Source Current Control Strategy of Active Power Filters for Unbalanced Load Compensation in Three-Phase Four-Wire Distribution Networks  

Wang, Lei (Shanxi Key Lab of Power System Operation and Control, College of Electrical and Power Engineering, Taiyuan University of Technology)
Han, Xiaoqing (Shanxi Key Lab of Power System Operation and Control, College of Electrical and Power Engineering, Taiyuan University of Technology)
Meng, Runquan (Shanxi Key Lab of Power System Operation and Control, College of Electrical and Power Engineering, Taiyuan University of Technology)
Ren, Chunguang (Shanxi Key Lab of Power System Operation and Control, College of Electrical and Power Engineering, Taiyuan University of Technology)
Wang, Qi (Shanxi Key Lab of Power System Operation and Control, College of Electrical and Power Engineering, Taiyuan University of Technology)
Zhang, Baifu (Shanxi Key Lab of Power System Operation and Control, College of Electrical and Power Engineering, Taiyuan University of Technology)
Publication Information
Journal of Power Electronics / v.18, no.5, 2018 , pp. 1545-1554 More about this Journal
Abstract
This paper proposes a modified control strategy to improve the performance of three-phase four-leg shunt active power filters (APFs) for the compensation of three phase unbalanced loads. Unbalanced current cannot be obtained accurately by a harmonic detector due to the lower frequency. The proposed control strategy eliminates conventional harmonic detectors by directly regulating the source current. Therefore, the computational complexity is greatly reduced and the performance of the APF is improved. A mathematic model has been developed based on the source currents. The corresponding controllers have been designed based on the sinusoidal internal model principle. The proposed control strategy can guarantee excellent compensation performance and stable operation after an extreme disturbance such as a short circuit fault. In addition, the proposed technique can selectively compensate specific harmonics. A 50kVA prototype APF is implemented in the laboratory to validate the feasibility and performance of the proposed control strategy.
Keywords
Active Power Filter (APF); Source current control; Unbalanced load compensation;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 F. Z. Peng, G. W. Ott, and D. J. Adams, “Harmonic and reactive power compensation based on the generalized instantaneous reactive power theory for three-phase four-wire systems,” IEEE Trans. Power Electron., Vol. 13, No. 5, pp. 1174-1181, Nov. 1998.
2 G. W. Chang and T.-C. Shee, “A novel reference compensation current strategy for shunt active power filter control,” IEEE Trans. Power Del., Vol. 19, No. 4, pp. 1751-1758, Oct. 2004.   DOI
3 H. Li, F. Zhuo, Z. Wang, W. Lei, and L. Wu, “A novel time-domain current-detection algorithm for shunt active power filters,” IEEE Trans. Power Syst., Vol. 20, No. 2, pp. 644-651, May 2005.   DOI
4 R. S. Herrera and P. Salmeron, “Instantaneous reactive power theory: A reference in the nonlinear loads compensation,” IEEE Trans. Ind. Electron., Vol. 56, No. 6, pp. 2015-2022, Jun. 2009.   DOI
5 R. S. Herrera, P. Salmeron, and K. Hyosung, “Instantaneous reactive power theory applied to active power filter compensation: Different approaches, assessment, and experimental results,” IEEE Trans. Ind. Electron., Vol. 55, No. 1, pp. 184-196, Jan. 2008.   DOI
6 M. J. Newman, D. N. Zmood, and D. G. Holmes, “Stationary frame harmonic reference generation for active filter systems,” IEEE Trans. Ind. Appl., Vol. 38, No. 6, pp. 1591-1599, Nov./Dec. 2002.   DOI
7 M. Kesler and E. Ozdemir, “Synchronous-reference-frame-based control method for UPQC under unbalanced and distorted load conditions,” IEEE Trans. Ind. Electron., Vol. 58, No. 9, pp. 3967-3975, Sep. 2011.   DOI
8 B. Singh and V. Verma, “Selective compensation of power-quality problems through active power filter by current decomposition,” IEEE Trans. Power Del., Vol. 23, No. 2, pp. 792-799, Apr. 2008.   DOI
9 S. Rahmani, N. Mendalek, and K. Al-Haddad, “Experimental design of a nonlinear control technique for three-phase shunt active power filter,” IEEE Trans. Ind. Electron., Vol. 57, No. 10, pp. 3364-3375, Oct. 2010.   DOI
10 H. Haibing and X. Yan, “Design considerations and fully digital implementation of 400-Hz active power filter for aircraft applications,” IEEE Trans. Ind. Electron., Vol. 61, No. 8, pp. 3823-3834, Aug. 2014.   DOI
11 A. Bhattacharya and C. Chakraborty, “A shunt active power filter with enhanced performance using ANN-based predictive and adaptive controllers,” IEEE Trans. Ind. Electron., Vol. 58, No. 2, pp. 421-428, Feb. 2011.   DOI
