In-structure Response Evaluation of Shear Wall Structure via Shaking Table Tests |
Jung, Jae-Wook
(Smart Structural Safety and Prognosis Research Division, Korea Atomic Energy Research Institute)
Ha, Jeong-Gon (Smart Structural Safety and Prognosis Research Division, Korea Atomic Energy Research Institute) Hahm, Daegi (Smart Structural Safety and Prognosis Research Division, Korea Atomic Energy Research Institute) Kim, Min Kyu (Smart Structural Safety and Prognosis Research Division, Korea Atomic Energy Research Institute) |
1 | Choi IK. Review and proposal for seismic safety assessment of nuclear power plants against beyond design basis earthquake. Transactions of the Korean Society of Pressure Vessels and Piping. 2017;13.1:1-15. |
2 | Jeon J, Ju BS, Son H. Seismic fragility analysis of curved bridge under high frequency earthquakes. Journal of the Society of Disaster Information. 2020;16(4):806-812. DOI |
3 | Son HY, Jung WY, Jeon BG, Ju BS. Seismic fragility analysis of electrical cabinet at anchor system. Korea Society for Advanced Composite Structures. 2019;10.6:84-90. DOI |
4 | U.S. Nuclear Regulatory Commission. Regulatory Guide 1.60: Design Response Spectra for Seismic Design of Nuclear Plants. c1973. |
5 | Park HG, Yang HK. Evaluation of seismic performance of nuclear power plant walls under beyond design basis earthquake with high-frequency contents. Korea Concrete Institute. 2020 May;32(3):19-25. DOI |
6 | Electric Power Research Institute. Advanced Nuclear Technology: High-Frequency Seismic Loading Evaluation for Standard Nuclear Power Plants (EPRI TR-3002009429). c2017. |
7 | Eem SH, Choi IK. Seismic response analysis of nuclear power plant structures and equipment due to the Pohang earthquake. EESK J. Earthquake Eng. 2018;22(3):113-119. |
8 | Choi IK, Kim JH, Park JH, Kim MK, Jeon JH. Seismic fragility reevaluation of SSCs in NPP with site-specific response spectrum. In Transactions of the Korean Nuclear Society Spring Meeting. c2017. |
9 | Kanee ART, Kani IMZ, Noorzad A. Elastic floor response spectra of nonlinear frame structures subjected to forward-directivity pulses of near-fault records. Earthquakes and Structures. 2013;5(1):49-65. DOI |
10 | Jung JW, Jang HW, Kim JH, Hong JW. Effect of second hardening on floor response spectrum of a base-isolated nuclear power plant. Nuclear Engineering and Design. 2017;322:138-147. DOI |
11 | Suarez LE, Singh MP. Floor response spectra with structure-equipment interaction effects by a mode synthesis approach. Earthquake engineering & structural dynamics, 1987;15(2):141-158. DOI |
12 | Kim DY, Kwon TH. Nonlinear dynamic analysis of RC shear walls subject to in-plane shear. Korea Concrete Institute. 2019 Mar;31(3):285-291. DOI |