Browse > Article
http://dx.doi.org/10.12989/smm.2018.5.3.391

Strengthening of concrete structures with buckling braces and buckling restrained braces  

Mazloom, Moosa (Department of Civil Engineering, Shahid Rajaee Teacher Training University)
Pourhaji, Pardis (Department of Civil Engineering, Iran University of Science and Technology)
Farash, Abbas Moosa (Department of Civil Engineering, Shahid Rajaee Teacher Training University)
Sanati, Amir Hossein (Department of Civil Engineering, Shahid Rajaee Teacher Training University)
Publication Information
Structural Monitoring and Maintenance / v.5, no.3, 2018 , pp. 391-416 More about this Journal
Abstract
The purpose of this article is to strengthen concrete structures using buckling and non-buckling braces. Connection plates are modeled in three shapes including the effect of 1.5t hinge zone length, 2t one and without the zone (1.5t-CP, 2t-CP and WCP). According to the verification performed with ABAQUS software, the connection plates which are superior in ductility and strengthening are found. The results show adding steel braces in concrete moment frames increase the strength and stiffness of the structures up to about 12 and 3 times, respectively. The frame strength increased about 21 and 25 percent with considering the effect of 2t hinge length in connection plates compared to 1.5t-CPs and WCPs. Also the ductility of retrofitted frames with 2t-CP improved 2.06 times more than WCP ones. Thus, 2t-CP sample is the best choice for connecting steel braces to concrete moment frames for retrofitting them. Afterwards, optimum conditions for elemental coating in braces with no buckling are assessed. The length of concrete coatings could be reduced about 30 percent, and buckling did not occur. Therefore, the weight of restraining coating decreased, and its performance improved. It is worth noting that BRBs could be constructed with only steel materials, which have outer steel tubes too. In fact, only the square cross sections of the tube profiles are appropriate for removing the filler concrete, and the rectangular ones are prone to buckle around their weak axis.
Keywords
gusset plate connections; 2t hinge zone length; concrete frame; buckling restrained frame; steel tube;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Tagawa, Y., Aoki, H., Huang, T. and Masuda, H. (1992), "Experimental study of new seismic strengthening method for existing RC structure", Proceedings of the 10th World Conf. on Earthquake Engineering, Rotterdam.
2 Takeuchi, T., Hajjar, J., Matsui, R., Nishimoto, K. and Aiken, I. (2012), "Effect of local buckling core plate restraint in buckling restrained braces", Eng. Struct., 44, 304-311.   DOI
3 Takeuchi, T., Hajjar, J., Matsui, R., Nishimoto, K. and Aiken, ID. (2010), "Local buckling restraint condition for core plates in buckling restrained braces", J. Constr. Steel Res., 66, 139-149.   DOI
4 Truong, G.T., Kim, J.C. and Choi, K.K. (2017), "Seismic performance of reinforced concrete columns retrofitted by various methods", Eng. Struct., 134, 217-235.   DOI
5 Uang, C.M., Nakashima, M. and Tsai, K. (2004), "Research and application of buckling-restrained braced frames", Int. J. Steel Struct., 4, 301-313.
6 Watanabe, A., Hitomi, Y., Yaeki, E., Wada, A. and Fujimoto, M. (1988), "Properties of brace encased in buckling-restraining concrete and steel tube", Proceedings of the 9th World Conference on Earthquake Engineering, Japan, August.
7 Xie, Q. (2005), "State of the art of buckling-restrained braces in Asia", J. Constr. Steel Res., 61, 727-748.   DOI
8 Yazdi, H.M., Mosalman, M. and Soltani, A.M. (2018), "Seismic study of buckling restrained brace system without concrete infill", Int. J. Steel Struct., 18(1), 153-162.   DOI
9 Youssef, M.A., Ghaffarzadeh, H. and Nehdi, M. (2007), "Seismic performance of RC frames with concentric internal steel bracing", Eng. Struct., 29, 1561-1568.   DOI
10 Zhang, G., Chen, P., Zhao, Z. and Wu, J. (2018), "Experimental study on seismic performance of rocking buckling-restrained brace steel frame with liftable column base", J. Constr. Steel Res., 143, 291-306.   DOI
11 Ziqin, J., Yanlin, G., Bohao, Z. and Xuqiao, Z. (2015), "Influence of design parameters of buckling-restrained brace on its performance", J. Constr. Steel Res., 105, 139-150.   DOI
12 Viswanath, K.G., Prakash, K.B. and Anant, D. (2010), "Seismic analysis of steel braced reinforced concrete frames", Int. J. Civil Struct. Eng., 1(1), 114-122.
