Browse > Article
http://dx.doi.org/10.11112/jksmi.2016.20.1.064

An Evaluation of Flexural Performance of Composite Beam with Ultra High Performance Concrete Deck and Inverted T-Shaped Steel Girder  

Yoo, Sung-Won (우석대학교 토목환경공학과)
Joh, Chang-Bin (한국건설기술연구원 인프라연구실)
Choi, Kwang-Ho (남서울대학교 건축공학과)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.20, no.1, 2016 , pp. 64-71 More about this Journal
Abstract
In this paper, when the composite beam is made with UHPC deck and steel girder, the steel girder takes the form of the inverted-T shape without top flange because of high strength and stiffness of UHPC deck. There is no evaluation by experiment and analysis about the shear connector behavior on the web of steel girder and flexural behavior of inverted-T shape composite beam. By this reason, this study compares between experiment and analysis by using tension softening model of UHPC on the basis of flexural test results of 16 members considering compressive strength of UHPC, spacing of stud and thickness of deck as variables. The results of tensile strength of UHPC by inverse analysis were 6.57 MPa(in case of 120 MPa) and 9.57 MPa(in case of 150 MPa). In case of the test members with small stud spacing, the results of analysis and test were close clearly, and the test members with thick deck and low UHPC compressive strength also similar, but effects were small. As it compared between analysis and experiment totally, the results of analysis and experiment agree well. So the tension softening model of UHPC is reasonably reflected on the real behavior of composite beam of UHPC.
Keywords
Composite beam; Inverted-T shape; Shear connector; Tension softening; UHPC;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Association Francaise du Genil Civil (AFGC) (2002), Betons Fibres a Ultra-Hautes Performances, Association Francaise du Genil Civil, SETRA, France, 24-56.
2 John, H., and George, S. (2010), The Implementation of Full Depth UHPC Waffle Bridge Deck Panels, Federal Highway Administration Highways for Life Technology Partnerships Program, New York, 9-12.
3 Kang, S.T., and Ryu, G.S. (2011), The Effect of Steel-Fiber Contents on the Compressive Stress-Strain Relation of Ultra High Performance Cementitious Composites (UHPCC), Journal of Korea Concrete Institute, 23(1), 67-75 (in Korean).   DOI
4 Tue, N.V., Schneider, H., Simsch, G., and Schmidt, D. (2004), Bearing Capacity of Stub Columns Made of NSC, HSC and UHPC Confined by a Steel Tube, Proceedings of International Symposium on High Performance Concrete ; Ultra High Performance Concrete, Kassel, Germany, 339-350.
5 Yoo, S.W., Ahn, Y., Cha, Y., and Joh, C. (2014), "Experiment of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Steel Girder," Journal of Korea Concrete Institute, 26(6), 761-769 (in Korean).   DOI
6 Yoo, S.W., and Suh, J. (2015), A Study on the Experiment of Flexural Behavior of Composite Beam with Steel Fiber Reinforced UHPC and Inverted-T Steel Considering Compressive Strength Level, Journal of Korea Concrete Institute, 27(6), 677-685 (in Korean).   DOI
7 Yoo, S.W., Yang, I., and Jung, S. (2015), Analysis of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Shaped Steel with Tension Softening Behavior, Journal of Korea Concrete Institute, 27(2), 185-193 (in Korean).   DOI