Experimental Study on the Shear Capacity of Continuous Cap-Type Shear Connector |
Oh, Myoung Ho
(Dept. of Architectural Engineering, Mokpo National Univ.)
Kim, Young Ho (NTAGE) Jeong, Sug Chang (Dept. of Architecture, Bucheon University) Kim, Myeong Han (Dept. of Architectural Engineering, Mokpo National Univ.) |
1 | Chae, H. S., Ryoo, J. Y., Chung, K. S., Moon, Y. M., & Choi, S. M., "Experimental Study on Structural Performance of End-reinforced Steel-beam system(Eco-girder)", Journal of Korean Society of Steel Construction, Vol.22, No.6, pp.533-541, 2010 |
2 | Heo, B. W., Bae, K. W., & Moon, T. S., "Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate", Journal of Korean Society of Steel Construction, Vol.16, No.2, pp.235-245, 2004 |
3 | Park, K. S., Heo, B. W., Kwak, M. G., & Bae, K. W., "Experimental Study of the Flexural Behavior of Encased Composite Beam for Residential Buildings", Journal of the Architectural Institute of Korea Structure and Construction, Vol.24, No.12, pp.91-98, 2008 |
4 | Kim, D. B., Kim, Y. H., Oh, M. H., & Kim, M. H., "Experimental Study on the Flexural Capacity of the Concrete-Filled Composite Beam with Exposed Top Flange", Journal of the Korean Society of Hazard Mitigation, Vol.17, No.4, pp.1-9, 2017 DOI |
5 | Lee, M. H., Oh, M. H., Kim, Y. H., Jeong, S. C., & Kim, M. H., "Experimental Study on the Shear Capacity of Slim AU Composite Beam", Journal of Korean Association for Spatial Structures, Vol.17, No.3, pp.99-105, 2017 DOI |
6 | Kim, S. B., Hwangbo, C., Lee, T. K., Cho, H. S., & Kim, S. S., "The Shear Strength Evaluation of the New Shear Connector by Push-out Test", Journal of the Korean Society of Hazard Mitigation, Vol.14, No.1, pp.1-10, 2014 DOI |
7 | Kim, Y. J., Bae, J. H., Ahn, T. S., & Jang, D. W., "Pushout Test on Welded Angle shear Connectors used in Composite Beams", Journal of Korean Society of Steel Construction, Vol.26, No.3, pp.155-167, 2014 DOI |
8 | Oguejiofor, E. C., & Hosain, M. U., "A parametric study of perfobond rib shear connectors", Canadian Journal of Civil Engineering, Vol.21, No.4, pp.614-625, 1994 DOI |
9 | Medberry, S. B., & Shahrooz, B. M., "Perfobond shear connector for composite construction", Engineering Journal, Vol.39, No.1, pp.1048-1056, 2002 |
10 | Verissimo, G. S., Paes, J. L. R., Valente, I. B., Cruz, P. J. S., & Fakury, R. H. (2006). Design and dxperimental analysis of a new shear connector for steel and concrete composite structures. Proceedings of the 3rd International Conference on Bridge Maintenance, Safety and Management, Portugal, pp.68-72 |
11 | Vinh, C. T. H., Vinh, B, D., Le, V. P. N., Kim, I. T., Ahn, J. H., & Dao, D. K., "Shear Resistance Behaviors of an Newly Puzzle Shape of Crestbond Rib Shear Connector:An Experimental Study", Steel and Composite Structures, Vol.21, No.5, pp.1157-1182, 2016 DOI |
12 | Ushijima, Y., Hosaka, T., Mitsuki, K., Watanabe, H., Tachibana, Y., & Hiragi, H. (2001). An experimental study on shear characteristics of perfobond strip and its rational strength equations. Proceedings of the International Symposium on Connections between Steel and Concrete, Germany, pp.1066-1075 |
13 | Oh, M. H., Lee, M. S., Kim, Y. H., & Kim, M. H., "Experimental Study on the Shear Capacity of Cap Type Shear Connectors With Constant Intervals", Journal of Korean Association for Spatial Structures, Vol.18, No.2, pp.121-128, 2018 DOI |
14 | CEN prEN 1994-1-1:2004: Final Version of Editorial Group; Eurocode 4, "Design of composite steel and concrete structures. Part 1.1 : General rules and rules for buildings", Comite Europeen de Nomalisation (CEN), Belgium, 2004 |
15 | Candido-Martins, J. P. S., Costa-Veves, L. F., & Vellasco, P. C. G da S., "Experimental svaluation of the structural response of Perfobond shear connecors", Engineering Structures, Vol.32, No.8, pp.1976-1985, 2010 DOI |