13 Badoux, M. and Jirsa, J.O. (1990), "Steel bracing of RC frames for seismic retrofitting", J. Structu. Eng.-ASCE, 116 (1), 55-74.   DOI
14 AISC-341 (2005), Seismic Provisions for Structural Steel Buildings including Supplement, American Institute of Steel Construction, Chicago, USA.
15 Astaneh-Asl, A., Cochran, M. and Sabelli, R. (2006), "Seismic detailing of gusset plates for special concentrically braced frames", Structural Steel Educational Council, Berkeley, California, USA.
16 Aydin, E., Sonmez, M. and Karabork, T. (2015), "Optimal placement of elastic steel diagonal braces using artificial bee colony algorithm", Steel Compos. Struct., 19(2), 349-368.   DOI
17 Bin, W. and Yang, M. (2015), "Buckling mechanism of steel core of buckling-restrained braces", J. Constr. Steel Res., 107, 61-69.   DOI
18 Black, C.J., Markis, N. and Aiken, I. (2004), "Component testing, seismic evaluation and characterization of buckling-restrained braces", J. Struct. Eng., 130(6), 880-894.   DOI
19 Bush, T.D., Jones, E.A. and Jirsa, J.O. (1991)," Behavior of RC frame strengthened using structural-steel bracing", J. Struct. Eng.- ASCE, 117(4), 1115-1126.   DOI
20 Chou, C.H. and Chen, S.H. (2010), "Subassemblage tests and finite element analyses of sandwiched buckling restrained braces", J. Constr. Steel Res., 8(32), 2108-2121.
21 FEMA 273 (1997), NEHRP guidelines for the seismic rehabilitation of buildings, Federal Emergency Management Agency, Building Seismic Safety Council, Washington D.C., USA.
22 Del Valle Calderon, E., Foutch, A., Hjelmstad, K., Figueroa-Gutierrez E. and Tena-Colunga A. (1988), "Seismic Retrofit of a RC building: A Case Study", Proceedings of the 9th World Conf. on Earthquake Engineering, Japan, August.
23 Elfath, A. and Ghobarah, A. (2000), "Behaviour of reinforced concrete frames rehabilitated with concentric steel bracing", Can. J. Civil Eng., 27(3), 433-444.   DOI
24 Elfath, A. and Ghobarah, A. (2001), "Rehabilitation of a reinforced concrete frames using eccentric steel bracing", Eng. Struct., 23, 745-755.   DOI
25 FEMA 274 (1997), NEHRP guidelines for the seismic rehabilitation of buildings, Federal Emergency Management Agency, Building Seismic Safety Council, Washington D.C., USA.
26 Ghaffarzadeh, H. and Maheri, M.R. (2006), "Mechanical compression release device in steel bracing system for retrofitting RC frames", Earthq. Eng. Eng.Vib., 5(1), 151-158.   DOI
27 Gholipour, M. and Mazloom, M. (2018), "Seismic response analysis of mega-scale buckling-restrained bracing systems in tall buildings", Adv. Comput. Des., 3(1), 17-34.   DOI
28 Goel, S.C. and Lee, H.S. (1992), "Seismic strengthening of structures by ductile steel bracing system", Proceedings of the 4thU.S. National Conference on Earthquake Engineering, Canada, May.
