Browse > Article
http://dx.doi.org/10.5090/jcs.21.148

The Impact of Intrapericardial versus Intrapleural HeartMate 3 Pump Placement on Clinical Outcomes  

Salna, Michael (Division of Cardiac, Thoracic, and Vascular Surgery, Department of Surgery, Columbia University Irving Medical Center)
Ning, Yuming (Center for Innovation and Outcomes Research, Department of Surgery, Columbia University Irving Medical Center)
Kurlansky, Paul (Division of Cardiac, Thoracic, and Vascular Surgery, Department of Surgery, Columbia University Irving Medical Center)
Yuzefpolskaya, Melana (Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center)
Colombo, Paolo C. (Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center)
Naka, Yoshifumi (Division of Cardiac, Thoracic, and Vascular Surgery, Department of Surgery, Columbia University Irving Medical Center)
Takeda, Koji (Division of Cardiac, Thoracic, and Vascular Surgery, Department of Surgery, Columbia University Irving Medical Center)
Publication Information
Journal of Chest Surgery / v.55, no.3, 2022 , pp. 197-205 More about this Journal
Abstract
Background: The integrated design of the HeartMate 3 (Abbott Laboratories, Chicago, IL, USA) affords flexibility to place the pump within the pericardium or thoracic cavity. We sought to determine whether the presence of a left ventricular assist device (LVAD) in either location has a meaningful impact on overall patient outcomes. Methods: A retrospective cohort study was conducted of all 165 patients who received a HeartMate 3 LVAD via a median sternotomy from November 2014 to August 2019 at our center. Based on operative reports and imaging, patients were divided into intrapleural (n=81) and intrapericardial (n=84) cohorts. The primary outcome of interest was in-hospital mortality, while secondary outcomes included postoperative complications, cumulative readmission incidence, and 3-year survival. Results: There were no significant between-group differences in baseline demographics, risk factors, or preoperative hemodynamics. The overall in-hospital mortality rate was 6%, with no significant difference between the cohorts (9% vs. 4%, p=0.20). There were no significant differences in the postoperative rates of right ventricular failure, kidney failure requiring hemodialysis, stroke, tracheostomy, or arrhythmias. Over 3 years, despite similar mortality rates, intrapleural patients had significantly more readmissions (n=180 vs. n=117, p<0.01) with the most common reason being infection (n=68/165), predominantly unrelated to the device. Intrapleural patients had significantly more infection-related readmissions, predominantly driven by non-ventricular assist device-related infections (p=0.02), with 41% of these due to respiratory infections compared with 28% of intrapericardial patients. Conclusion: Compared with intrapericardial placement, insertion of an intrapleural HM3 may be associated with a higher incidence of readmission, especially due to respiratory infection.
Keywords
Left ventricular assist device; Heart failure; Pleural space;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Boyd WD, Tyberg JV, Cox JL. A review of the current status of pericardial closure following cardiac surgery. Expert Rev Cardiovasc Ther 2012;10:1109-18.   DOI
2 Wachter K, Franke UF, Rustenbach CJ, Baumbach H. Minimally invasive versus conventional LVAD-implantation: an analysis of the literature. Thorac Cardiovasc Surg 2019;67:156-63.   DOI
3 Taghavi S, Ward C, Jayarajan SN, Gaughan J, Wilson LM, Mangi AA. Surgical technique influences HeartMate II left ventricular assist device thrombosis. Ann Thorac Surg 2013;96:1259-65.   DOI
4 Organ Procurement and Transplantation Network. Criteria requirements in adult heart allocation policy [Internet]. Richmond (VA): Organ Procurement and Transplantation Network; 2018 [cited 2020 Dec 22]. Available from: https://optn.transplant.hrsa.gov/learn/professional-education/adult-heart-allocation/.
5 Kazui T, Zhang A, Greenberg J, et al. Left ventricular assist device inflow angle and pump positional change over time adverse impact on left ventricular assist device function. Ann Thorac Surg 2016;102:1933-40.   DOI
6 Schmitto JD, Molitoris U, Haverich A, Strueber M. Implantation of a centrifugal pump as a left ventricular assist device through a novel, minimized approach: upper hemisternotomy combined with anterolateral thoracotomy. J Thorac Cardiovasc Surg 2012;143:511-3.   DOI
7 Kilic A, Ransom J, Maltais S, et al. Pump position impacts HeartMate II left ventricular assist device thrombosis. ASAIO J 2019;65:227-32.   DOI
8 Kaku Y, Naka Y, Witer L, et al. Late inflow or outflow obstruction requiring surgical intervention after HeartMate 3 left ventricular assist device insertion. Interact Cardiovasc Thorac Surg 2020;31:626-8.   DOI
9 Imamura T, Nguyen A, Chung B, et al. Association of inflow cannula position with left ventricular unloading and clinical outcomes in patients with HeartMate II left ventricular assist device. ASAIO J 2019;65:331-5.   DOI
10 Carrozzini M, Bejko J, Gerosa G, Bottio T. Bilateral mini-thoracotomy approach for minimally invasive implantation of HeartMate 3. Artif Organs 2019;43:593-5.   DOI
11 Adamson RM, Mangi AA, Kormos RL, Farrar DJ, Dembitsky WP. Principles of HeartMate II implantation to avoid pump malposition and migration. J Card Surg 2015;30:296-9.   DOI
12 Imamura T, Narang N, Nitta D, et al. Optimal cannula positioning of HeartMate 3 left ventricular assist device. Artif Organs 2020;44:e509-19.   DOI
13 Shih H, Butler C, Melehy A, et al. Serial assessment of HeartMate 3 pump position and inflow angle and effects on adverse events. Eur J Cardiothorac Surg 2021;59:1166-73.   DOI
14 LaRue SJ, Raymer DS, Pierce BR, Nassif ME, Sparrow CT, Vader JM. Clinical outcomes associated with INTERMACS-defined right heart failure after left ventricular assist device implantation. J Heart Lung Transplant 2017;36:475-7.   DOI
15 Lanfear AT, Hamandi M, Fan J, DiMaio JM, George TJ. Trends in HeartMate 3: what we know so far. J Card Surg 2020;35:180-7.   DOI
16 Gosev I, Wood K, Ayers B, et al. Implantation of a fully magnetically levitated left ventricular assist device using a sternal-sparing surgical technique. J Heart Lung Transplant 2020;39:37-44.   DOI
17 Kang G, Ha R, Banerjee D. Pulmonary artery pulsatility index predicts right ventricular failure after left ventricular assist device implantation. J Heart Lung Transplant 2016;35:67-73.   DOI