Browse > Article
http://dx.doi.org/10.5345/JKIC.2010.10.4.113

Study on the Engineering Properties of 150MPa Ultra-high Strength Concrete  

Jung, Sang-Jin (Department of Architecture Engineering, Dankook University)
Yoshihiro, Masuda (Architecture and Civil Eng. Dept., Utsunomiya University)
Kim, Woo-Jae (Architectural Engineering Reserch Group, POSCO E&C R&D Center)
Lee, Young-Ran (Architecture and Civil Eng. Dept., Utsunomiya University)
Kim, Seong-Deok (Graduate School, Dankook University)
Ha, Jung-Soo (Graduate School, Dankook University)
Publication Information
Journal of the Korea Institute of Building Construction / v.10, no.4, 2010 , pp. 113-122 More about this Journal
Abstract
In this study, 150MPa ultra-high-strength concrete was manufactured, and its performance was reviewed. As technically meaningful autogenous shrinkage reportedly occurs at a W/B ratio of 40% or less, although it occurs in all concrete regardless of the W/B ratio, the effects of the use of expansive admixture and shrinkage reducer, or of the friction and restraint of forms that may result in the effective reduction of autogenous shrinkage, were reviewed. As a result, considering the flow and strength characteristics, it was found that the slump flow time was shorter with expansive admixture, and shortest with shrinkage reducer. All specimens with $30kg/m^3$ expansive admixture showed high strength at early material age. Their strength decreased due to the expansion cracks when there was excessive use of expansive admixture, and the use of shrinkage reducer did not influence the change in the strength according to the material age. The expansive admixture had a shrinkage reduction effect of 80%, while the shrinkage reducer had a shrinkage reduction effect of 30%, indicating that the expansive admixture had a stronger effect. It seems that mixing the two will have a synergistic effect. The shrinkage reduction rate was highest when the W/B ratio was 20%. The form suppressed the expansion and shrinkage at the early period, and the demolding time did not significantly influence the shrinkage. The results of the study showed that the excessive addition of expansive admixture leads to expansion cracks, and the expansive admixture and shrinkage reducer have the highest shrinkage reduction effect when they are mixed.
Keywords
Ultra High Strength Concrete; Autogenous Shrinkage; Expansion Agent; Shrinkage Reducing Admixture;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Ishhikawa S, Tateyama S, Abe H, Shrinkage Characteristic of Ultra-High-Strength Concrete with Expansive Additive, Architectural Institute of Japan, Journal of Structural and Construction Engineering, A-1 2007:7-9
2 Han MC, An Analysis of Autogenous Shrinkage of Ultra-high Strength Concrete Added with Expansive admixture and Shrinkage Reducer, Proceedings of the Korean Institute of Building Construction, 2007;7(3):123-130   DOI
3 Umemoto M, Nonaka A, Urakaw K, Nishiura N, Yamada H, Nishida H, Kajita H, Experimental Study on Autogenous Shrinkage of Ultra High Strength Concrete Part4 Properties of Autogenous Shrinkage, Architectural Institute of Japan, Journal of Structural and Construction Engineering, 2007:261-262
4 Okamoto S, Yokota K, Matsuoka Y, Effect of Autogenous Shrinkage on Strain-Temperature Curve of Concrete at early age, Proceedings of annual Conference of the japan Society of Civil Engineers , 1995;50:678-679
5 Nishida H, Nonaka A, Urakawa K, Umemoto M, Nishiura N, Yamada H, Kajita H, Experimental Study on Autogenous Shrinkage of Ultra High Strength Concrete Part1 Outline of Experiment, Compressive Strength and Young's Modulus, Architectural Institute of Japan, Journal of Structural and Construction Engineering, 2007:255-256
6 Kuroiwa S , Namiki S, Jinnai h, Watanabe S, Nito N, Ishihara M, Autogenous shrinkage and self induced stress of 150MPa concrete using lime based admixture, Architectural Institute of Japan, Journal of Structural and Construction Engineering, A-1 2007:9-10
7 Takamori N, Katayose N, Nishida H, Teraoka M, Autogenous Shrinkage Behavior of Ultra-High-Strength Concrete with Expansive Additive and Shrinkage-Reducing Admixture. Part1 Outline of Experiment, Architectural Institute of Japan, Journal of Structural and Construction Engineering, A-1 2006:97-98
8 Nishimoto Y , Matsuda Y, Kawakaml H, A Study on the Decrease of Self-Shrinkage in Super-High-Strength Concrete(The Influence of Expansive Additive on Concrete Properties), Japan Concrete Institute Jounal, 1997;19(1):169-174
9 Lee HG ,Lee MK, Prediction Technology for Autogenous Shrinkage of Ultra-high Strength Concrete at an Early Material Age, Proceedings of Korea Concrete Institute 2005;17(4):34-40
10 Kuroiwa S, Watanabe S, Jinnai H, Satoru H, Autogenous shrinkage and self induced stress of 150MPa concrete, Architectural Institute of Japan, Journal of Structural and Construction Engineering, 2005:398-399
11 AItcin PC, Hight-Performance Concrete, E&FN Spon, London and New York, 1998.
12 Korea Concrete Institute, The Latest Concrete Engineering, Gimundang, 2005
13 Ichise K, Tuzuki M, Koshiro Y, Kawaguchi T, High-Strength Concrete over Fc100N/$mm^2$ for High-rise Reinforced Concrete Buildings Part.1 Fresfh and Strength Properties of High-Strength Concrete mixed Expansive additive, Architectural Institute of Japan, Journal of Structural and Construction Engineering, 2004:497-498