Abstract
Acoustic Emission (AE) technology is an effective nondestructive testing for continuous monitoring of defect formation and failures in structural materials. This paper presents a source location model using Acoustic Emission (AE) sensors in a Pre-Stressed Concrete (PSC) beam and the evaluation of the model was performed through lab experiments. 54 AE events were made on the surface of the 5m-PSC beam using a Schmidt Hammer and arrival times were measured with 7AE sensors. The source location f3r each event was estimated using least squares. The results were compared with actual positions and the RMSE (Root Mean Square Errors) was about 2cm.
Keywords
Acoustic Emission; Source Location; PSC; Least Squares;
Citations & Related Records

Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 Cullington, D. W., MacNeil, D., Paulson, P. and Elliot, J. (2001) Continuous acoustic monitoring of grouted post-tensioned concrete bridges, NDT&E International, Vol. 34, pp. 95-105   DOI   ScienceOn
2 Halsall, A. P., Welch, W. E. and Trepanier, S. M. (1996), Acoustic monitoring technology for post-tensioned concrete structures, FIP Symposium 1996 on Post-tensioned Concrete Structures, The Concrete Society, pp. 483-491
3 Woodward, R. J. and Williams, F. W. (1988), Collapse of Ynys-s-Gwas bridge, West Glamorgan, Proceedings of Institute oj Civil Engineers, Part 1, Vol. 84, pp. 635-669
4 Mathy, B., Demars, P., Roisin, F. and Wouters, M. (1996), Investigation and strengthening study of twenty damaged bridges:a Belgiurn case history, Bridge Management: Inspection Maintenance and Repair, Proceedings of the 3rd International Conference, University of Surrey, pp. 658-666
5 권오양 (2001), 음향탐상(AE)기술의 현황과 활용방안, 안전기술지, http://home.kosha.net/~ndeteam/data/data13.hwp
6 Mikhail, E. M. (1976), Observations and least squares, University Press of America, New York, NY, pp. 110-118
7 Youn, Seck-Goo, Cho, Sun-Kyu and Kim, Eun-Kyum (2005), Acoustic emission technique for detection of corrosion-induced wire fracture, Key Engineering Materials, Vol. 297-300, pp. 2040-2045   DOI
8 The Concrete Society (1996), Durable bonded post-tensioned concrete bridges, Concrete Society Technical Report 47, TR047
9 Meng, M., Roberts, G. W., Dodson, A. H., Cosser, E., Barnes, J. and Rizos, C. (2004), Impact of GPS satellite and pseudolite geometry on structural deformation monitoring: analytical and empirical studies, Journal of Geodesy, Vol. 77, pp. 809-822   DOI
10 Mikhail, E. M., Bethel, J. S. and McGlone, J. C. (2001), Introduction to modern photogrammetry, John Wiley & Sons Inc., New York, pp. 414-422
11 Landis, E. N. and Shah, S. P. (1993), Signal analysis for quantitative AE testing, Nondestructive Testing from Structures Congress '93, Irvine, Calif, pp. 45-56