Domestic usage of high strength steel for pile has been limited to steel with yield strength (YS) of 490 MPa. However, design and construction cases abroad show beneficial usage of steel pipe with YS ranging in 500~700 MPa. In this study, YS 590 MPa steel pipe has been tested for driven pile foundation in Songdo area. Pile dynamic analysis (PDA) was carried out for 18 piles of which 16 piles have been reviewed for comparison of the PDA test results with those of GRLWeap analysis using SPT N value. Back analysis of PDA analysis was also carried out to narrow the deviation of standard SPT N value used in GRLWeap analysis. A regression equation is suggested for the shaft and toe resistance according to SPT N values for future GRLWeap analysis that can be used in the designing stage at Songdo area.
Keywords
Driveability; Dynamic load test; GRLWeap; High strength steel pipe pile;
Citations & Related Records
연도 인용수 순위
  • Reference
1 나승민, 유한규, 이장덕, 조천환 (2009), "송도지역 재하시험결과 분석을 통한 고강도 강관말뚝의 적용성 분석", 2009 한국지반공학회 기초기술위원회 워크샵, pp.80-88.
2 이명환 (2004), "국내 말뚝 기초의 현황 및 향후 전망", 2004 한국지반공학회 기초기술 위원회 워크샵, pp.165-177.
3 이우진 (1998), "Weap을 이용한 강관말뚝의 항타시공성의 합리 적 해석", 한국강구조학회지, 제10권 1호, pp.123-136.
4 포항종합제철 (1997), "고강도강관 말뚝의 적용을 위한 연구", PSC, pp.172.
5 Finnish National Road Administration(2004), Steel Pipe Piles.