Browse > Article
http://dx.doi.org/10.3348/kjr.2016.17.4.489

Performance of Screening Mammography: A Report of the Alliance for Breast Cancer Screening in Korea  

Lee, Eun Hye (Department of Radiology, Bucheon Hospital, Soonchunhyang University College of Medicine)
Kim, Keum Won (Department of Radiology, Konyang University Hospital, Konyang University College of Medicine)
Kim, Young Joong (Department of Radiology, Konyang University Hospital, Konyang University College of Medicine)
Shin, Dong-Rock (Department of Radiology, Gangneung Asan Hospital, University of Ulsan College of Medicine)
Park, Young Mi (Department of Radiology, Busan Paik Hospital, Inje University College of Medicine)
Lim, Hyo Soon (Department of Radiology, Chonnam National University Hwasun Hospital, Chonnam National University College of Medicine)
Park, Jeong Seon (Department of Radiology, Hanyang University Hospital, Hanyang University College of Medicine)
Kim, Hye-Won (Department of Radiology, Wonkwang University Hospital, Wonkwang University School of Medicine)
Kim, You Me (Department of Radiology, Dankook University Hospital, Dankook University College of Medicine)
Kim, Hye Jung (Department of Radiology, Kyungpook National University Hospital, Kyungpook National University College of Medicine)
Jun, Jae Kwan (National Cancer Control Institute, National Cancer Center)
Publication Information
Korean Journal of Radiology / v.17, no.4, 2016 , pp. 489-496 More about this Journal
Abstract
Objective: To analyze the diagnostic accuracy and trend in screening mammography in Korea. Materials and Methods: We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), and interval cancer rate (ICR). Changes in the performance indicators were calculated as the annual percent change with 95% confidence interval (CI). Results: We enrolled 128756 cases from 10 hospitals from 2005 to 2010. The recall rate was 19.1% with a downward trend over time (-12.1% per year; 95% CI, -15.9 to -8.2). The CDR was 2.69 per 1000 examinations, without a significant trend. The PPV was 1.4% with an upward trend (20.8% per year; 95% CI, 15.2 to 26.7). The sensitivity was 86.5% without a significant trend, whereas the specificity was 81.1% with an upward trend (3.3% per year; 95% CI, 2.1 to 4.5). The FPR was 18.9% with a downward trend (-12.4% per year; 95% CI, -16.2 to -8.4). The ICR was 0.5 per 1000 negative examinations without a significant trend. There were institutional variations in the diagnostic accuracy and trend except for the CDR, sensitivity, and ICR. Conclusion: The sensitivity and CDR of screening mammography in the ABCS-K from 2005 to 2010 were compatible with those for Western women. The recall rate, PPV and specificity, however, were suboptimal, although they showed significant improvements over this period. A further analysis is required to explain institutional variations.
Keywords
Breast; Breast neoplasms; Mammography; Mass screening;
Citations & Related Records
Times Cited By KSCI : 9  (Citation Analysis)
연도 인용수 순위
1 Jung KW, Won YJ, Kong HJ, Oh CM, Cho H, Lee DH, et al. Cancer statistics in Korea: incidence, mortality, survival, and prevalence in 2012. Cancer Res Treat 2015;47:127-141   DOI
2 Kim Y, Jun JK, Choi KS, Lee HY, Park EC. Overview of the National Cancer screening programme and the cancer screening status in Korea. Asian Pac J Cancer Prev 2011;12:725-730
3 Suh M, Choi KS, Lee YY, Jun JK. Trends in cancer screening rates among Korean men and women: results from the Korean National Cancer screening survey, 2004-2012. Cancer Res Treat 2013;45:86-94   DOI
4 Kang MH, Park EC, Choi KS, Suh M, Jun JK, Cho E. The National Cancer Screening Program for breast cancer in the Republic of Korea: is it cost-effective? Asian Pac J Cancer Prev 2013;14:2059-2065   DOI
5 Choi NM, Lee AL, Lee HK, Yi BH, Cha JG. Mammogrphic screening provided by the National Health Insurance Corporation: a 1 year audit in a secondary medical institution. J Korean Soc Radiol 2009;60:51-55   DOI
6 D'Orsi CJ, Bassett LW, Berg WA, Feig SA, Jackson VP, KopanDB, et al. BI-RADS: mammography. In: D'Orsi CJ, Mendelson EB, Ikeda DM, eds. $BI-RADS^{(R)}$ breast imaging and reporting data system: breast imaging atlas, 4th ed. Reston: American College of Radiology, 2003
7 Kim HJ, Fay MP, Feuer EJ, Midthune DN. Permutation tests for joinpoint regression with applications to cancer rates. Stat Med 2000;19:335-351   DOI
8 Ahn HS, Kim SM, Jang M, Yun BL, Kim B, Ko ES, et al. A new full-field digital mammography system with and without the use of an advanced post-processing algorithm: comparison of image quality and diagnostic performance. Korean J Radiol 2014;15:305-312   DOI
9 Kim SA, Chang JM, Cho N, Yi A, Moon WK. Characterization of breast lesions: comparison of digital breast tomosynthesis and ultrasonography. Korean J Radiol 2015;16:229-238   DOI
10 Ko SY, Kim EK, Kim MJ, Moon HJ. Mammographic density estimation with automated volumetric breast density measurement. Korean J Radiol 2014;15:313-321   DOI
11 Lee EH, Jung SE. Current status of radiologists' part-time services in mammography. J Korean Soc Breast Screen 2012;9:142-147
12 Suzuki A, Kuriyama S, Kawai M, Amari M, Takeda M, Ishida T, et al. Age-specific interval breast cancers in Japan: estimation of the proper sensitivity of screening using a population-based cancer registry. Cancer Sci 2008;99:2264-2267   DOI
13 Sickles EA, D'Orsi CJ. ACR $BI-RADS^{(R)}$ follow-up and outcome monitoring. In: D'Orsi CJ, Sickles EA, Mendelson EB, Morris EA, eds. ACR $BI-RADS^{(R)}$ atlas breast imaging reporting and data system. Reston, VA: American College of Radiology, 2013
14 Mandelson MT, Oestreicher N, Porter PL, White D, Finder CA, Taplin SH, et al. Breast density as a predictor of mammographic detection: comparison of interval-and screen-detected cancers. J Natl Cancer Inst 2000;92:1081-1087   DOI
15 Stomper PC, D'Souza DJ, DiNitto PA, Arredondo MA. Analysis of parenchymal density on mammograms in 1353 women 25-79 years old. AJR Am J Roentgenol 1996;167:1261-1265   DOI
16 Lee EH, Jun JK, Kim YM, Bae K, Hwang KW, Choi BB, et al. Mammography boot camp to improve a quality of national cancer screening program in Korea: a report about a test run in 2012. J Korean Soc Breast Screen 2013;10:162-168
17 Lee EH, Jun JK, Jung SE, Kim YM, Choi N. The efficacy of mammography boot camp to improve the performance of radiologists. Korean J Radiol 2014;15:578-585   DOI