Browse > Article
http://dx.doi.org/10.7843/kgs.2008.24.5.37

Bearing Capacity of SDA Augered Piles in Various Grounds Depending on Water-Cement Ratio of Cement Milk  

Hong, Won-Pyo (Dept. of Civil Eng., Chung-Ang Univ.)
Lee, Jae-Ho (Dept. of Civil Eng., Chung-Ang Univ.)
Chai, Soo-Geun (Dept. of Civil Eng., Chung-Ang Univ.)
Publication Information
Journal of the Korean Geotechnical Society / v.24, no.5, 2008 , pp. 37-54 More about this Journal
Abstract
The standard construction manual of the SDA (Separated Doughnut Auger) piling method was proposed so that the resisting capacity of the augered piles could work effectively. 438 dynamic pile load tests were performed on 379 test piles, which were installed at 36 sites in Korea by the SDA piling method with application of various water-cement ratio of cement milks. The dynamic pile load test results showed that the bearing capacity of the SDA augered piles depended on the water-cement ratio of cement milks. And couple of the formulas were presented according to water-cement ratio and various grounds to estimate quantitatively both the unit end bearing and the unit frictional capacity of the SDA augered piles. It was also considered that the water-cement ratio of cement milks exerts an influence on the bearing capacity of the SDA augered piles. The presented formulas were compared with the existing formulas, which were presented by several standard design codes to design the augered piles.
Keywords
Augered pile; Cement milk; End bearing capacity; EOID; Frictional capacity; N-value; Pile load test; Restrike; Water-cement ratio;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 김정수 (2003), 화강풍화대 지반에 매입된 SIP말뚝의 지지력 평 가에 관한 연구, 박사학위논문, 한양대학교, pp.161-165
2 대한토목학회 (2001), 도로교설계기준 해설, pp.207-313
3 한국지반공학회 (2003), 구조물기초설계기준 해설, pp.286-292
4 GRL Associates Inc. (1996), Case Pile Wave Analysis Program Manual
5 津田和義(2003), 旣製コンクリート杭- 基礎構造設計manual - 土木編, (社)コンクリートバイル建設技術協會, 附錄5-1-5-5
6 채수근 (2000a), "Q&A 매입말뚝 시공법", 한국지반공학회지, Vol.16, No.7 pp.63-68
7 서울특별시 (1996), 지반조사 편람, pp.22-24
8 홍원표, 한중근, 채수근 (2002), "SDA매입말뚝의 마찰지지력", 대한토목학회 학술발표논문, pp.5-8.
9 채수근 (1997), "SDA매입말뚝 신공법 연구 및 적용성 검토서", pp.1-110
10 이 송, 박준홍, 박중배, 김태훈 (2002), "국내 SIP 말뚝의 지지력 특성에 관한 연구", 한국지반공학회논문집, 제18권 4호, pp.319-327
11 채수근 (2000b), "SDA매입말뚝 신공법 -한국고속철도 3공구 평택고가 적용 사례 중심으로", 대한토목학회지, 제48권 제9호 pp. 54-62
12 홍원표, 채수근 (2007b), "지반종류별 SDA매입말뚝의 마찰지지력 산정", 대한토목학회논문집, 대한토목학회,제27권, 제4C호, pp.279-292
13 채수근 (2002), SDA매입말뚝의 연직지지력 산정,석사학위논문, 중앙대학교, pp.1-121
14 두성건설 (1987), SIP기초공법, pp.1-68
15 이명환 외 (1992), "실측에 의한 표준관입시험 함마의 낙하속도 분석", 한국지반공학회지, 제8권 1호, pp.59-66
16 COPITA (2006), (社)コンクリートバイル建設技術協會, Concrete Pile Installation Technology Association, 2006. 4. NO.39, pp.21-76
17 (社)コンクリートバイル建設技術協會(1994), "埋入み工法 施工便覽", pp.13-182
18 이원제 (2000), 광섬유센서를 이용한 매입말뚝의 하중전이 측정 및 지지력 특성 연구, 박사학위논문, 고려대학교, pp.114-121
19 Hong, Won-Pyo and Chai, Soo-Geun (2003), "Skin Friction Capacity of Separated Doughnut Auger (SDA) Pile", The Proceeding of the 13th International Offshore and Polar Engineering Conference (ISOPE-2003), Honolulu, Hawaii, U.S.A, pp.740-745
20 대한건축학회 (2005), 건축기초구조설계기준, pp.172-184
21 채수근 (2004), 기초공사실무, (재)건설산업교육원, pp. 66-70
22 채수근 (2007), 시멘트밀크 배합비에 따른 다양한 지반 내 SDA 매입말뚝의 연직지지력, 박사학위논문, 중앙대학교, pp.1-262
23 서영화, 조성한, 최도웅, 한병권 (2003), "말뚝 매입공법의 최적설계기준 연구", 대한토목학회지, 제51권 제7호 pp.8-16
24 대한주택공사 (1997), 표준시방서(건축) 30535 말뚝선굴착공법, pp.1-9.
25 Pile Dynamics Inc. (1995), PDI User Manual
26 채수근 (2005), 말뚝기초실무, (재)전문건설공제조합 기술교육원, pp.22-27
27 한국도로공사 (2006), "한국도로공사의 SIP공법 소개", 2006 현장기술자를 위한 기초기술 워크샵, 한국지반공학회, pp.103-124
28 Hong, Won-Pyo and Chai, Soo-Geun (2005), "Bearing Capacity Characteristics of Separated Doughnut Auger (SDA) Pile in Clay and Silty Soil", The Proceeding of the 15th International Offshore and Polar Engineering Conference (ISOPE-2005), Seoul, Korea, pp.548-554
29 홍원표, 채수근 (2007a), "지지지반의 종류별 SDA매입말뚝의 선단지지력 산정", 한국지반 공학회논문집, 한국지반공학회, 제23권, 5호, pp.111-129   과학기술학회마을
30 임해식,박용부,박종배,김정수,한경렬,김도형(2001),SIP공법의 품질개선방안과 지지력 산정법 제안에 관한 연구, 대한주택공사 주택연구소, pp.68-79