This study focuses on the seismic behavior of 3-, 9-, and 20-story steel moment resisting frame (MRF) structures designed in accordance with the 2000 International Building Code using different Response Modification factors (R factors), i.e., 8, 9, 10, 11, and 12. For a detailed case study, 30 different structures were evaluated for 20 ground motions representing the hazard level, which is equal to a 2% probability in 50 years (2% in 50 years). The results showed that the current R factors provide conservative designs for the 3- and 9-story buildings for the Collapse Prevention performance objective. the 20-story buildings, which were designed without using the minimum requirement of spectral acceleration CS prescribed in IBC 2000, did not satisfy the seismic performance for Collapse Prevention performance.
Keywords
Response modification factor; Earthquake engineering; Seismic performance evaluation; steel moment frame;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Miranda, E. and Bertero, V. V., Evaluation of strength reduction factors for earthquake- resistant design. Earthquake Spectra, EERI, V.10, No.2, 1994, pp. 357-379   DOI   ScienceOn
2 Newmark, N. M. and Hall, W. J., Earthquake Spectra and Design. EERI Monograph Series, EERI, Oakland, CA, 1982
3 Vamvatsikos, D. and Cornell, C. A., Incremental Dynamic Analysis. J. of Earthquake Engr. and Structural Dynamics, Vol.31, No.3, 2002, pp. 491-514   DOI   ScienceOn
4 Prakash, V., Powell, G.H., and Campbell, S, Drain- 2DX, Element description and user guide. Univ. of California, Berkeley, CA, 1993
5 Lee, K. and Foutch, D. A. Performance evaluation of new steel frame buildings for seismic loads. J. of Earthquake Engr. & Str. Dynamics, Vol.31, No.3, 2002, pp. 653-670   DOI   ScienceOn
6 ATC, A critical review of current approaches to earthquake-resistant design. ATC-34, Applied Technology Council, Redwood City, CA, 1995
7 FEMA 355 Seismic Design Criteria for Steel Moment- Frame Structures, Federal Emergency Management Agency, Washington D.C. 2000
8 SEAOC, Recommended lateral force requirements and commentary. Seismology Committee, Structural Engineers Association of California, Sacramento, CA, 1959
9 Ang, A. H-S. and Tang, W.H. Probability Concepts in Engineering Planning and Design Vol.I and II, John Wiley & Sons, New York, 1975
10 Korean Building Code (Structural). 대한건축학회, 2005
11 Foutch, D. A. and Shi, S., Effects of hysteresis types on the seismic effects of buildings. Proceeding, 6th U.S. Nat. Conf. on Earthquake Engr., Seattle, WA, May 31-June 4, 1998, Earthquake Engr. Research Institute, Oakland, CA, 1998
12 ATC, Tentative recommendations for the development of seismic regulations for buildings. ATC 3-06 Report, Applied Technology Council, Redwood City, CA, 1978
13 Venti, M and Engelhardt M.D., Brief report of steel moment conn. test, secimen DBBW (Dog bone - bolted web). SAC Background Document SAC/ BD-99/26, SAC Joint Venture, Richmond, CA, 1997
14 Krawinkler, H. and Al-Ali, A. Seismic demand evaluation for a 4-story steel frame structure damaged in the Northridge Earthquake, The Structural Design of Tall Buildings, Vol. 5, No. 1, March 1996, pp 1-27   DOI
15 International Building Code. International Code Council, Falls Church, VA, 2000
16 Shi, S. and Foutch, D.A., Connection element (type 10) for Drain-2DX. Civil Eng. Report, Univ. of Illinois at Urbana-Champaign, IL, 1997
17 Somerville, P., Smith, N, Puntamurthula, S, and Sun, J., Development of ground motion time histories for phase 2 of the FEMA/SAC steel project. SAC Background Document SAC/BD-97/04, SAC Joint Venture, Richmond, CA, 1997