Browse > Article
http://dx.doi.org/10.5000/EESK.2015.19.4.195

Effects of Tie Details on Seismic Performance of RC Columns Subjected to Low Compression Loads  

Kim, Chul Goo (Architecture, Seoul National University)
Park, Hong Gun (Architecture, Seoul National University)
Eom, Tae Sung (Architectural Engineering, Dankook University)
Kim, Tae Wan (Architectural Engineering, Kangwon National University)
Publication Information
Journal of the Earthquake Engineering Society of Korea / v.19, no.4, 2015 , pp. 195-205 More about this Journal
Abstract
Various non-seismic tie details are frequently used for one- and two-story small buildings because the seismic demand on their deformation capacities is not relatively significant. To evaluate the effects of the non-seismic tie details on the seismic performance of reinforced concrete columns, six square columns with a cross section of $400{\times}400mm$ and six rectangular columns with a cross section of $250{\times}640mm$ were tested. The anchorage details at both ends and spacing of tie hoops, along with the cross-sectional shape and the magnitude of axial load, were considered as the primary test parameters. Test results showed that square columns had higher stiffness and lower lateral deformation rather than rectangular columns. Both lap spliced tie and U-shaped tie provided comparable or improved seismic performance to $90^{\circ}$ hook tie in terms of maximum strength, ductility, and energy dissipation. The predicted curves with modeling parameters in ASCE41-13 were conservative for test results of lap spliced tie and U-shaped tie specimens since plastic behavior after flexural yielding could not be considered. For economical design, ASCE41-13 should be revised with various test results of tie details.
Keywords
Tie detail; Rectangular column; Seismic performance; Lap spliced tie; U-shaped tie;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Kwon KH, Park SH, Choi OC, Oh SH, Yoon MH, Moon TS. An experimental study on hysteretic behavior of full-size reinforced concrete exterior beam-column joints. Architecutral Institute of Korea. 2003;19(6):19-26.
2 Pampanin S, Calvi G, Moratti M. Seismic behavior of RC beamcolumn joints designed for gravity only. Proceedings of the 12th European conference on Earthquake Engineering. c2002.
3 Calvi G, Magenes G, Pampanin S. Experimental test on a three storey reinforced concrete frame designed for gravity only. Proceedings of the 12th European conference on Earthquake Engineering. c2002.
4 Lam S, Wu B, Wong Y, Wang Z, Liu Z, Li C. Drift capacity of rectangular reinforced concrete columns with low lateral confinement and high-axial load. Journal of Structural Engineering. 2003;129(6):733-42.   DOI   ScienceOn
5 Lukkunaprasit P, Sittipunt C. Ductility enhancement of moderately confined concrete tied columns with hook-clips. ACI structural Journal. 2003;100(4):422-9.
6 RazviI SR, Saatcioglu M. Confinement of reinforced concrete columns with welded wire fabric. ACI Structural Journal. 1989;86(5):615-23.
7 KBC 2009. Korean building code and commentary. Seoul, Korea: Architectural Institute of Korea; c2009. 1039 p.
8 ACI 374.1-05. Acceptance criteria for moment frames based on structural testing and commentary. Michigan, USA: American Concrete Institute; c2005. 9 p.
9 ASCE/SEI 41-13. Seismic evaluation and retrofit of existing buildings. Virginia, USA: American Society of Civil Engineers,; c2013. 555 p.
10 Park R, Ductility evaluation from laboratory and analytical testing. Proceedings of the 9th World Conference on Earthquake Engineering, Tokyo-Kyoto, Japan; 1988 Aug: 605-16
11 Elwood KJ, Moehle JP. Drift capacity of reinforced concrete columns with light transverse reinforcement. Earthquake Spectra. 2005 Feb;21(1):71-89.   DOI   ScienceOn
12 Elwood KJ, Eberhard MO. Effective stiffness of reinforced concrete columns. ACI Structural Journal. 2009 Jul-Aug;106(4):476-84.
13 Lee YW, Park HG, C hoi DB. An experiment to enhance the deformation capacity of RC exterior joint with the non-seismic details. Architectural Institute of Korea. 2009;25(8):27-34.
14 KSEA. Structural design criteria and commentary for one and two story small buildings. Seoul, Korea: Korean Structural Engineers Association; c2012. Chapter 3, Concrete structure; p. 39-69.
15 Sezen H, Moehle JP. Seismic tests of concrete columns with light transverse reinforcement. ACI structural journal. 2006 Nov-Dec;103(6):842-9.
16 Wibowo A. Drift Capacity of Lightly Reinforced Soft Storey Structures. Rekayasa Sipil. 2013;7(2):166-77.