Browse > Article
http://dx.doi.org/10.3348/kjr.2010.11.3.320

Dual-Energy Subtraction Imaging for Diagnosing Vocal Cord Paralysis with Flat Panel Detector Radiography  

Machida, Haruhiko (Department of Radiology, Tokyo Women's Medical University Medical Center East)
Yoda, Keiko (Department of Otolarygology, Tokyo Women's Medical University Medical Center East)
Arai, Yasuko (Department of Otolarygology, Tokyo Women's Medical University Medical Center East)
Nishida, Suguru (Department of Otolarygology, Tokyo Women's Medical University Medical Center East)
Masukawa, Ai (Department of Radiology, Tokyo Women's Medical University Medical Center East)
Asanuma, Masayasu (Department of Radiology, Tokyo Women's Medical University Medical Center East)
Yuhara, Toshiyuki (Department of Radiology, Tokyo Women's Medical University Medical Center East)
Morita, Satoru (Department of Radiology, Tokyo Women's Medical University Medical Center East)
Suzuki, Kazufumi (Department of Radiology, Tokyo Women's Medical University Medical Center East)
Ueno, Eiko (Department of Radiology, Tokyo Women's Medical University Medical Center East)
Sabol, John M. (GE Healthcare)
Publication Information
Korean Journal of Radiology / v.11, no.3, 2010 , pp. 320-326 More about this Journal
Abstract
Objective: To investigate the clinical feasibility of dual energy subtraction (DES) imaging to improve the delineation of the vocal cord and diagnostic accuracy of vocal cord paralysis as compared with the anterior-posterior view of flat panel detector (FPD) neck radiography. Materials and Methods: For 122 consecutive patients who underwent both a flexible laryngoscopy and conventional/DES FPD radiography, three blinded readers retrospectively graded the radiographs during phonation and inspiration on a scale of 1 (poor) to 5 (excellent) for the delineation of the vocal cord, and in consensus, reviewed the diagnostic accuracy of vocal cord paralysis employing the laryngoscopy as the reference. We compared vocal cord delineation scores and accuracy of vocal cord paralysis diagnosis by both conventional and DES techniques using ${\kappa}$statistics and assessing the area under the receiver operating characteristic curve (AUC). Results: Vocal cord delineation scores by DES (mean, $4.2{\pm}0.4$) were significantly higher than those by conventional imaging (mean, $3.3{\pm}0.5$) (p < 0.0001). Sensitivity for diagnosing vocal cord paralysis by the conventional technique was 25%, whereas the specificity was 94%. Sensitivity by DES was 75%, whereas the specificity was 96%. The diagnostic accuracy by DES was significantly superior (${\kappa}$= 0.60, AUC = 0.909) to that by conventional technique (${\kappa}$= 0.18, AUC = 0.852) (p = 0.038). Conclusion: Dual energy subtraction is a superior method compared to the conventional FPD radiography for delineating the vocal cord and accurately diagnosing vocal cord paralysis.
Keywords
Dual energy subtraction; Flat panel detector radiography; Vocal cord delineation; Vocal cord paralysis;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 Isshiki N, Ishikawa T. Diagnostic value of tomography in unilateral vocal cord paralysis. Laryngoscope 1976;86:1573-1578   DOI   ScienceOn
2 Agha FP. Recurrent laryngeal nerve paralysis: a laryngographic and computed tomographic study. Radiology 1983;148:149-155   DOI
3 Yumoto E, Sanuki T, Hyodo M. Three dimensional endoscopic images of vocal fold paralysis by computed tomography. Arch Otolaryngol Head Neck Surg 1999;125:883-890   DOI
4 Ricke J, Fishbach F, Freund T, Teichgraber U Hanninen EL, Rottgen R, et al. Clinical results of CsI-detector-based dualexposure dual energy in chest radiography. Eur Radiol 2003;13:2577-2582   DOI   ScienceOn
5 McAdams HP, Samei E, Dobbins J 3rd, Tourassi GD, Ravin CE. Recent advances in chest radiography. Radiology 2006;241:663-683   DOI   ScienceOn
6 Bacher K, Smeets P, Bonnarens K, De Hauwere A, Verstraete K, Thierens H. Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphorbased computed radiography. AJR Am J Roentgenol 2003;181:923-929   DOI   ScienceOn
7 Tagashira H, Arakawa K, Yoshimoto M, Mochizuki T, Murase K. Detectability of lung nodules using flat panel detector with dual energy subtraction by two shot method: evaluation by ROC method. Eur J Radiol 2007;64:279-284   DOI   ScienceOn
8 Merati AL, Shemirani N, Smith TL, Toohill RJ. Changing trends in the nature of vocal fold motion impairment. Am J Otolaryngol 2006;27:106-108   DOI   ScienceOn
9 Yumoto E, Oyamada Y, Nakano K, Nakayama Y, Yamashita Y. Three-dimensional characteristics of the larynx with immobile vocal fold. Arch Otolaryngol Head Neck Surg 2004;130:967- 974   DOI   ScienceOn
10 Hagan PJ. Vocal cord paralysis. Ann Otol Rhinol Laryngol 1963;72:206-222   DOI
11 Sabol JM, Avinash GB, Nicolas F, Claus B, Zhao J, Dobbins JT III. Development and characterization of a dual-energy subtraction imaging system for chest radiography based on CsI: T1 amorphous silicon flat-panel technology. In: Antonuk LE, Yaffe MJ, eds. Medical Imaging 2002: physics of medical imaging -- proceedings, vol. 4320. Bellingham, WA: Society of Photo-Optical Instrumentation Engineers, 2001:399-408
12 Fink C, Hallscheidt PJ, Noeldge G, Kampschulte A, Radeleff B, Hosch WP, et al. Clinical comparative study with a large-area amorphous silicon flat-panel detector: image quality and visibility of anatomic structures on chest radiography. AJR Am J Roentgenol 2002;178:481-486   DOI   ScienceOn
13 Metz CE, Herman BA, Shen JH. Maximum-likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. Stat Med 1998;17:1033-1053   DOI   ScienceOn
14 Carderon R, Ceballos J, McGraw JP. Tomographic aspect of paralysis of the vocal cords. Radiology 1954;63:407-410   DOI
15 Strotzer M, Gmeinwieser JK, Volk M, Frund R, Seitz J, Feuerbach S. Detection of simulated chest lesions with normal and reduced radiation dose: comparison of conventional screenfilm radiography and a flat-panel X-ray detector based on amorphous silicon. Invest Radiol 1998;33:98-103   DOI   ScienceOn