Browse > Article
http://dx.doi.org/10.3348/kjr.2011.12.4.473

Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip  

Song, Ji-Soo (Department of Vascular Radiology and Interventional Radiology, Chonbuk National University Medical School)
Kwak, Hyo-Sung (Department of Vascular Radiology and Interventional Radiology, Chonbuk National University Medical School)
Chung, Gyung-Ho (Department of Vascular Radiology and Interventional Radiology, Chonbuk National University Medical School)
Publication Information
Korean Journal of Radiology / v.12, no.4, 2011 , pp. 473-480 More about this Journal
Abstract
Objective: We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional angiography. Materials and Methods: In 16 patients (mean age, 59.4 years) with acute bleeding ulcers (13 gastric ulcers, 2 duodenal ulcers, 1 malignant ulcer), a metallic clip was placed via gastroscopy and this had been preceded by routine endoscopic treatment. The metallic clip was placed in the fibrous edge of the ulcer adjacent to the bleeding point. All patients had negative results from their angiographic studies. To localize the bleeding focus, rotational angiography and high pressure angiography as close as possible to the clip were used. Results: Of the 16 patients, seven (44%) had positive results after high pressure angiography as close as possible to the clip and they underwent transcatheter arterial embolization (TAE) with microcoils. Nine patients without extravasation of contrast medium underwent TAE with microcoils as close as possible to the clip. The bleeding was stopped initially in all patients after treatment of the feeding artery. Two patients experienced a repeat episode of bleeding two days later. Of the two patients, one had subtle oozing from the ulcer margin and that patient underwent endoscopic treatment. One patient with malignant ulcer died due to disseminated intravascular coagulation one month after embolization. Complete clinical success was achieved in 14 of 16 (88%) patients. Delayed bleeding or major/minor complications were not noted. Conclusion: Rotational angiography after marking with a metallic clip helps to localize accurately the bleeding focus and thus to embolize the vessel correctly.
Keywords
Gastrointestinal bleeding; Embolization; Angiography;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
Times Cited By Web Of Science : 2  (Related Records In Web of Science)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Rockall TA, Logan RF, Devlin HB, Northfield TC. Incidence of and mortality from acute upper gastrointestinal haemorrhage in the United Kingdom. Steering Committee and members of the National Audit of Acute Upper Gastrointestinal Haemorrhage. BMJ 1995;311:222-226   DOI   ScienceOn
2 Non-variceal upper gastrointestinal haemorrhage: guidelines. Gut 2002;51 Suppl 4:iv1-6   DOI
3 Binmoeller KF, Thonke F, Soehendra N. Endoscopic hemoclip treatment for gastrointestinal bleeding. Endoscopy 1993;25:167-170   DOI   ScienceOn
4 Saltzman JR, Strate LL, Di Sena V, Huang C, Merrifield B, Ookubo R, et al. Prospective trial of endoscopic clips versus combination therapy in upper GI bleeding (PROTECCT-UGI bleeding). Am J Gastroenterol 2005;100:1503-1508   DOI   ScienceOn
5 Longstreth GF. Epidemiology of hospitalization for acute upper gastrointestinal hemorrhage: a population-based study. Am J Gastroenterol 1995;90:206-210
6 Rupp T, Singh S, Waggenspack W. Gastrointestinal hemorrhage: The prehospital recognition, assessment & management of patients with a GI bleed. JEMS 2004;29:80-81, 83-95; quiz 96-87
7 Hung CF, Cheng TL, Wu RH, Teng CF, Chang WT. A novel bidirectional expression system for simultaneous expression of both the protein-coding genes and short hairpin RNAs in mammalian cells. Biochem Biophys Res Commun 2006;339:1035-1042   DOI   ScienceOn
8 Aina R, Oliva VL, Therasse E, Perreault P, Bui BT, Dufresne MP, et al. Arterial embolotherapy for upper gastrointestinal hemorrhage: outcome assessment. J Vasc Interv Radiol 2001;12:195-200   DOI   ScienceOn
9 Schenker MP, Duszak R Jr, Soulen MC, Smith KP, Baum RA, Cope C, et al. Upper gastrointestinal hemorrhage and transcatheter embolotherapy: clinical and technical factors impacting success and survival. J Vasc Interv Radiol 2001;12:1263-1271   DOI   ScienceOn
