Browse > Article
http://dx.doi.org/10.7843/kgs.2012.28.10.17

A Study on the Lattice Girder by Increasing Contacting Area between Spider and Rod  

Nam, Joong-Woo (Dept. of Civil and Environmental Engrg., Hanyang Univ.)
Kim, Jin-Kyo (Dasan Consultants Co., Ltd.)
Cho, Yong-Gyo (Bolim Co., Ltd.)
Chun, Byung-Sik (Dept. of Civil and Environmental Engrg., Hanyang Univ.)
Publication Information
Journal of the Korean Geotechnical Society / v.28, no.10, 2012 , pp. 17-25 More about this Journal
Abstract
Shotcrete, rockbolt, and steel rib are installed to support ground after tunnel was excavated. These are important supports for NATM applied tunnels. Recently, lattice girder is increasingly used because it is easily installed. In this study, we developed a new lattice girder by increasing contacting area between spider and rod. To verify the effect of the new lattice girder, the 3-point and 4-point flexural strength tests were carried out for LG-$50{\times}20{\times}30$, LG-$70{\times}20{\times}30$, LG-$95{\times}22{\times}32$. As a result, in case of contacting area, strength of new SGS lattice girder is 17.95% higher than that of original lattice girder. In case of weakness point, strength of new SGS lattice girder is 19.37% higher than that of original lattice girder.
Keywords
3-point flexural strength test; 4-point flexural strength test; Lattice girder; New spider; Support; Tunnel;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김동규, 최윤호, 김동률 (2007), "레티스거더 성능평가를 위한 실내시험기법의 평가", Korean Geotechnical Society conference, pp.1113-1120.
2 Baumann, T. and Betzle M. (1984), "Investigation of the performance of lattice girders in tunnelling", Rock mechanics and Rock Engineering, Vol.17, pp.67-81.   DOI   ScienceOn
3 Braun, W. M. (1983) "Lattice Girders Offer Economy and Performance for Tunnel Support", Tunnels & Tunnelling, Vol.15, No.5, pp.19-22.
4 Kim, D. G. and Bae, G. J. (2008a), "Development of a laboratory testing method for evaluating the loading capability of lattice girder", Journal of Korean Tunnelling Association, Vol.10, No.4, pp.371-382
5 Kim, D. G., Lee, S. H., and Choi, Y. N. (2008b), "Evaluatiion of Loading Capacity of Laattice Girder according to Laboratory Testing Method", Korean Geo-Environmental Conference, pp.399-406.
6 K.I.C.T. (1996), "Application of Lattice Girders in Tunnelling", 천원공업(주), pp.1-99.
7 KS D 3504, "Deformed Steel Bar", pp.3-5.
8 Moon, H. D. (1997), "Mechanical Characteristics and Applicability of a Lattice Girder for a Support in Tunnelling", Ph.. D. degree thesis, Kyounghee University, pp.35-52.
9 Moon, H. D. (1999), "Evaluation on the Applicability of a Lattice Girder for a Support System in Tunnelling", Journal of Korean Society for Rock Mechanics, Vol.9, pp.204-213.
10 Weber, J. (1983) "Erfahrungen mit Druckluftvortrieben in Spritzbetonbauweise beim M/inchner U-Bahn-Bau", Vortrag auf der STUVA-Tagung Tunnel 1983.
11 Yang, H. S., Jeong, H. S., and Kim, W. B. (2005), "Numerical Analysis for the Structural Behavior of Lattice Girder", Journal of Korean Society for Rock Mechanics, Vol.15, No.4, pp.243-249.