Abstract
A T-stub connection with high-strength bolts under tensile force is affected by prying action force and the contact force, among others, between members. If a design equation that does not consider such prying action force and contact force between members is not proposed, the T-stub under tensile force is liable to be fractured under the strength lower than the estimated design strength. To prevent it, many studies have proposed contact force estimation equations between members as well as the prying action force of the T-stub connection with high-strength bolts. However, no design equations based on such research have been proposed in South Korea. Therefore, this study aims to propose an estimation model for more accurate prying action force and contact force, and improve on previously proposed estimation models by implementing the three-dimensional, nonlinear finite element analysis. Throughout the results of three-dimensional, nonlinear finite element analysis, the prediction model proposed in this research for the prying action force and contact force of a T-stub provided much more accurate estimation than that of a existing prediction model previously suggested.
Keywords
prying action force; contact force; design strength; high-strength bolts; T-stub;
Citations & Related Records
연도 인용수 순위
  • Reference
1 양재근, 박재호, 백민창 (2012) 고력볼트로 체결된 T-stub의 지레작용력 및 접촉력예측모델, 2012년도 추계학술발표논문집, 대한건축학회, 제32권, 제2호, pp.465-466. Yang, J.G., Park, J.H., and Back, M.C. (2012) Prediction models for the prying action force and contact force of a T-stub fastened by highstrength bolts, Proceedings of Annual AIK Conference, AIK, pp.465-466.
2 AISC (2010) Steel Construction Manual, 14th Ed., American Institute of Steel Construction, Chicago, II. pp. 9-10 - 9-13.
3 Lemonis, M.E. and Gantes, C.J. (2006) Incremental modeling of T-stub connections, Jounal of Mechanics of Materials and Structures, Vol. 1, No. 7, pp. 1135-1159.   DOI
4 Thornton, W.A. (1985) Prying action: A general treatment, Engineering Journal, AISC, Vol. 22, No. 2, pp.67-75.
5 Astaneh, A. (1985) Procedure for a design and analysis of hanger-type connections, Engineering Journal, AISC, Vol. 22, No. 2, pp.63-66.
6 ABAQUS. (2007) User's manual, I-IV(Version 6.9)
7 Richard, R.M., Hsia, W.K., and Chmielowiec, M. (1988) Derived moment-rotation curves for doubleframing angles, Comput & Struct, Elsevier Science Ltd., 3, pp.485-494.
8 Ballio, G. and Mazzolani, F.M. (1994) Strutture in A cciaio. Hoepli, Milan.
9 Kulak, G.L., Fisher, J.W., and Struik, J.H.A. (2001) Guide to design criteria for bolted and riveted joints, 2nd Ed., American Institute of Steel Construction, New York.
10 Bursi, O. (1990) Behaviour of high strength bolts in bolted beam-to-column connections, Proceedings of Applied Stress Analysis Conference, Nottingham.
11 Hantouche, E.G. (2011) Behavioral characterization of built-up T-stub connections for use in moment resisting frames, Ph.D. Dissertation, University of Cincinnati, Cincinnati, USA.
12 Douty, R.T. and McGuire, W. (1965) High strength bolted moment connections, J. Struct. Div., ASCE, Vol. 91, No. 2, pp.101-128.
13 Agerskov, H. (1976) High strength bolted connections subject to prying. Journal of Structural Engineering Div., ASCE, Vol. 102, No. 1, pp.161-175.
14 Struik, J.H.A. and de Back, J. (1969) Tests on bolted T-stubs with respect to bolted beam-tocolumn connections, Report 6-69-13, Stevin Laboratory, Delft University of Technology, Delft, The Netherlands.
15 Swanson, J.A. (1999) Characterization of the strength, stiffness, and ductility behavior of T-stub connections, Ph.D. Dissertation, Georgia Institute of Technology, Atlanta, USA.
16 Swanson, J.A. (2002) Ultimate strength prying models for bolted T-stub connections, Engineering Journal, AISC, Vol. 39, No. 3, pp.136-147.
17 Jaspart, J.P., Steenhuis, M., and Weinand, K. (1995) The stiffness model of Revised Annex J of Eurocode 3, Proceedings of 3rd International Workshop on Connection in Steel Structures, Trento, pp.28-31.
18 Jaspart, J.P. and Maquoi, R. (1995) Effect of bolt preloading on joint behaviour, Steel Structures, Eurosteel '95, edited by Kounadis, Balkema.
19 Faella, C., Piluso, V., and Rizzano, G. (1996) Some proposals to improve EC3-Annex J Approach for predicting the moment-rotation curve of extended end plate connections, Costruzioni Metalliche, No. 4.
20 Faella, C., Piluso, V., and Rizzano, G. (1998) Experimental analysis of bolted connections: snug versus preloaded bolts, Journal of Structural Engineering, ASCE, Vol. 124, No. 7, pp.765-774.   DOI   ScienceOn