Browse > Article
http://dx.doi.org/10.5345/JKIC.2007.7.4.125

The Relationship Between the Quality of Surface Layer of Concrete Floor and the Defect of Self-Leveling Material - Evaluation Method about Surface Layer Quality of Concrete Floor Groundwork Corresponding to Defect in Self-leveling Material (Part II) -  

Kim, Doo-Ho (한국건설기술연구원)
Choi, Soo-Kyung (한서대학교 건축공학과)
Publication Information
Journal of the Korea Institute of Building Construction / v.7, no.4, 2007 , pp. 125-132 More about this Journal
Abstract
The use of Self-Leveling material is increasing recently. This paper assesses the quality of surface layer of concrete floor when Self-Leveling material is defective. The paper shows how to predict the defect of SL material before construction begins. The relationship between the quality of surface layer of concrete floor and the defect of SL material was determined and the quality of surface layer of concrete floor was then estimated. The relations between the quality of surface layer and the defect of SL material were determine considering surface strength, moisture, and consistency of surface layer. Absorbing amount was used as the indicator of consistency and the absorbing amount of test material was measured. Then the relations between the test material and surface strength were determined. Generally concrete floor with greater consistency has greater surface strength, however in this study, we hound that high impact concrete floor could have lower surface strength as the consistency gets bigger. The relations between the level of defect occurred in SL material and the quality of surface layer were examined and we clarified that the surface layer with lower consistency gets higher possibility to occur exfoliation in early stage, one or two weeks after constructing SL material. When the consistency is sufficient, the occurring situation of defect depends upon the moisture of surface layer. Little amount of moisture gets higher possibility not to occur the defect. As the amount increases, fissure generates and early exfoliation may occur. In addition, the level of fissure is highly related with the surface strength.
Keywords
Self-Leveling material; defect; concrete floor; quality of surface layer; evaluation method;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Yokoyama, Yokoi, Fundamental Study on Workability of High-streng th Concrete and Quality of Concrete Floor, Architectural Institute of Japan, Summaries of Technical Papers of Annual Meeting, pp.1067-1068, 2002. 8
2 Tanaka, Uchida, Ohmori, Bae K.S., Effect of Property of Substrate of Substrate Concrete on Blistering of Epoxy Resin Floor Coatings, Architectural Institute of Japan, Journal of Structural and Construction Engineering Transactions, Vol.493, pp.1-7, 1997. 3
3 Takemoto et al., Qualification of Surface Crack Damage of Sealants, Architectural Institute of Japan, Journal of Structural and Construction Engineering Transactions, Vol.606, pp.51-56, 2006. 8
4 Ishii et al., Experimental Study on Cracking of Concrete Slabs-on- Earth : Part 1. Purpose of Experimental, Architectural Institute of Japan, Summaries of Technical Papers of Annual Meeting, pp.329-330, 1999. 9
5 Yokoyama, Nishitani, Experimental Study on Impact of Execution Effort of Concrete Ground Work on Floor Quality and Maintenance Work, Architectural Institute of Japan, Journal of Structural and Construction Engineering Transactions, Vol.584, pp.29-36, 2004. 10
6 김두호, 최수경, 콘크리트 바닥 시험체의 크기가 SL재의 균열에 미치는 영향, 한국건축시공학회 논문집, 제7권 제2호, pp.1-8, 2007. 6   과학기술학회마을   DOI
7 Yokoyama, Yokoi, Concept of Quality Index on Surface Layer of Concrete Ground Work, Architectural Institute of Japan, Journal of Structural and Construction Engineering Transactions, Vol.580, pp.15-22, 2004. 6