1 |
KCI 2012. Building Code for Structural Concrete and Commentary. Korea Concrete Institute. c2012.
|
2 |
ACI 318-14. Building Code Requirements for structural concrete and Commentary. American Concrete Institute. c2014.
|
3 |
ACI 315-99. Details and Detailing of Concrete Reinforcement. American Concrete Institute. c1999, 44 p.
|
4 |
Lynn AC, Moehle JP, Mahin SA, Holmes WT. Seismic evaluation of existing reinforced concrete building columns. Earthquake Spectra. 1996;12(4):715-739.
DOI
|
5 |
Melek M, Wallace JW. Cyclic behavior of columns with short lap splices. ACI Structural Journal. 2004;101(6):802-811.
|
6 |
Aboutaha RS, Engelhardt, MD, Jirsa JO, Kreger ME. Experimental investigation of seismic repair of lap splice failures in damaged concrete columns. ACI Structural Journal. 1999;96(2):297-306.
|
7 |
Haroun MA, Elsanadedy HM. Fiber-reinforced plastic jackets for ductility enhancement of reinforced concrete bridge columns with poor lap-splice detailing. Journal of Bridge Engineering. 2005;10(6):749-757.
DOI
|
8 |
Harries KA, Ricles JM, Pessiki S, Sause R. Seismic retrofit of lap splices in nonductile square columns using carbon fiber-reinforced jackets. ACI Structural Journal. 2006;103(6):874-884.
|
9 |
ElGawady M, Endeshaw M, McLean D, Sack R. Retrofitting of rectangular columns with deficient lap splices. Journal of Composites for Construction. 2010;14(1):22-35.
DOI
|
10 |
Boyes A, Bull DK, Pampanin S. Seismic performance of concrete columns with inadequate transverse reinforcement. 2008:1-12.
|
11 |
Harajli M. Seismic behavior of RC columns with bond-critical regions: Criteria for bond strengthening using external FRP jackets. Journal of Composites for Construction. 2008;12(1):69-79.
DOI
|
12 |
Bournas DA, Triantafillou TC, Zygouris K, Stavropoulos F. Textilereinforced mortar versus FRP jacketing in seismic retrofitting of RC columns with continuous or lap-spliced deformed bars. Journal of Composites for Construction. 2009;13(5):360-371.
DOI
|
13 |
Kim CG, Eom TS, Park HG, Kim TW. Seismic performance of RC columns with lap splices at plastic hinge region. Journal of the Architectural Institute of Korea. 2015;31(12):23-33.
|
14 |
CSA. Design of Concrete Structure. Canadian Standard Association. c2004.
|
15 |
Eurocode 2. Design of Concrete Structures: Part 1-1: General Rules and Rules for Buildings. British Standards Institute. c2004.
|
16 |
ACI 374.1-05. Acceptance criteria for moment frames based on structural testing and commentary. American Concrete Institute. c2005. 9 p.
|
17 |
Orangun CO, Jirsa JO, Breen JE. A reevaulation of test data on development length and splices. ACI Journal Proceedings. 1977;74(3):114-122.
|