SLIM AU(A plus U-shaped) composite beam was developed for reducing the story height in the residential buildings, and saving the cosrtuction cost of floor structures. Structural performance and economic feasibility of the composite beam have been sufficiently approved through the structural experiments and the analytical studies. However, the verification for fire safety is necessary for the practical application of the composite beam. The fire resistance tests with and without loading were performed for the fire safety verification, and the test results were summarized in this paper.
Keywords
Composite beam; Floor construction; Structural performance; Fire resistance;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Sha, W. (2001). Fire resistance of protected asymmetric slim floor beams, Proceedings of the eighth international conference on civil and structural engineering computing, Civil-Comp Press, Stirlingshire, Paper No. 67.
2 Buchanan, A. H. (2001). Structural design for fire safety, Wiley, Chichester, UK.
3 Ministry of Land, Infrastructure and Transport, Republic of Korea (2016). Korean Building Code.
4 International Standard Organization (1999), ISO 834-1: Fire resistance tests - Elements of building construction and materials - Part 1: General requirements.
5 International Standard Organization (2000), ISO 834-6: Fire resistance tests - Elements of building construction and materials - Part 6: Specific requirements for beams.
6 Kim, D.-B., Kim, Y.-H., Kang, C.-K., Kim, D.-J., and Choi, B.-J. (2016). "Shear resistance capacity of cap-type shear connector in the constant interval", Proceedings of Architectural Institute of Korea, Vol. 36, No. 1., pp. 321-322.
7 Kim, D.-B., Kim, Y.-H., Yom, K.-S., and Choi, B.-J. (2015). "Flexural strength evaluation of infilled-type composite beam (AU Beam) about the internal reinforcement", Proceedings of Architectural Institute of Korea, Vol. 35, No. 2., pp. 433-434.
8 Korean Standard Association (2014), KS F 2257-1: Methods fire resistance test for elements of building construction - General requirements.
9 Korean Standard Association (2014), KS F 2257-6: Methods fire resistance test for elements of building construction - Specific requirements for beams.