Browse > Article

The Preparation of Polyacrylonitrile Diagnostic Membranes for Blood Glucose Measurements (1) : Effects of Temperature and Humidity on the Measurements of Glucose Concentration  

Kwon, Suk-Ky (Dept. of Chemical System Engineering, Hongik University)
Park, In-Hee (Dept. of Chemical System Engineering, Hongik University)
Yoon, Do-Young (Dept. of Chemical System Engineering, Hongik University)
Publication Information
Membrane Journal / v.17, no.4, 2007 , pp. 369-374 More about this Journal
Abstract
Polyacrylonitrile diagnostic membranes were prepared to measure blood glucose level of diabetics. Final absorbances at 680 nm through activated polyacrylonitrile membranes were measured at various concentration of glucose in plasma. The end-point results of K/S values obtained from the absorbances had a linear relationship toward the glucose concentration. The effect of temperature on the measurements of glucose concentration was studied. The stability of polyacrlonitrile diagnostic membranes was examined at RH 80%.
Keywords
polyacrylonitrile; membranes; diabetics; glucose concentration;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 S. Kwon, 'Studies on the preparation of diagnostic membranes fir blood glucose measurements (1): model experiments by using microporous polyurethane membranes', Hongik Industrial Technology, 12 (2002)
2 S. Kim, 'Life Guide for Diabetes Control', Hyoseong, Seoul (1993)
3 W. Hong. 'Oriental Treatment for Modern Disease', Hyoseong, Seoul (1993)
4 D. Kang, 'Physiology', Shinkwang, Seoul (1988)
5 M. Jain and R. Wagner, 'Introduction to Biological Membranes', Wily, New York (1980)
6 A. Y. Coran and R. Patel, Rubber Chem. Technol., 53(4), 781 (1980)   DOI   ScienceOn
7 D. Jung, 'Health Control for Modern People', Ohchon, Seoul (1993)
8 S. Kwon, 'Studies on the preparation of diagnostic membranes for blood glucose measurements (4): effects of additives in blood on the measurements of glucose concentration', Hongik Industrial Technology, 15 (2005)
9 S. Kwon, 'A study on the preparation of polyurethane diagnostic membrane for urine glucose test', J. Kor. Ind. & Eng. Chem., 5, 6 (1994)
10 S. Kwon, 'Studies on the preparation of diagnostic membranes for blood glucose measurements (3): effects of hematocrit on the measurements of glucose concentration', Hongik Industrial Technology, 14 (2004)
11 S. Kwon, 'Basic studies on the preparation of diagnostic membranes by using multi-layered gelatin films to measure blood glucose level of diabetcs', Membrane J., 8, 1 (1998)
12 S. Kwon, 'Studies on the muti-layered gelatin diagnostic membranes for diabetes (2): effects of interferents in blood on the diffusion-controlled rates of glucose', Membrane J., 9, 4 (1999)
13 R. E. Kesting, 'Synthetic Polymeric Membranes', Wiley, Interscience, New York (1985)
14 M. Gardon, 'Polymer Membranes', Springer-Verlag, New York (1985)
15 Home Health Management Research Institute, 'Diabetes', Kumyoung, Seoul (1992)
16 K. Lee, 'Modern Disease Digest', Kuckminilbosa, Seoul (1992)
17 J. Kim, 'Diabetes: Diagnostics and Control', Ohsung, Seoul (1997)
18 S. Kwon and B. Lee, 'Studies on the multi-layered gelatin diagnostic membranes for diabetes (1): effects of temperature and humidity', Membrane J., 9, 2 (1992)
19 S. Kwon, 'Studies on the preparation of diagnostic membranes for blood glucose measurements (2): effects of temperature on the measurements of glucose concentration', Hongik Industrial Technology, 13 (2003)
20 D. T. Plummer, 'An Introduction to Practical Biochemistry', McGraw-Hill, London (1978)
21 H. V. Bergmeyer, 'Methods of Enzymatic Analysis', VCH, Weinheim (1981)
22 R. P. Back, 'Biosessor Technology', Marcel Deckker, New York (1990)
23 S. Kwon, I. Park, and D. Yoon, 'Studies on the preparation of polyurethane diagnostic membranes for blood glucose measurements (5): effects of temperature and humidity on the measurements of glucose concentration', Membrane J., 17, 1 (2007)   과학기술학회마을
24 S. Kwon, 'Studies on the polyurethane diagnostic membrane for diabetes (2): effects of additives in membrane formulations for the measurement of urine glucose', Polymer (Korea), 18, 6 (1994)