The Emergency Diesel Generator (EDG) is a very important equipment for the safety of a Nuclear Power Plant (NPP). In this study, the operating vibration of three kinds of EDG systems was measured. The target EDG systems are Yonggwang 5 unit and Ulchin 2 and 3 units. The Yonggwang 5 and Ulchin 3 unit EDG systems are the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of these measurements is for a verification of the vibration isolation effect depending on the foundation system. As a result, It can be said that the spring and viscous damper system of the EDG performed better for the vibration isolation than that of anchor bolt type.
Keywords
Emergency Diesel Generator (EDG); Nuclear Power Plant (NPP); foundation system; anchor bolt; coil spring-viscous damper; vibration isolation effect;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kumar, J. and Reddy, C.O., 'Dynamic Response of Footing and Machine with Spring Mounting Base,' Geotechnical and Geological Engineering, 2006, 24: 15-27   DOI
2 Macinate, J.A., Seismic Mountings for Vibration Isolation, John Wiley & Sons, 1984
3 이종림, 장승필, 진동저감시스템을 갖춘 회전기계기초의 지진하중에 대한 동적거동, 대한토목학회논문집, 제17권 제I-2호, 1997, pp. 313-323
4 장승필, 임성순, 조대연, 이종림, 진동 저감요소를 갖춘 회전기계기초의 동적해석, 한국강구조학회논문집, 제3권, 제3호, 1991, pp. 175-188
5 Lin, W. and Novak, M., 'Dynamic Behavior of TurbineGenerator-Foundation Systems,' Earthquake Engineering and Structural Dynamics, Vol. 24, 1995, pp. 339-360   DOI   ScienceOn