10 Jae HJ, Chung JW, Jung AY, Lee W, Park JH. Transcatheter arterial embolization of nonvariceal upper gastrointestinal bleeding with N-butyl cyanoacrylate. Korean J Radiol 2007;8:48-56   DOI   ScienceOn
11 Loffroy R, Rao P, Ota S, De Lin M, Kwak BK, Geschwind JF. Embolization of acute nonvariceal upper gastrointestinal hemorrhage resistant to endoscopic treatment: results and predictors of recurrent bleeding. Cardiovasc Intervent Radiol 2010;33:1088-1100   DOI   ScienceOn
12 Hastings GS. Angiographic localization and transcatheter treatment of gastrointestinal bleeding. Radiographics 2000;20:1160-1168   DOI
13 Burke SJ, Golzarian J, Weldon D, Sun S. Nonvariceal upper gastrointestinal bleeding. Eur Radiol 2007;17:1714-1726   DOI   ScienceOn
14 Drooz AT, Lewis CA, Allen TE, Citron SJ, Cole PE, Freeman NJ, et al. Quality improvement guidelines for percutaneous transcatheter embolization. SCVIR Standards of Practice Committee. Society of Cardiovascular & Interventional Radiology. J Vasc Interv Radiol 1997;8:889-895   DOI   ScienceOn
15 Kim JH, Shin JH, Yoon HK, Chae EY, Myung SJ, Ko GY, et al. Angiographically negative acute arterial upper and lower gastrointestinal bleeding: incidence, predictive factors, and clinical outcomes. Korean J Radiol 2009;10:384-390   DOI   ScienceOn
16 Malden ES, Hicks ME, Royal HD, Aliperti G, Allen BT, Picus D. Recurrent gastrointestinal bleeding: use of thrombolysis with anticoagulation in diagnosis. Radiology 1998;207:147-151   DOI
17 Chung IK, Ham JS, Kim HS, Park SH, Lee MH, Kim SJ. Comparison of the hemostatic efficacy of the endoscopic hemoclip method with hypertonic saline-epinephrine injection and a combination of the two for the management of bleeding peptic ulcers. Gastrointest Endosc 1999;49:13-18   DOI   ScienceOn
18 Bloomfeld RS, Smith TP, Schneider AM, Rockey DC. Provocative angiography in patients with gastrointestinal hemorrhage of obscure origin. Am J Gastroenterol 2000;95:2807-2812   DOI   ScienceOn
19 Kim CY, Suhocki PV, Miller MJ Jr, Khan M, Janus G, Smith TP. Provocative mesenteric angiography for lower gastrointestinal hemorrhage: results from a single-institution study. J Vasc Interv Radiol 2010;21:477-483   DOI   ScienceOn
20 Ryan JM, Key SM, Dumbleton SA, Smith TP. Nonlocalized lower gastrointestinal bleeding: provocative bleeding studies with intraarterial tPA, heparin, and tolazoline. J Vasc Interv Radiol 2001;12:1273-1277   DOI   ScienceOn
21 Cipolletta L, Bianco MA, Marmo R, Rotondano G, Piscopo R, Vingiani AM, et al. Endoclips versus heater probe in preventing early recurrent bleeding from peptic ulcer: a prospective and randomized trial. Gastrointest Endosc 2001;53:147-151   DOI   ScienceOn
22 Eriksson LG, Sundbom M, Gustavsson S, Nyman R. Endoscopic marking with a metallic clip facilitates transcatheter arterial embolization in upper peptic ulcer bleeding. J Vasc Interv Radiol 2006;17:959-964   DOI   ScienceOn
23 Hagen G, Wadstrom J, Eriksson LG, Magnusson P, Magnusson M, Magnusson A. Three-dimensional rotational angiography of transplanted renal arteries: influence of an extended angle of rotation on beam-hardening artifacts. Acta Radiol 2005;46:170-176   DOI   ScienceOn
24 Bucek RA, Reiter M, Dirisamer A, Kettenbach J, Lammer J. [Three-dimensional digital rotation angiography for embolization therapy of uterine leiomyomas: first results]. Rofo 2004;176:1001-1004   DOI   ScienceOn
25 Tanigawa N, Komemushi A, Kojima H, Kariya S, Sawada S. Three-dimensional angiography using rotational digital subtraction angiography: usefulness in transarterial embolization of hepatic tumors. Acta Radiol 2004;45:602-607   DOI   ScienceOn
26 Kakeda S, Korogi Y, Ohnari N, Moriya J, Oda N, Nishino K, et al. Usefulness of cone-beam volume CT with flat panel detectors in conjunction with catheter angiography for transcatheter arterial embolization. J Vasc Interv Radiol 2007;18:1508-1516   DOI   ScienceOn
27 Virmani S, Ryu RK, Sato KT, Lewandowski RJ, Kulik L, Mulcahy MF, et al. Effect of C-arm angiographic CT on transcatheter arterial chemoembolization of liver tumors. J Vasc Interv Radiol 2007;18:1305-1309   DOI   ScienceOn