12 M. Qasim, P. Kanjiya, and V. Khadkikar, “Artificial-neural-network based phase-locking scheme for active power filters,” IEEE Trans. Ind. Electron., Vol. 61, No. 8, pp. 3857-3866, Aug. 2014.   DOI
13 P. Kanjiya, V. Khadkikar, and H. H. Zeineldin, “Optimal control of shunt active power filter to meet IEEE Std. 519 current harmonic constraints under nonideal supply condition,” IEEE Trans. Ind. Electron., Vol. 62, No. 2, pp. 724-734, Feb. 2015.   DOI
14 L. Wang, X. Han, C. Ren, Y. Yang, and P. Wang, “A modified one-cycle-control-based active power filter for harmonic compensation,” IEEE Trans. Ind. Electron., Vol. 65, No. 1, pp. 738-748, Jan. 2018.   DOI
15 P. Kanjiya, V. Khadkikar, and H. H. Zeineldin, “A noniterative optimized algorithm for shunt active power filter under distorted and unbalanced supply voltages,” IEEE Trans. Ind. Electron., Vol. 60, No. 12, pp. 5376-5390, Dec. 2013.   DOI
16 Z. Zou, K. Zhou, Z. Wang, and M. Cheng, “Frequency adaptive fractional order repetitive control of shunt active power filters,” IEEE Trans. Ind. Electron., Vol. 62, No. 3, pp. 1659-1668, Mar. 2015.   DOI
17 K. M. Smedley, L. Zhou, and C. Qiao, “Unified constant-frequency integration control of active power filters-steady-state and dynamics,” IEEE Trans. Power Electron., Vol. 16, No. 3, pp. 428-436, May 2001.   DOI
18 J. Taotao and K. M. Smedley, “Operation of one-cycle controlled threephase active power filter with unbalanced source and load,” IEEE Trans. Power Electron., Vol. 21, No. 5, pp. 1403-1412, Sep. 2006.   DOI
19 H. Akagi, “New trends in active filters for power conditioning,” IEEE Trans. Ind. Appl., Vol. 32, No. 2, pp. 1312-1332, Nov./Dec. 1996.   DOI
20 V. B. Bhavaraju and Prasad N. Enjeti, "Analysis and design of an active power filter for balancing unbalanced loads," IEEE Trans. Power Electron., Vol. 8, No. 4, pp. 640-647, Oct. 1993.   DOI
21 P. Verdelho and G. D. Marques, “An active power filter and unbalanced current compensator,” IEEE Trans. Ind. Electron., Vol. 44, No. 3, pp. 321-328, Jun. 1997.   DOI
22 B. Singh, K. Al-Haddad, and A. Chandra, “A review of active filters for power quality improvement,” IEEE Trans. Ind. Electron., Vol. 46, No. 5, pp. 960-971, Oct. 1999.
23 L. Asiminoaei, F. Blaabjerg, and S. Hansen, “Detection is key-Harmonic detection methods for active power filter applications,” IEEE Ind. Appl. Mag., Vol. 13, No. 4, pp. 22-33, Jul./Aug. 2007.   DOI
24 M. Angulo, J. Lago, D. Ruiz-Caballero, S. Mussa, and M. Heldwein, “Active power filter control strategy with implicit closed loop current control and resonant controller,” IEEE Trans. Ind. Electron., Vol. 6, No. 7, pp. 2721-2730, Jul. 2013.
25 M. Aredes, J. Häfner, and K. Heumann, “Three-phase four-wire shunt active filter control strategies,” IEEE Trans. Power Electron., Vol. 12, No. 2, pp. 311-318, Mar. 1997.   DOI
26 L. Wang, C. Ren, Y. Yang, X. Han, and P. Wang, “An improved one cycle control for active power filters under non-ideal voltage conditions,” J. Power Electron., Vol. 16, No. 6, pp. 2350-2358, Nov. 2016.   DOI
27 H. Yi, F. Zhuo, Y. Zhang, Y. Li, W. Chen, and J. Liu, “A source-current-detected shunt active power filter control scheme based on vector resonant controller,” IEEE Trans. Ind. Appl., Vol. 50, No. 3, pp. 1953-1965, May/Jun. 2014.   DOI
28 R. L. de Araujo Ribeiro, T. de Oliveira Alves Rocha, R. M. de Sousa, E. C. dos Santos, Jr., and A. M. Nogueira Lima, “A robust DC-link voltage control strategy to enhance the performance of shunt active power filters without harmonic detection schemes,” IEEE Trans. Ind. Electron., Vol. 62, No. 2, pp. 803-813, Feb. 2015.   DOI
29 Q.-N. Trinh and H.-H. Lee, “An advanced current control strategy for three-phase shunt active power filters,” IEEE Trans. Ind. Electron., Vol. 60, No. 12, pp. 5400-5410, Dec. 2013.   DOI
30 H. Y. Kanaan, K. Al-Haddad, A. A. Assi, J. B. Sleiman, M. Aoun, and C. Asmar, "Averaged modeling and control of a three-phase series active power filter for voltage harmonic compensation," in Proc. IEEE 29th Annu. Conf. Industrial Electronics Soc., Vol. 1, pp. 255-260, 2003.
31 S. Fukuda and T. Yoda, “A novel current-tracking method for active filters based on a sinusoidal internal model,” IEEE Trans. Ind. Appl., Vol. 37, No. 3, pp. 888-895, May 2001.   DOI
32 S. Fukuda and R. Imamura, "Application of a sinusoidal internal model to current control of three-phase utility-interface converters," IEEE Trans. Ind. Electron., Vol. 52, No. 2, pp. 420-426, Apr. 2005.   DOI