Computer-Aided Detection of Malignant Lung Nodules on Chest Radiographs: Effect on Observers' Performance  

Lee, Kyung Hee (Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center)
Goo, Jin Mo (Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center)
Park, Chang Min (Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center)
Lee, Hyun Ju (Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center)
Jin, Kwang Nam (Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center)
Publication Information
Korean Journal of Radiology / v.13, no.5, 2012 , pp. 564-571 More about this Journal
Abstract
Objective: To evaluate the effect of computer-aided detection (CAD) system on observer performance in the detection of malignant lung nodules on chest radiograph. Materials and Methods: Two hundred chest radiographs (100 normal and 100 abnormal with malignant solitary lung nodules) were evaluated. With CT and histological confirmation serving as a reference, the mean nodule size was 15.4 mm (range, 7-20 mm). Five chest radiologists and five radiology residents independently interpreted both the original radiographs and CAD output images using the sequential testing method. The performances of the observers for the detection of malignant nodules with and without CAD were compared using the jackknife free-response receiver operating characteristic analysis. Results: Fifty-nine nodules were detected by the CAD system with a false positive rate of 1.9 nodules per case. The detection of malignant lung nodules significantly increased from 0.90 to 0.92 for a group of observers, excluding one first-year resident (p = 0.04). When lowering the confidence score was not allowed, the average figure of merit also increased from 0.90 to 0.91 (p = 0.04) for all observers after a CAD review. On average, the sensitivities with and without CAD were 87% and 84%, respectively; the false positive rates per case with and without CAD were 0.19 and 0.17, respectively. The number of additional malignancies detected following true positive CAD marks ranged from zero to seven for the various observers. Conclusion: The CAD system may help improve observer performance in detecting malignant lung nodules on chest radiographs and contribute to a decrease in missed lung cancer.
Keywords
Computer-aided detection; Lung nodules; Lung cancer; Chest radiograph;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Muhm JR, Miller WE, Fontana RS, Sanderson DR, Uhlenhopp MA. Lung cancer detected during a screening program using four-month chest radiographs. Radiology 1983;148:609-615   DOI
2 Austin JH, Romney BM, Goldsmith LS. Missed bronchogenic carcinoma: radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect. Radiology 1992;182:115-122   DOI
3 Monnier-Cholley L, Arrive L, Porcel A, Shehata K, Dahan H, Urban T, et al. Characteristics of missed lung cancer on chest radiographs: a French experience. Eur Radiol 2001;11:597-605   DOI   ScienceOn
4 Quekel LG, Kessels AG, Goei R, van Engelshoven JM. Miss rate of lung cancer on the chest radiograph in clinical practice. Chest 1999;115:720-724   DOI   ScienceOn
5 Choi EJ, Jin GY, Han YM, Lee YS, Kweon KS. Solitary pulmonary nodule on helical dynamic CT scans: analysis of the enhancement patterns using a computer-aided diagnosis (CAD) system. Korean J Radiol 2008;9:401-408   DOI   ScienceOn
6 Song KD, Chung MJ, Kim HC, Jeong SY, Lee KS. Usefulness of the CAD system for detecting pulmonary nodule in real clinical practice. Korean J Radiol 2011;12:163-168   DOI   ScienceOn
7 Goo JM. A computer-aided diagnosis for evaluating lung nodules on chest CT: the current status and perspective. Korean J Radiol 2011;12:145-155   DOI   ScienceOn
8 Kakeda S, Moriya J, Sato H, Aoki T, Watanabe H, Nakata H, et al. Improved detection of lung nodules on chest radiographs using a commercial computer-aided diagnosis system. AJR Am J Roentgenol 2004;182:505-510   DOI   ScienceOn
9 Shiraishi J, Li F, Doi K. Computer-aided diagnosis for improved detection of lung nodules by use of posterior-anterior and lateral chest radiographs. Acad Radiol 2007;14:28-37   DOI   ScienceOn
10 Bley TA, Baumann T, Saueressig U, Pache G, Treier M, Schaefer O, et al. Comparison of radiologist and CAD performance in the detection of CT-confirmed subtle pulmonary nodules on digital chest radiographs. Invest Radiol 2008;43:343-348   DOI   ScienceOn
11 He Q, He W, Wang K, Ma D. Effect of multiscale processing in digital chest radiography on automated detection of lung nodule with a computer assistance system. J Digit Imaging 2008;21 Suppl 1:S164-S170   DOI
12 Kasai S, Li F, Shiraishi J, Doi K. Usefulness of computer-aided diagnosis schemes for vertebral fractures and lung nodules on chest radiographs. AJR Am J Roentgenol 2008;191:260-265   DOI   ScienceOn
13 Li F, Engelmann R, Metz CE, Doi K, MacMahon H. Lung cancers missed on chest radiographs: results obtained with a commercial computer-aided detection program. Radiology 2008;246:273-280   DOI
14 van Beek EJ, Mullan B, Thompson B. Evaluation of a realtime interactive pulmonary nodule analysis system on chest digital radiographic images: a prospective study. Acad Radiol 2008;15:571-575   DOI   ScienceOn
15 White CS, Flukinger T, Jeudy J, Chen JJ. Use of a computeraided detection system to detect missed lung cancer at chest radiography. Radiology 2009;252:273-281   DOI   ScienceOn
16 de Hoop B, De Boo DW, Gietema HA, van Hoorn F, Mearadji B, Schijf L, et al. Computer-aided detection of lung cancer on chest radiographs: effect on observer performance. Radiology 2010;257:532-540   DOI   ScienceOn
17 Chakraborty DP. Analysis of location specific observer performance data: validated extensions of the jackknife freeresponse (JAFROC) method. Acad Radiol 2006;13:1187-1193   DOI   ScienceOn
18 Li Q, Li F, Shiraishi J, Katsuragawa S, Sone S, Doi K. Investigation of new psychophysical measures for evaluation of similar images on thoracic computed tomography for distinction between benign and malignant nodules. Med Phys 2003;30:2584-2593   DOI   ScienceOn
19 Giger ML, Chan HP, Boone J. Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM. Med Phys 2008;35:5799-5820   DOI   ScienceOn