A geothermal heat pump system is a preferable alternative energy system in Korea because it uses the heat energy of the earth, which is environmentally friendly and inexhaustible. In order to characterize the thermal conductivity and viscosity of grout materials used for backfilling ground heat exchangers, nine bentonite grouts, one marine clay from Boryung, and cement grouts adapted in the United State have been considered in this study. The bentonite grouts indicate that the thermal conductivity and viscosity increase with the content of bentonite or filler (silica sand). In addition, material segregation can be observed when the viscosity of grout is relatively low. The marine clay turns out to be unsuitable for backfilling the ground heat exchanger due to its insufficient swelling potential. The saturated cement grouts appear to possess much higher thermal conductivity than the saturated bentonite grouts, and the reduction of thermal conductivity in the cement grouts after drying specimens is less than that in the case of the bentonite grouts. Maintaining the moisture content of grouts is a crucial factor in enhancing the efficiency of ground heat exchangers.
Keywords
Bentonite; Geothermal grouts; Ground heat exchanger; Thermal conductivity; Viscosity;
Citations & Related Records
연도 인용수 순위
  • Reference
1 조정식 (2006), "지중 열교환기 전열성능 향상을 위한 뒤채움재 조성에 관한 연구.", 산업자원부, 최종보고서 2004-N-GE08-P-01
2 Allan, M. L. and Philippacopoulos, A. (1999). "Properties and performance of cement-based grouts for geothermal heat pump application.", U.S. Department of Energy, Washington D.C.
3 Philippacopoulos, A. and Berndt, M. L. (2001). "Influence of debonding in ground heat exchanger used with geotherma heat pumps.", Geothermics, vol.30, pp.527-545   DOI   ScienceOn
4 Paul, N. D. and Remund, C. P. (1997). "Physical, thermal and hydraulic properties of bentonite-based grouts.", Electric Power Research Institue, Final Report No.TR109160, ERI Project RP38 81-1
5 Allan, M. L. (2000). "Materials characterization of superplasticized cement-sand grout.", Cement and Concrete Research, vol.30, pp.937-942   DOI   ScienceOn