Browse > Article
http://dx.doi.org/10.5139/IJASS.2009.10.2.043

Calibration of a Five-Hole Multi-Function Probe for Helicopter Air Data Sensors  

Kim, Sung-Hyun (Department of Mechanical and Aerospace Engineering, Gyeongsang National University)
Kang, Young-Jin (Department of Mechanical and Aerospace Engineering, Gyeongsang National University)
Myong, Rho-Shin (Department of Mechanical and Aerospace Engineering, Gyeongsang National University)
Cho, Tae-Hwan (Department of Mechanical and Aerospace Engineering, Gyeongsang National University)
Park, Young-Min (Subsystem Department, Korea Aerospace Research Institute)
Choi, In-Ho (Subsystem Department, Korea Aerospace Research Institute)
Publication Information
International Journal of Aeronautical and Space Sciences / v.10, no.2, 2009 , pp. 43-51 More about this Journal
Abstract
In the flight of air vehicles, accurate air data information is required to control them effectively. Especially, helicopters are often put in drastic motion involved with high angle of attacks in order to perform difficult missions. Among various sensors, the multi function probe (MFP) has been used in the present study mainly owing to its advantages in structural simplicity and capability of providing various information such as static and total pressure, speed, and pitch and yaw angles. In this study, a five-hole multi-function probe (FHMFP) is developed and its calibration is conducted using multiple regressions. In this work a calibration study on the FHMFP, an air data sensor for helicopters, is reported. It is shown that the pitch and yaw angles' accuracy of calibration is ${\pm}0.91^{\circ}$ at a cone angle of $0^{\circ}{\sim}30^{\circ}$ and ${\pm}2.0^{\circ}$ at $30^{\circ}{\sim}43^{\circ}$, respectively, which is summarized in table 3.
Keywords
five-hole multi-function probe(FHMFP); air data sensor; calibration; multiple regressions;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 S.K.S. Boetcher, E.M. Sparrow, "Limitations of the standard Bernoulli equation method for evaluating Pitot/impact tube data”, Int. J. of Heat and Mass Transfer, Vol. 50, pp. 782-788. 2007.   DOI   ScienceOn
2 "FLUENT User’s Guide”, FLUENT Inc., 1998.
3 G.L. Morrison, M.T. Schobeiri, and K.R. Pappu, “Five-hole pressure probe analysis technique”, Flow Measurement and Instrumentation 9, 153-158, 1998.   DOI   ScienceOn
4 S.W. Lee and T.J. Yoon, “Experiment investigation of flow parameters influencing the calibration of five-hole probes”, The Korean Society of Mechanical Engineers, Vol. 21, No.5, pp.637-649, 1997.
5 R.H. Wickens and C.D. Williams, “Calibration and use of five-hole flow direction probes for low speed wind tunnel application”, National Research Council Canada, Aeronautical note, 1985.
6 S.Y. Oh, S.K. Ahn and C.Y. Cho, “Calibration of a five-hole pressure probe using a single sector error interpolation model”, The Korean Society for Aeronautical and Space Sciences, Vol. 34, No. 5, pp.30-38, 2006.   DOI   ScienceOn
7 D.J. Kim, Y.S. Cheon, R.S. Myong, C.W. Park, T.H. Cho, Y.M. Park and I.H. Choi, “Design of pitot-tube configuration using CFD analysis and optimization techniques”, The Korean Society of Mechanical Engineers , Vol. 32, No.5, pp. 392-399, 2008.   DOI   ScienceOn
8 Gallington, G.G., “Measurement of very large flow angles with non-nulling sevenhole probes”, USAFA-TR-80-17, 1980.