1 |
Kim YS, Jeong EC, Lee DU. Effectiveness of Copper Slag in Reducing Alkali-Silica Reaction Expansion. Journal of the Architectural Institute of Korea. 2009;25(7):71-8.
|
2 |
Chung HS, Yang KH, Kim HH. The Influence of the Quality and the Replacement Level of Recycled Aggregate on the Mechanical Properties of Concrete. Journal of the Architectural Institute of Korea. 2006 June;22(6):71-8.
|
3 |
Abdelrazig BEI, Main SD, Nowell DV. Hydration studies of modified OPC pastes by differential scanning calorimetry and thermogravimetry. J Thermal Analysis and caorimetry. 1992 Aug;38(3):495-504.
DOI
|
4 |
Parrott LJ, Geiker M, Gutteridge WA, Killoh D. Monitoring Portland cement hydration: Comparison of methods. Cement Concrete Research. 1990 Nov;20(6):919-26.
DOI
ScienceOn
|
5 |
Murakami K, Mino K, Harada H, Bhadeshia HKDH. Nonuniform recrystallisation in a mechanically alloyed Ni-base superalloy. Metallurgical and Materials Transactions A. 1933 May;24(5):1049-55.
|
6 |
Chou TS, Bhadeshia HKDH. Grain control in mechanically alloyed oxide dispersion strengthened MA957 steel. Materials Science and Technology. 1993 Oct:9(10):890-9.
DOI
ScienceOn
|
7 |
Ahn JC, Oh SG, Kang BH. Hydraulic Propertise of the Recycled Cement made of By-Product Cementitious Powder from Concrete Waste. Journal of the Architectural Institute of Korea. 2005 Sep;21(9):121-8.
|
8 |
Spoon CS, Shui ZH, Lam L. Effect of microstructure of ITZ on compressive strength of concrete prepared with recycled aggregate. Construction and Building Materials. 2004 July;18(6):461-8.
DOI
ScienceOn
|
9 |
Ahn JC, Lee JH, Kang BH. Propertise of Recycled Cement made of Cementituous Powder from Concrete Waster by Conditions of Burning. Journal of the Architectural Institute of Korea. 2003 Nov;19(11):109-16.
|
10 |
JoseManuel GS, josemanuel gomez. Shrinkage of Concrete with Replacement of Aggregate with Recycled Concrete Aggregate, A: Malhotra, V.M. editor. Innovation in Design with Emphasis on Seismic, Wind and Environmental Loading, Quality Control, and Innovation in Materials/Hot Weather Concreting. ACI international conference; 2002; Cancun, Maxico. USA: ACI; 2002. p. 475-95.
|
11 |
Powers TC. The Non-Evaporable Water Content of Hardened Cement Paste: Its Significance for Concrete Research and Its Determination. 1949 May; ASTM Bulletin 158. p. 68-76.
|
12 |
R. Tixier, R. Devaguptapu and B. Mobasher. The effect of copper slag on the hydration and mechanical properties of cementitious mixtures. Cement and Concrete Research. 1997;27(10):1569-80.
DOI
ScienceOn
|
13 |
Anderegg FO, Hubbel DS. The Rate of Hydration of Cement Clinker. Proceedings America Society for Testing and Materials. 1929 29(II). p. 554-69
|
14 |
Anderegg FO, Hubbel DS. The Rate of Hydration of Cement Clinker. Proceedings America Society for Testing and Materials. 1930 30(II). p. 572-780.
|
15 |
Oh SG, Hong YT. The Development of High Quality Recyclable Cement Made from Waste Concrete Using Micro Separating System. Journal of the Architectural Institute of Korea. 2007 Sep;23(9):167-74.
과학기술학회마을
|
16 |
Oh SG. A Study for the Hydration Recovery of Recycle Cement Using Waste Concrete Powder. Journal of the Architectural Institute of Korea. 2002 Oct:18(10):53-60.
과학기술학회마을
|
17 |
Bhatty J. A review of the application of thermal analysis to cement-admixture systems. Thermochim Acta. 1991 Oct;189(2):313-50.
DOI
ScienceOn
|
18 |
Sha W, O'Neilla EA, Guoa Z. Differential scanning calorimetry study of ordinary Portland cement. Cement and Concrete Research. 1999 Sep;29(9):1487-9.
DOI
ScienceOn
|