Abstract
As the number of high-rise buildings increases, a mid-story isolation system has been proposed for high-rise buildings. Due to structural problems, an appropriate isolation layer displacement is required for an isolation system. In this study, the mid-story isolation system was designed and the seismic response of the structure was investigated by varying the yield strength and the horizontal stiffness of the seismic isolation system. To do this, a model with an isolation layer at the bottom of $15^{th}$ floor of a 20-story building was used as an example structure. Kobe(1995) and Nihonkai-Chubu(1983) earthquake are used as earthquake excitations. The yield strength and the horizontal stiffness of the seismic isolation system were varied to determine the seismic displacement and the story drift ratio of the structure. Based on the analytical results, as the yield strength and horizontal stiffness increase, the displacement of the isolation layer decreases. The story drift ratio decreases and then increases. The displacement of the isolation layer and the story drift ratio are inversely proportional. Increasing the displacement of the isolation layer to reduce the story drift ratio can cause the structure to become unstable. Therefore, an engineer should choose the appropriate yield strength and horizontal stiffness in consideration of the safety and efficiency of the structure when a mid-story isolation system for a high-rise building is designed.
Keywords
Characteristics of seismic isolation system; Seismic response reduction; Mid-story isolation; Tall building;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Lee, J. Y., Ju, Y. K., Kim, D. K., & Kim, S. D., "Application of Base Isolation System on the Middle Story of High-Rise Building", Proceeding of Autumn Annual Conference of the Architectural Institute of Korea Structure & Construction, Vol.28, No.1, pp.9-12, 2008
2 Kawamura, S., Sugisaki, R., Ogura, K., Maezawa, S., Tanaka, S., & Yajima, A., "Seismic isolation retrofit in Japan", 12WCEE 2000, pp.25-33, 2000
3 Hur, M. W., Ann, T. S., Son, J. W., & Kim, C. S., "Construction of Isolation Device for DONG-IL High-Vill New City", Review of Architecture and Building Science, Vol.54, No.5, pp.81-86, 2010
4 Tsuneki, Y., Torii, S., Murakami, K., & Sueoka, T., "Middle-Story Isolated Structural System of High-Rise Building", Proceeding of The 14th World Conference on Earthquake Engineering, 2008
5 Hur, M. W., Lee, Y. H., Kim, J. H., Park, C. Y., & Lee, S. H., "Seismic Isolation Effects by the Isolation Period of the Vertically Storyadded Remodeling Building", Proceeding of Spring Annual Conference of the Korea Concrete Institute, Vol.29, No.1, pp.705-706, 2017
6 Kim, K. Y., Lee, Y. R., Kim, H. S., & Kang, J. W., "Seismic Response Evaluation of High-Rise Buildings Considering Installation Story of the Mid-Story Isolation System", Journal of Korean Association for Spatial Structures, Vol.17, No.4, pp.85-92, 2017   DOI
7 Korea Professional Construction Newspaper, "'Lead Body (LRB)' 7.5 Can not resist earthquake", 2017.06
8 Cho, S. G., Yun, S. M., Kim, D. K., & Hong, K. J., "Analyses of Vertical Seismic Responses of Seismically Isolated Nuclear Power Plant Structures Supported by Lead Rubber Bearings", Journal of the Earthquake Engineering Society of Korea, Vol.19, No.3, pp.133-143, 2015   DOI
9 Kim, G. C., Kim, S. G., & Kang, J. W., "Application of Mid-story Isolation System for Seismic Response Reducing of Dome Structure", Journal of Korean Association for Spatial Structures, Vol.16, No.4, pp.37-44, 2016   DOI