This paper presents a synchronous-reference-frame-based control of single-phase UPQC(Unified Power Quality Conditioner) to improve power quality in ac electrified railway systems. The proposed synchronous-reference-frame-based UPQC can compensate the voltage distortion, the voltage sag, the harmonic currents, and the reactive power instantaneously. The simulation results show that the UPQC can compensate the harmonic supply voltages, the voltage sag, the harmonic load currents, and the reactive power in electrified railway systems. Validity and effectiveness of the proposed UPQC control method based on the synchronous-reference-frame is illustrated through the simulation results.
Keywords
UPQC; power quality; AC electrified railway;
Citations & Related Records
연도 인용수 순위
  • Reference
1 S. Silva, B. Lopes, B. Cardoso, R. Campana anhd W. Boaventura(2004), "Performance Evaluation of PLL Algorithms for Single-phase Grid-connected Systems," IEEE IAC Proceedings, pp. 2259-2263
2 H. Morimoto, M. Ando, Y. Mochinaga, T. Kato, J. Yoshizawa, T. Gomi, T. Miyashita, S. Funahashi, M. Nishitoba and S. Oozeki(2002), "Development of Railway Static Power Conditioner used at Substation for Shinkansen", IEEE PCC Proceedings, pp. 1108-1111
3 M. Saitou, N. Matusi and T. Shimizu(2003), "A Control Strategy of Single-phase Active Filter Using A Novel d-q transformation," IEEE IAC Proceedings, pp. 1222-1227
4 S. Senini and P. Wolfs(2000), "Hybrid Active Filter for Harmonically Unbalanced Three Phase Three Wire Railway Traction Loads," IEEE Trans. on Power Electronics, vol. 15, no. 4, pp. 702-710   DOI   ScienceOn