29 Guerrero, H., Escobar, J.A. and Gilmore, A. (2018), "Experimental damping on frame structures equipped with buckling-restrained braces (BRBs) working within their linear-elastic response", Soil Dynam. Earthq. Eng., 106, 196-203.   DOI
30 He, A., Cai, J., Chen, QJ., Liu, X., Xue, H. and Yu, C. (2017), "Axial compressive behaviour of steel-jacket retrofitted RC columns with recycled aggregate concrete", J. Constr. Build. Mater., 141, 501-516.   DOI
31 Hoveidae, N. and Rafezy, B. (2012), "Overall buckling behavior of all steel buckling restrained braces", J. Constr. Steel Res., 79, 151-158.   DOI
32 Maheri, M.R. and Akbari, R. (2003), "Seismic behaviour factor, R, for steel X-braced and knee-braced RC buildings", Eng. Struct., 25(12), 1505-1513.   DOI
33 Maheri, M.R. and Ghaffarzadeh, H. (2008), "Connection over strength in steel-braced RC frames", Eng. Struct., 30(12), 1938-1948.   DOI
34 Maheri, M.R. and Sahebi, A. (1997), "Use of steel bracing in reinforced concrete frames", Eng. Struct., 19(12), 1018-1024.   DOI
35 Maheri, M.R. and Memarzadeh, P. (2001), "Nonlinear analysis of steel braced concrete frames", Proceedings of the 1st International Conference on Concrete & Development (1ICCD), Tehran, April.
36 Massumin, A. and Absalan, M. (2013), "Interaction between bracing system and moment resisting frame in braced RC frames", Arch. Civil Mecha. Eng., 13, 260-268.   DOI
37 Mazloom, M. (2010), "Effect of shear wall cracking on soft story phenomenon", Int. J. Civil Eng., 8(3), 276-285.
38 Mazloom, M. and Salehi, V. (2017), "Studying the behavior of central gusset plate connections on inverted V-braces", J. Civil Environ. Eng., 46(2).
39 Mirtaheri, M., Sehat, S. and Nazeryan, M. (2018), "Improving the behavior of buckling restrained braces through obtaining optimum steel core length", Struct. Eng. Mech., 65 (4), 401-408.   DOI
40 Mohammadi, H., Toufigh V., Golafshani, A. and Arzeytoon, A. (2018), "Performance-based assessment of an innovative braced tube system for tall building", Bull. Earthq. Eng., 16(2), 731-752.   DOI
41 Ozel, A.E and Guneyisi, E.M. (2011), "Effects of eccentric steel bracing systems on seismic fragility curves of mid-rise R/C buildings: a case study", Struct.Saf., 33(1), 82-95.   DOI
42 Maheri, M.R., Kousari, R. and Razazan, M. (2003), "Pushover tests on steel X-braced and knee-braced RC frames", Eng. Struct., 25(13), 1697-1705.   DOI
43 Piedrafita, D., Cahis, X., Simon, E. and Comas, J. (2015), "A new perforated core buckling restrained brace", Eng. Struct., 85, 118-126.   DOI
44 Qin, X., Zhen, Z., Huang, J. and Shao-Ping, M. (2016), "Influence of tube length tolerance on seismic responses of multi-story buildings with dual-tube self-centering buckling restrained braces", Eng. Struct., 116, 26-39.   DOI
45 Quan, G., Alessandro, Z., Peng, Y. and Andrea, D. (2014), "Effect of buckling-restrained brace model parameters on seismic structural response", J. Constr. Steel Res., 98, 100-113.   DOI
46 Rahai, A. and Lashgari, M. (2006), "Seismic strengthening of nine-story RC building using concentric and buckling-restrained bracing", Proceedings of the 31st Conference on Our World in Concrete & Structures, Singapore, August.
47 Sekiguchi, I. (1988), "Seismic Strengthening of an Existing Steel Reinforced Concrete City Office Building in Shizuoka", Japan. Proceedings of the 9th World Conf. on Earthquake Engineering, Japan, Agusut.
48 Shin, J., Scott, D., Stewart, L., Yang, C., Wright. T. and DesRoches. R. (2016), "Dynamic response of a full-scale reinforced concrete building frame retrofitted with FRP column jackets", Eng. Struct., 125, 244-253.   DOI