Shear Strength of Hairpin Reinforced Cast-In-Place Anchors by Static and Seismic Qualification Tests  

Kim, Dong Hyun (Dept. of Civil Engineering, Pusan National University)
Park, Yong Myung (Dept. of Civil Engineering, Pusan National University)
Kim, Tae Hyung (Dept. of Civil Engineering, Pusan National University)
Jo, Sung Hoon (Dept. of Civil Engineering, Pusan National University)
Kang, Choong Hyun (School of Architectural and Civil Engineering, Kyungpook National University)
Publication Information
Journal of Korean Society of Steel Construction / v.27, no.3, 2015 , pp. 333-345 More about this Journal
Abstract
This study evaluated the static and dynamic shear strength of cast-in-place anchors reinforced with hairpin bars in uncracked and cracked concrete. The anchors 30mm in diameter reinforced with D10 hairpin bar were designed with an edge distance of 150mm and an embedment depth of 240mm. The cracked specimens consisted of the orthogonal and parallel cracks to the direction of shear loads, respectively. The dynamic strength was evaluated using seismic qualification tests based on the ACI 355.2 standard. The shear strength of the hairpin reinforced anchor was hardly correlated to the concrete cracks and the dynamic strength was similar to its static shear strength. Finally, a consideration on the design strength of hairpin reinforced anchors was presented.
Keywords
Hairpin-reinforced; Cast-in-place anchor; Shear strength; Seismic qualification test; Uncracked and cracked concrete;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 ACI Committee 318-02 (2002) Building Code Requirements for Structural Concrete and Commentary, ACI 318-02, Appendix D: Anchoring to Concrete, American Concrete Institute.
2 ACI Committee 318-11 (2011) Building Code Requirements for Structural Concrete and Commentary, Appendix D: Anchoring to Concrete, American Concrete Institute.
3 ACI Committee 318-08 (2008) Building Code Requirements for Structural Concrete and Commentary, Appendix D: Anchoring to concrete, American Concrete Institute.
4 Klingner, R.E., Mendonca, J.A., and Malik, J.B.(1982) Effect of Reinforcing Details on the Shear Resistance of Anchor Bolts Under Reversed Cyclic Loading, ACI Journal, Title No. 79-1, pp. 3-12.
5 Lee, N.H., Park, K.R., and Suh, Y.P. (2010) Shear behavior of headed anchors with large diameters and deep embedments, ACI Structural Journal, Vol. 107, No. 4, pp. 146-156.
6 박용명, 강문기, 노진경, 주호중, 강충현(2014) 선설치앵커의 동적 전단하중에 대한 저항강도: 철근보강 앵커, 한국강구조학회논문집, 한국강구조학회, 제26권, 제1호, pp.21-31. (Park, Y.M., Kang, M.K., Roh, J.K., Ju, H.J., and Kang, C.H. (2014) Shear Resistance of CIP Anchors Under Dynamic Loading: Reinforced Anchor, Journal of Korean Society of Steel Construction, KSSC, Vol.26, No.1, pp.21-31 (in Korean).)
7 Eligehausen, R., Mallee, R., and Silva, J.F. (2006) Anchorage in Concrete Construction, Ernst & Sohn, Germany.
8 Gross, J.H., Klingner, R.E., and Graves III, H.L. (2001) Dynamic Anchor Behavior of Single and Double Near-Edge Anchors Loaded in Shear, Connections between Steel and Concrete (Int. Conference organized by University of Stuttgart, Co-sponsored by ACI, fib, IABSE, edited by R. Eligehausen), RILEM Publications S.A.R.L., pp.498-508.
9 CSA N287.2 (1998) Material Requirements for Concrete Containment Structures for CANDU Nuclear Power Plants, Canadian Standards Association, Rexdale, Ontario.
10 ACI 355.2 (2000) Evaluating the Performance of Post-installed Mechanical Anchors in Concrete, Reported by ACI Committee 355.
11 ETAG 001(2013) Guideline for European Technical Approval of Metal Anchors for Use in Concrete, European Organization for Technical Approvals (EOTA).
12 박용명, 김태형, 김동현, 조성훈, 이종한(2015) 지진모의실험에 의한 비균열 및 균열콘크리트에 매입된 비보강 선설치앵커의 전단 저항강도 평가, 한국강구조학회논문집, 한국강구조학회, 제27권, 제3호, pp. 347-357. (Park, Y.M., Kim, T.H., Kim, D.H., Cho, S.H. and Lee, J.H. (2015) Shear Resistance of Unreinforced Cast-In-Place Anchors in Uncracked and Cracked Concrete by Seismic Qualification Tests, Journal of Korean Society of Steel Construction, KSSC. Vol.27, No.3, pp. 347-357.)
13 박용명, 주호중, 김동현, 강문기, 이종한(2015) 균열콘크리트에 매입된 선설치앵커의 정적 전단하중에 대한 저항강도, 한국강구조학회논문집, 한국강구조학회, 제27권, 제1호, pp.97-97. (Park, Y.M., Ju, H.J., Kim, D.H., Kang, M.K., and Lee, J.H. (2015) Static Shear Resistance of Cast-In-Place Anchors in Cracked Concrete, Journal of Korean Society of Steel Construction, KSSC, Vol.27, No.1, pp.87-97 (in Korean).)