Browse > Article
http://dx.doi.org/10.4283/JKMS.2012.22.1.023

Method of AC Loss Under a Condition of Sinusoidal Flux Density Using Digital Feedback  

Jang, Pyung-Woo (College of Science and Engineering, Cheongju University)
Abstract
New digital feedback algorithm was developed to measure iron loss of soft magnetic materials under a condition of sinusoidal flux waveform. $V_{in}$(B) curve was used instead of H(B) curve to decide next input waveform in the feedback module so that adjusting phases of current waveform, flux waveform, and input waveform could be removed. The effectiveness of the developed algorithm was verified when iron loss of ferrite cores was measured under frequencies of 1 and 10 kHz.
Keywords
soft magnetic cores; AC loss; digital feedback; V-B curves; sinusoidal flux density;
Citations & Related Records
연도 인용수 순위
  • Reference
1 한국산업규격, 교류자기특성시험방법, KS C 2118 (1996).
2 G. Bertotti, E. Ferrara, F. Fiorillo, and M. Pasquale, J. Appl. Phys. 73, 5375 (1993).   DOI   ScienceOn
3 Yanbin Zhang, Yi Long, Qingchang Qu, Rongchang Ye, and Yong Chang, J. Magn. Magn. Mater. 312, 443 (2007).   DOI   ScienceOn
4 Stan Zurek, Philip Marketos, Turgut Meydan, and Anthony J. Moses, IEEE Trans. Magn. 41, 4242 (2005).   DOI   ScienceOn
5 음영환, 고창섭, 홍선기, 신판석, 전기학회논문지56, 869 (2007).
6 Kazunori Matsubra, Norio Takahashi, Koji Fujiwara, Takahoshi Nakata, Masanori Nakano, and Hitoshi Aoki, IEEE Trans. Magn. 31, 3400 (1995).   DOI   ScienceOn