Browse > Article
http://dx.doi.org/10.3348/kjr.2012.13.3.307

Safety and Efficacy of Ultrasound-Guided Fiducial Marker Implantation for CyberKnife Radiation Therapy  

Kim, Jae-Hyun (Department of Radiology, Soonchunhyang University Seoul Hospital)
Hong, Seong-Sook (Department of Radiology, Soonchunhyang University Seoul Hospital)
Kim, Jung-Hoon (Department of Radiology, Soonchunhyang University Seoul Hospital)
Park, Hyun-Jeong (Department of Radiology, Soonchunhyang University Seoul Hospital)
Chang, Yun-Woo (Department of Radiology, Soonchunhyang University Seoul Hospital)
Chang, A-Ram (Department of Radiation Oncology, Soonchunhyang University Seoul Hospital)
Kwon, Seok-Beom (Department of Neurology, Hallym University College of Medicine)
Publication Information
Korean Journal of Radiology / v.13, no.3, 2012 , pp. 307-313 More about this Journal
Abstract
Objective: To evaluate the safety and technical success rate of an ultrasound-guided fiducial marker implantation in preparation for CyberKnife radiation therapy. Materials and Methods: We retrospectively reviewed 270 percutaneous ultrasound-guided fiducial marker implantations in 77 patients, which were performed from June 2008 through March 2011. Of 270 implantations, 104 were implanted in metastatic lymph nodes, 96 were in the liver, 39 were in the pancreas, and 31 were in the prostate. During and after the implantation, major and minor procedure-related complications were documented. We defined technical success as the implantation enabling adequate treatment planning and CT simulation. Results: The major and minor complication rates were 1% and 21%, respectively. One patient who had an implantation in the liver suffered severe abdominal pain, biloma, and pleural effusion, which were considered as major complication. Abdominal pain was the most common complication in 11 patients (14%). Among nine patients who had markers inserted in the prostate, one had transient hematuria for less than 24 hours, and the other experienced transient voiding difficulty. Of the 270 implantations, 261 were successful (97%). The reasons for unsuccessful implantations included migration of fiducial markers (five implantations, 2%) and failure to discriminate the fiducial markers (three implantations, 1%). Among the unsuccessful implantation cases, six patients required additional procedures (8%). Conclusion: The symptomatic complications following ultrasound-guided percutaneous implantation of fiducial markers are relatively low. However, careful consideration of the relatively higher rate of migration and discrimination failure is needed when performing ultrasound-guided percutaneous implantations of fiducial markers.
Keywords
Fiducial marker; Radiation oncology; Ultrasonography; interventional; Imaging-guided radiation therapy;
Citations & Related Records

Times Cited By Web Of Science : 1  (Related Records In Web of Science)
연도 인용수 순위
  • Reference
1 Cardella JF, Bakal CW, Bertino RE, Burke DR, Drooz A, Haskal Z, et al. Quality improvement guidelines for imageguided percutaneous biopsy in adults. J Vasc Interv Radiol 2003;14:S227-S230   DOI   ScienceOn
2 Chang SD, Main W, Martin DP, Gibbs IC, Heilbrun MP. An analysis of the accuracy of the CyberKnife: a robotic frameless stereotactic radiosurgical system. Neurosurgery 2003;52:140- 146; discussion 146-147
3 Sotiropoulou E, Stathochristopoulou I, Stathopoulos K, Verigos K, Salvaras N, Thanos L. CT-guided fiducial placement for cyberknife stereotactic radiosurgery: an initial experience. Cardiovasc Intervent Radiol 2010;33:586-589   DOI   ScienceOn
4 Kothary N, Heit JJ, Louie JD, Kuo WT, Loo BW Jr, Koong A, et al. Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy. J Vasc Interv Radiol 2009;20:235-239   DOI   ScienceOn
5 Leskell L. Stereotaxis and Radiosurgery: an operative system. Springfield, IL: Charles C. Thomas, 1971:5-51
6 Lax I, Blomgren H, Larson D, Näslund I. Extracranial stereotactic radiosurgery of localized targets. J Radiosurg 1998;1:135-148   DOI
7 Chang SD, Murphy MI, Martin DP, Hancock SL, Doty JR, Adler JR. Image-guided robotic radiosurgery: clinical and radiographic results with the CyberKnife. Radiosurgery 1999;3:23-3
8 Shirato H, Harada T, Harabayashi T, Hida K, Endo H, Kitamura K, et al. Feasibility of insertion/implantation of 2.0-mmdiameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. Int J Radiat Oncol Biol Phys 2003;56:240-24   DOI   ScienceOn
9 Adler JR Jr, Murphy MJ, Chang SD, Hancock SL. Image-guided robotic radiosurgery. Neurosurgery 1999;44:1299-1306; discussion 1306-1307
10 Chang SD, Adler JR. Robotics and radiosurgery--the cyberknife. Stereotact Funct Neurosurg 2001;76:204-208   DOI   ScienceOn
11 Ryu SI, Chang SD, Kim DH, Murphy MJ, Le QT, Martin DP, et al. Image-guided hypo-fractionated stereotactic radiosurgery to spinal lesions. Neurosurgery 2001;49:838-846
12 Berbeco RI, Nishioka S, Shirato H, Chen GT, Jiang SB. Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates. Phys Med Biol 2005;50:3655-3667   DOI   ScienceOn
13 Kothary N, Dieterich S, Louie JD, Chang DT, Hofmann LV, Sze DY. Percutaneous implantation of fiducial markers for imaging-guided radiation therapy. AJR Am J Roentgenol 2009;192:1090-1096   DOI   ScienceOn