Dual-Energy Subtraction Imaging for Diagnosing Vocal Cord Paralysis with Flat Panel Detector Radiography |
Machida, Haruhiko
(Department of Radiology, Tokyo Women's Medical University Medical Center East)
Yoda, Keiko (Department of Otolarygology, Tokyo Women's Medical University Medical Center East) Arai, Yasuko (Department of Otolarygology, Tokyo Women's Medical University Medical Center East) Nishida, Suguru (Department of Otolarygology, Tokyo Women's Medical University Medical Center East) Masukawa, Ai (Department of Radiology, Tokyo Women's Medical University Medical Center East) Asanuma, Masayasu (Department of Radiology, Tokyo Women's Medical University Medical Center East) Yuhara, Toshiyuki (Department of Radiology, Tokyo Women's Medical University Medical Center East) Morita, Satoru (Department of Radiology, Tokyo Women's Medical University Medical Center East) Suzuki, Kazufumi (Department of Radiology, Tokyo Women's Medical University Medical Center East) Ueno, Eiko (Department of Radiology, Tokyo Women's Medical University Medical Center East) Sabol, John M. (GE Healthcare) |
1 | Isshiki N, Ishikawa T. Diagnostic value of tomography in unilateral vocal cord paralysis. Laryngoscope 1976;86:1573-1578 DOI ScienceOn |
2 | Agha FP. Recurrent laryngeal nerve paralysis: a laryngographic and computed tomographic study. Radiology 1983;148:149-155 DOI |
3 | Yumoto E, Sanuki T, Hyodo M. Three dimensional endoscopic images of vocal fold paralysis by computed tomography. Arch Otolaryngol Head Neck Surg 1999;125:883-890 DOI |
4 | Ricke J, Fishbach F, Freund T, Teichgraber U Hanninen EL, Rottgen R, et al. Clinical results of CsI-detector-based dualexposure dual energy in chest radiography. Eur Radiol 2003;13:2577-2582 DOI ScienceOn |
5 | McAdams HP, Samei E, Dobbins J 3rd, Tourassi GD, Ravin CE. Recent advances in chest radiography. Radiology 2006;241:663-683 DOI ScienceOn |
6 | Bacher K, Smeets P, Bonnarens K, De Hauwere A, Verstraete K, Thierens H. Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphorbased computed radiography. AJR Am J Roentgenol 2003;181:923-929 DOI ScienceOn |
7 | Tagashira H, Arakawa K, Yoshimoto M, Mochizuki T, Murase K. Detectability of lung nodules using flat panel detector with dual energy subtraction by two shot method: evaluation by ROC method. Eur J Radiol 2007;64:279-284 DOI ScienceOn |
8 | Merati AL, Shemirani N, Smith TL, Toohill RJ. Changing trends in the nature of vocal fold motion impairment. Am J Otolaryngol 2006;27:106-108 DOI ScienceOn |
9 | Yumoto E, Oyamada Y, Nakano K, Nakayama Y, Yamashita Y. Three-dimensional characteristics of the larynx with immobile vocal fold. Arch Otolaryngol Head Neck Surg 2004;130:967- 974 DOI ScienceOn |
10 | Hagan PJ. Vocal cord paralysis. Ann Otol Rhinol Laryngol 1963;72:206-222 DOI |
11 | Sabol JM, Avinash GB, Nicolas F, Claus B, Zhao J, Dobbins JT III. Development and characterization of a dual-energy subtraction imaging system for chest radiography based on CsI: T1 amorphous silicon flat-panel technology. In: Antonuk LE, Yaffe MJ, eds. Medical Imaging 2002: physics of medical imaging -- proceedings, vol. 4320. Bellingham, WA: Society of Photo-Optical Instrumentation Engineers, 2001:399-408 |
12 | Fink C, Hallscheidt PJ, Noeldge G, Kampschulte A, Radeleff B, Hosch WP, et al. Clinical comparative study with a large-area amorphous silicon flat-panel detector: image quality and visibility of anatomic structures on chest radiography. AJR Am J Roentgenol 2002;178:481-486 DOI ScienceOn |
13 | Metz CE, Herman BA, Shen JH. Maximum-likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. Stat Med 1998;17:1033-1053 DOI ScienceOn |
14 | Carderon R, Ceballos J, McGraw JP. Tomographic aspect of paralysis of the vocal cords. Radiology 1954;63:407-410 DOI |
15 | Strotzer M, Gmeinwieser JK, Volk M, Frund R, Seitz J, Feuerbach S. Detection of simulated chest lesions with normal and reduced radiation dose: comparison of conventional screenfilm radiography and a flat-panel X-ray detector based on amorphous silicon. Invest Radiol 1998;33:98-103 DOI ScienceOn |