microporous polyurethane membrane", Hongik Industrial Technology, 12, 717 (2002).
22 H. R. Allcock, M. Gebura, S. Kwon, and T. X. Neenan, "Amphiphilic polyphosphazenes as membrane materials: Influence of side group on radiation crosslinking, semipermeability, and surface morphology", Biomaterials, 9, 500 (1988).   DOI
23 S. Kwon, "A study on the preparation of polyurethane diagnostic membrane for urine glucose test", J. Kor. Ind. & Eng. Chem., 5, 6 (1994).
24 S. Kwon, I. Park, and D. Yoon, "Studies on the preparation of polyurethane diagnostic membranes for blood glucose measurements (5): Effects of temperature and humidity on the measurements of glucose concentration", Membr. J., 17, 1 (2007).
25 S. Kwon and C. Jun, "Studies on polyphosphazenes- bound Wittig reactions", J. of Korean Ind. & Eng. Chem., 5, 5 (1994).
26 H. R. Allcock and S. Kwon, "Hydrophilic polyphosphazenes as hydrogels: Radiation crosslinking and hydrogel characteristics of poly[bis(methoxyethoxy) phosphazene]", Biomaterials, 7, 6 (1986).
27 S. Kwon and B. Lee, "A study on the preparation of metal-ion separation membrane with hydrophilic polyphosphazene", J. of Korean Ind. & Eng. Chem., 10, 3 (1999).
28 S. Kwon and B. Lee, "A Study on the preparation of ion-exchange membranes with polyphosphazenes", J. of Korean Ind. & Eng. Chem., 9, 3 (1998).
29 S. Kwon, "Effects of testing and storage environments on the blood glucose measurements by using phosphazene diagnostic membranes", Membr. J., 22, 5 (2012).
30 S. Kwon, "Effects of interferents in blood on the blood glucose measurements by using polyphosphazene diagnostic membranes" Membr. J., 23, 4 (2013).
31 H. R. Allcock and S. Kwon, "Covalent linkages of proteins to surface-modified poly(organophosphazenes): Immobilization of glucose-6-phosphate dehydrogenase and trypsin", Macromolecules, 19, 1502 (1986).   DOI
32 S. Kwon, "Preparation of phenoxy-methylamino cosubstituted polyphosphazene diagnostic membranes for bllod glucose measurement", Membr.J., 24, 4 (2014).