Experimental Study of Hybrid Super Coating (HSC) and Cast Reinforcement for Masonry Wall
![]() |
Lee, Ga Yoon
(Deep Learning Architecture Research Center, Department of Architectural Engineering, Sejong University)
Moon, A hea (Deep Learning Architecture Research Center, Department of Architectural Engineering, Sejong University) Lee, Seung Jun (Atom Engineering) Kim, Jae Hyun (Atom Engineering) Lee, Kihak (Deep Learning Architecture Research Center, Department of Architectural Engineering, Sejong University) |
1 | Kim HC, Kim KJ, Park JH, Hong WK. Experimental Study on the Material Properties of Unreinforced Masonry Considering Earthquake Load. Journal of the Earq uake Engineering Society of Korea. 2001;5(2):93-101. |
2 | Korean Standards Association. KS L 510 5: Testing Method for Compressive Strength of Hydraulic Cement Mortars. Korean Standards Association. c2017. |
3 | Statistics KOREA Government Official Work Conference[Internet]. 2020.03 [cited 2007 Jan 8]; Available from: http://www.index.go.kr/potal/main/EachDtlPageDetail.do?idx_cd=1226 |
4 | Chang KK, Seo DW. Present State and Necessity of Seismic Design for Low-rise Masonry Buildings in Korea. Journal of the Architectural Institute of Korea. 2011;55(5):45-50. |
5 | Yu E. Seismic Performance and Retrofit of Masonry-infilled Frames. Magazine of the Korea Concrete Institute. 2015;27(6):41-45. DOI |
6 | Pavan GS, Nanjunda Rao KS. Behavior of brick-mortar interfaces in FRP-strengthened masonry assemblages under normal loading and shear loading. Journal of Materials in Civil Engineering. 2016;28(2):04015120. DOI |
7 | Messali F, Metelli G, Plizzari G. Experimental results on the retrofitting of hollow brick masonry walls with reinforced high performance mortar coatings. Construction and Building Materials. 2017;141:619-630. DOI |
8 | Valluzzi MR, Tinazzi D, Modena C. Shear behavior of masonry panels strengthened by FRP laminates. Construction and Building Materials. 2002;16(7):409-416. DOI |
9 | Gams M, Tomazevic M, Berset T. Seismic strengthening of brick masonry by composite coatings: An experimental study. Bulletin of Earthquake Engineering. 2017;15.10:4269-4298. DOI |
10 | ElGawady MA, Lestuzzi P, Badoux M. Retrofitting of masonry walls using shotcrete. In: 2006 NZSEE Conference, Paper. c2006. |
11 | Tomazevic M. Earthquake-resistant design of masonry buildings (Vol. 1). World Scientific. c1999. |
12 | Vega C, Torres N. External strengthening of unreinforced masonry walls with polymers reinforced with carbon fiber. Ingenieria e Investigacion. 2018;38(3):15-23. DOI |
13 | Lee JH. Seismic Capacity and Seismic Retrofitting of Low Rise Buildings - Unreinforced Masonry, Brick-Infilled RC Frame and Steel Slit Damper Retrofitted RC Frame. Ph.D. Thesis, University of Kwangwoon. c2005 |
14 | Yu E, Kim MJ, Lee SH, Kim CM. Relation between Shear Strength of Masonry infills and Seismic Performance of Masonry-infilled Frames. Journal of the Earthquake Engineering Society of Korea. 2015;19(4):173-181. DOI |
15 | Yu HR, Kwon KH. A study on mechanical characteristics of masonry structure constructed by clay brick with lime mortar. Journal of the Korea Institute for Structural Maintenance and Inspection. 2011;15(4):87-98. DOI |
16 | ASTM International. ASTM E518/ E518M-10 Standard Test Methods for Flexural Bond Strength of Masonry. ASTM International, West Conshohocken, PA. c2010. |
17 | Korean Standards Association. KS F 4004. Concrete bricks. Korea Standard Association. c2013. |
18 | Korean Standards Association. KS L 5220. Dry ready mixed cement mortar. Korea Standard Association. c2018. |
19 | ASTM International. ASTM C 1314-12 Standard Test Method for Compressive Strength of Masonry Prisms. ASTM International, West Conshohocken, PA. c2012. |
20 | BS EN 1052-3 Methods of test for masonry-Part 3: Determination of initial shear strength. c2002. |
21 | Yi WH, Lee JH, Oh SH, Yang WJ, Kang DE. A study on evaluation of shear capacity of unreinforced masonry wall. Journal of Architectural Institute of Korea. 2005;21(10):3-10. |
22 | ASTM International. ASTM E 519/E 519M-10 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages. ASTM International, West Conshohocken, PA. c2010. |
23 | Park BT, Kwon KH. Seismic Performance Evaluation of Masonry Infilled Wall With Non-seismic Detail. Journal of the Korean Society of Safety. 2017;32(1):66-74. DOI |
24 | Han SS, Kang THK. A Study on Seismic Performance of Masonry-infilled Reinforced Concrete Frames Retrofitted with High-performance Materials. Journal of the Korea Concrete Institute. 2019;31(5):449-458. DOI |
25 | Korea Infrastructure Safety Corporation. Guidelines for Evaluating Seismic Performance of Existing Building. 2019:96-98 |
![]() |