Browse > Article

Removal of Total Phosphate by Bipolar Packed Bed Electrolytic Cell  

Kim, Eun-Hee (Department of Environmental Engineering, Dong-A University)
Park, Seung-Cho (Department of Environmental Engineering, Dong-A University)
Publication Information
Applied Chemistry for Engineering / v.19, no.4, 2008 , pp. 366-369 More about this Journal
Abstract
To evaluate the performance of a bipolar packed bed cell (BPBC) filled with granular aluminium, the experiments were carried out in two groups as batch and continuous processes. In a batch process, removal efficiency of total phosphate (T-P) was 88% in case of electrolytic treatment of phosphate solution, T-P 10 mg/L at 6 V during 3 h by BPBC filled with granular aluminium. In a continuous process, residual T-P concentration was about 2 mg/L in case of electrolytic treatment of phosphate solution, 10 mg/L at 6 V, HRT 3 h by BPBC filled with granular aluminium. Break-through point was observed after running for 120 h at hydraulic retention time (HRT) of 3 h.
Keywords
bipolar packed bed electrolytic cell; granular aluminum; breakthrough point; hydraulic retention time (HRT);
Citations & Related Records

Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 APHA, AWWA, and WEF, Standard methods for the examination of water and wastewater, 19th ed. Washington D. C. (1995)
2 X, Chen, G. C. Chen, and P. L. Yue, Sep. Purif. Technol., 19, 65 (2000)   DOI   ScienceOn
3 S. Irdemez, N. Demircioglu, Y. S. Yildiz, and Z. Bingul, Separation and Purification Technology, 52, 218 (2006)   DOI   ScienceOn
4 O. Groterud and L. Smoczynski, Water Res. 20, 667 (1986)   DOI   ScienceOn
5 N. Adhoum, L. Monser, N. Bellakhal, and J.-E. Belgaied, J. of Hazardous, Materials, 112, 207 (2004)   DOI   ScienceOn
6 C. J. Yun, H. C. Yu, J. S. Kim, B. S. Lee, M. H. Kawk, and S. C. Park, KSEE, 26, 767 (2005)
7 B. S. Shin and J. W. Nam, Electrochemistry, Sae han publishing Company (1974)
8 J.-P. Boisvert, T. C. To, A. Berrak, and C. Jolicoeur, Water Res., 3, 1939 (1997)