Abstract
This study is to evaluate the tool life of portable beveler which have various cooling system. It was compared with 3 different bevelers which has each other cooling system. Beveler A has no cooling system, beveler B has the cooling system for only inside of body, and beveler C has the cooling system for both the cutter and inside of body. The temperature of beveler A cutter surface had been continuously increasing as processing, but the rising tendency of temperature of beveler B cutter surface has slightly changed. In case of beveler C, the temperature is maintained. The tool life of beveler C is about 105m which is around 400% of beveler A(25m), and around 130% of beveler B(80m).
Keywords
Beveler; Tool Life; Flank Wear Land;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 In, C. B. and Chun, S. S., 1993, "Wear Behavior of TiN Coatings Deposited by Plasma Assisted Chemical Vapor Deposition," MRSK, Vol. 3, No. 5, pp. 451-458   과학기술학회마을
2 Chun, S. S., 1981, "New Development of Long-Life Cutting Tool Materials," KAIST Press, Republic of Korea, pp. 1-54
3 Kim, J. H. and Kim, H. S., 1994, "A Study on Optimal Design of Face Milling Cutter Geometry(II) -With Respect to Tool Life and Surface Roughness," KSME, Vol. 18, No. 9, pp. 2225-2233   과학기술학회마을
4 Kim, S. W., Ahn, C. S., and Lee, D. W., 2000, "Evaluation of Machinability by Cutting Environments in High-Speed Machining of Difficult-to-cut Materials," KSMTE, Vol. 9, No. 6, pp. 158-163   과학기술학회마을