Browse > Article
http://dx.doi.org/10.14695/KJSOS.2016.19.3.81

Affecting Factor Analysis for Respiration Rate Measurement Using Depth Camera  

Oh, Kyeong-Taek (Department of Medical Engineering, Yonsei University College of Medicine)
Shin, Cheung-Soo (Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine)
Kim, Jeongmin (Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine)
Jang, Won-Seuk (Department of Medical Engineering, Yonsei University College of Medicine)
Yoo, Sun-Kook (Department of Medical Engineering, Yonsei University College of Medicine)
Publication Information
Science of Emotion and Sensibility / v.19, no.3, 2016 , pp. 81-88 More about this Journal
Abstract
The purpose of this research was to analyze several factors that can affect the respiration rate measurement using the Creative Senz3D depth camera. Depth error and noise of the depth camera were considered as affecting factors. Ambient light was also considered. The result of this study showed that the depth error was increased with an increase of the distance between subject and depth camera. The result also showed depth asymmetry in the depth image. The depth values measured in right region of the depth image was higher than real distance and depth values measured in left of the depth image was lower than real distance. The difference error of the depth was influenced by the orientation of the depth camera. The noise created by the depth camera was increased as the distance between subject and depth camera was increased and it decreased as the window size was increased which was used to calculate noise level. Ambient light seems to have no influence on the depth value. In real environment, we measured respiration rate. Participants were asked to breathe 20 times. We could find that the respiration rate which was measured from depth camera shows excellent agreement with that of participants.
Keywords
Affect Factor Analysis; Depth Camera; Depth Sensor; Non-contact; Respiration; Respiration Rate;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Cho, H. K., Lee, J. H., Lee, C. K., & Lee, M. H. (2006). An exploratory research for development of design of sensor-based smart clothing. Korean Journal of the Science of Emotion & Sensibility, 9(2), 141-150.
2 Cho, H. K. & Min, S. D. (2012). A study of the basic design for smart clothing based on measurement of the respiration. Korean Journal of the Science of Emotion & Sensibility, 15(4), 415-424.
3 Devis, D., Gilberto, G., Guido, L., Massimiliano, P., Carlo, A., Sergio, B., Gianna, C., Walter, C., Massimo, M., & Juri, L. D. (2009). Non-contact detection of breathing using a microwave sensor. Sensors, 9(4), 2574-2585.   DOI
4 Scopesi, F., Calevo, M. G., Rolfe, P., Arioni, C., Traggiai, C., Risso, F. M., & Serra, G. (2007). Volume targeted ventilation (volume guarantee) in the weaning phase of premature newborn infants. Pediatric Pulmonology, 42, 864-870.   DOI
5 Singh, A., Lubecke, V., & Boric-Lubecke, O. (2011). Pulse pressure monitoring through non-contact cardiac motion detection using 2.45 GHz microwave doppler radar. Engineering in Medicine and Biology Society, 2011 Annual International Conference of the IEEE (pp. 4336-4339).
6 Tahavori, F., Alnwaimi, B., Alnowami, M., Copland, M., & Wells, K. (2012). A quantitative assessment of using the kinect for xbox360 for respiratory surface motion tracking. SPIE, Medical Imaging, 8316, 83161T.
7 Yu, M. C., Liou, J. L., Kuo, S. W., Lee, M. S., & Hung, Y. P. (2012). Noncontact respiratory measurement of volume change using depth camera. Engineering in Medicine and Biology Society, 2012 Annual International Conference of the IEEE (pp. 2371-2374).
8 Creative Technology Ltd (2015). CREATIVE SENZ3D. Retrieved from November 10, 2015, http://asia.creative.com/p/web-cameras/creative-senz3d
9 Bernacchia, N., Scalise, L., Casacanditella, L., Ercoli, I., Marchionni, P., & Tomasini, E. P. (2014). Non contact measurement of heart and respiration rates based on kinect. Medical Measurements and Applications (MeMeA), 2014 IEEE International Symposium on IEEE (pp. 4-8).
10 Aliverti, A., Dellaca, R., Pelosi, P., Chiumello, D., Pedotti A., & Gatinoni, L. (2000). Opto-electronic plethysmography in intensive care patients. American Journal of Respiratory and Critical Care Medicine, 161, 1546-1552.   DOI