Browse > Article

Railway System Standby Power Nickel Metal Hydride Battery  

Kim, Sung-Yong (우송대학교 철도차량시스템학과)
Park, Dong-Pil (서울산업대학교 에너지환경대학원 신에너지 공학과)
Publication Information
Journal of the Korean Society for Railway / v.12, no.6, 2009 , pp. 873-877 More about this Journal
Abstract
In order to use railway system standby power, produced 160Ah NiMH battery that would be able to substitute the lead acid battery or NiCd battery form which contain the toxic material in environment, using parallel connected 80Ah NiMH battery. And in order to develop proper electrode in the 160Ah NiMH battery, tested high rate discharge performance of the ternary electrolyte. 160Ah NiMH battery evaluated the various test in order to use railway system standby power.
Keywords
NiMH; Nickel Metal hydride battery; system standby power;
Citations & Related Records
연도 인용수 순위
  • Reference
1 松田好晴(1995), 竹原善一郞, 增補版, 電池便覽, pp.365-366, p.718
2 Linden/Reddy(2001), Handbook of batteries, 3rd edition., 22.12, 30.13
3 KSC8534(2005), pp.4-5