Browse > Article
http://dx.doi.org/10.9712/KASS.2016.16.4.075

A Study on Horizontal Displacement Following Ability of Welded and Non-welded Building Hardware  

Lee, Don-Woo (School of Energy, Industrial Design & Architectural Engineering, Korea Univ. of Tech. & Edu.)
Kwak, Eui-Shin (School of Energy, Industrial Design & Architectural Engineering, Korea Univ. of Tech. & Edu.)
Shon, Su-Deok (School of Arch. Eng., Korea Univ. of Tech. & Edu.)
Lee, Seung-Jae (School of Arch. Eng., Korea Univ. of Tech. & Edu.)
Publication Information
Journal of Korean Association for Spatial Structures / v.16, no.4, 2016 , pp. 75-82 More about this Journal
Abstract
Building hardware joints are welded in most cases, which have risks of fire and explosion. Besides, the secondary damage of the destruction of the welded parts can be caused by the horizontal displacement of the structure due to earthquake or wind load. This paper compared the horizontal displacement following abilities of welded building hardware and non-welded building hardware. To do this, We conducted actual formation shake table test, and checked on the horizontal displacement following ability of structure by comparing their responses to earthquake load. We made the 2m-high framework to examine the responses of the actually constructed building hardwares, and analyzed the displacement responses of the welded-typed, non-welded-typed, and cruciform bracket building hardwares. We conducted the test by increasing acceleration rate until displacement reached 40mm corresponding to allowable relative story displacement II. The result of the test showed that the building hardware using welding work made cracking and breakage on welded connections of welded building hardware, but non-welded building hardware with no use of welding work and cruciform bracket building hardware make no problem, and that non-welded building hardware is superior to that of the welded building hardware in the horizontal displacement following ability due to earthquake or wind load.
Keywords
Building hardware; Non-welded typed; Cruciform bracket typed; Shake table test; Drift angle;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 E.S. Kwak, "The Study on Structural Performance Review of Displacement Absorbing Performance Improvement Exterior Panel Utilizing Moving Clips", Korea Institute for Structural Maintenance and Inspection Spring Annual Conference, Vol.20, No.1, pp.269-270, 2016
2 E.S. Kwak, "The Use of Moving Clips to Improve the Displacement Absorbing Performance of The Building Exterior Panel", Korea Institute for Structural Maintenance and Inspection Spring Annual Conference, Vol.20, No.1, pp.236-237, 2016
3 D.W. Lee, "The evaluation of Building Hardware Following the Structure's Horizontal Displacement", Architectural Institute of Korea 2016 Academic Conferences, Vol.36, No.2, pp.649-650, 2016
4 S.H. Min, "A Survey about Installation Trend for Exterior in Domestic", Korean Institute of Fire Science & Engineering Sping Annual Conference, pp.11-14, 2012
5 S.R. Lee, "An Experimental Study on the Fire Risk at Welding.Cutting Process", Journal of Korean Institute of Fire Sci. & Eng., Vol.26, No.3, pp.60-66, 2012
6 Ministry of Public Safety and Security National Fire Data System, http://www.nfds.go.kr/index.jsf
7 K.K. Chang and N.W. Park, "Development and Performance Evaluation of Under Cut Anchor Stone Curtain Wall Construction Method", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol.18, No.
8 Y.O. Lee, "A Study on the Economical Structual Design Method of Aluminum Curtain Wall System: Focusing on Mullion", Master Course, Seoul National University of science and Technology, 2011
9 D.K. Kim, "KBC Seismic Design Force for Nonstructural Element", Journal of the Korean Association for Spatial Structures, Vol.14, No.1, pp.77-84, 2014   DOI
10 Korea Meteorological Administration, http://www.kma.go.kr/index.jsp
11 Architectural Institute of Korea. (2009). Korean Building Code Structural(KBC2009).