Browse > Article

Femoral Endarteritis as a Complication of Percutaneous Suture Closure Device -A case report-  

Hong, Joon-Hwa (Department of Cardiovascular and Thoracic Surgery, Ajou University Hospital)
Choi, Jin-Wook (Department of Cardiovascular and Thoracic Surgery, Ajou University Hospital)
Moon, Jong-Hwan (Department of Cardiovascular and Thoracic Surgery, Ajou University Hospital)
Soh, Dong-Moon (Department of Cardiovascular and Thoracic Surgery, Ajou University Hospital)
Publication Information
Journal of Chest Surgery / v.39, no.11, 2006 , pp. 864-867 More about this Journal
Abstract
Percutaneous suture closure device is known as relatively safe and convenient tool, which can decrease not only bed rest period of patient but also time consuming effort of manual compression of doctor after femoral artery puncture. However[C1], there are also some reports on complication of its use. We report a 62-year-old male patient who had femoral artery endarteritis[0] with pseudoaneurysm as a complication of percutaneous suture closure device after percutaneous coronary angiography[C2]. He was treated successfully by appropriate antibiotics and vessel reconstruction using autologous saphenous vein patch.
Keywords
Complication; Endarteritis; Femoral artery; Angioplasty, transluminal, percutaneous coronary;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Hollis HW Jr, Rehring TF. Femoral endarteritis associated with percutaneous suture closure: new technology, challenging complications. J Vasc Surg 2003;38:83-7   DOI   ScienceOn
2 Messina LM, Brothers TE, Wakefield TW, et al. Clinical characteristics and surgical management of vascular complications in patients undergoing cardiac catheterization: interventional versus diagnostic procedures. J Vasc Surg 1991;13:593-600   DOI
3 Tsuchikane E, Solomon LW, Fusman B, Jolly N, Kim A, Feldman T. Percutaneous suture closure for management of large French size arterial puncture in aortic valvuloplasty. J Invasive Cardiol 2001;13:592-6
4 Sprouse LR, Botta DM, Hamilton IN. The management of peripheral vascular complications associated with the use of percutaneous suture-mediated closure devices. J Vasc Surg 2001; 33:688-93   DOI   ScienceOn
5 Tolerico PH, McKendall GR. Femoral endarteritis as a complication of percutaneous coronary intervention. J Invasive Cardiol 2000;12:155-7
6 Geary K, Landers JT, FioreW, Riggs P. Management of infected femoral closure devices. Cardiovasc Surg 2002;10:161-3   DOI   ScienceOn
7 Gerckens U, Cattelaens N, Lampe EG, Grube E. Management of arterial puncture site after catheterization procedures: evaluating a suture-mediated closure device. Am J Cardiol 1999; 83:1658-63   DOI   ScienceOn
8 Wagner SC, Gonsalves CF, Eschelman DJ, Sullivan KL, Bonn J. Complications of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure: a casecontrolled study. J Vasc Interv Radiol 2003;14:735-41   DOI   ScienceOn