Abstract
With the publication of TRS-483 in late 2017 the IAEA has established an international code of practice for reference dosimetry in small and non-standard fields based on a formalism first suggested by Alfonso et al. in 2008. However, data on beam quality correction factors ($k^{f_{msr},f_{ref}}_{Q_{msr},Q_0}$) for the Leksell Gamma $Knife^{(R)}$ $Perfexion^{TM}$ is scarce and what little data is available was obtained under conditions not necessarily in accordance with the IAEA's recommendations. This study constitutes the first systematic attempt to calculate those correction factors by applying the new code of practice to Monte Carlo simulation using the GEANT4 toolkit. $k^{f_{msr},f_{ref}}_{Q_{msr},Q_0}$ values were determined for three common ionization chamber detectors and five different phantom materials, with results indicating that in most phantom materials, all chambers were well suited for reference dosimetry with the Gamma $Knife^{(R)}$. Similarities and differences between the results of this study and previous ones were also analyzed and it was found that the results obtained herein were generally in good agreement with earlier PENELOPE and EGSnrc studies.
Keywords
GEANT4; Gamma Knife; Perfexion; Beam quality correction factor; $k^{f_{msr},f_{ref}}_{Q_{msr},Q_0}$; Calibration; Small field dosimetry; TRS-483;
Citations & Related Records
연도 인용수 순위
  • Reference
1 C. Lindquist and I. Paddick, Operative Neurosurgery 61, ONS-131 (2007).
2 C. M. Poole et al., IEEE Trans. Nucl. Sci. 59, 1695 (2012).   DOI
3 T. H. Kim et al., Development of IAEA phase-space database for Leksell Gamma Knifer$^{(R)}$ $Perfexion^{TM}$ using multi-threaded GEANT4 simulation, Phys. Med. Biol. (2018) (under review).
4 EStar material composition database of the US National Institute of Standards and Technology, https://physics.nist.gov/cgi-bin/Star/compos.pl.
5 F. Araki, Physica Medica 39, 132 (2017).   DOI
6 J. Novotny Jr. et al., Med. Phys. 37, 5066 (2010).   DOI
7 Homepage of the GEANT4 simulation toolkit at CERN, https://geant4.web.cern.ch/.
8 S. Incerti, M. Asai and D. Wright, GEANT4 Tutorial at KIRAMS, Seoul, Korea, (2017) (http://geant4.in2p3.fr/IMG/pdf PhysicsLists.pdf).
9 British Institute of Radiology, Central Axis Depth Dose Data for Use in Radiotherapy, British Journal of Radiology Supplement 25, London (1996).
10 J. Allison et al., Nucl. Instrum. Meth. Phys. Res. A 835, 186 (2015).
11 G. M. Mora, A. Maio and D. W. Rogers, Med. Phys. 26, 2494 (1999).   DOI
12 International Atomic Energy Agency, Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water, Technical Report Series No. 398, Vienna (2000).
13 P. R. Almond et al., Med. Phys. 26, 1847 (1999).   DOI
14 Institute of Physics and Engineering in Medicine, Small eld MV photon dosimetry, IPEM Report No. 103, York (2010).
15 R. Alfonso et al., Med. Phys. 35, 5179 (2008).   DOI
16 International Atomic Energy Agency, Dosimetry of small static fields used in external beam radiotherapy: an IAEA-AAPM international code of practice for reference and relative dose determination, Technical Report Series No. 483, Vienna (2017).
17 J. Johansson et al., Presentation at the 16th International Meeting of the Leksell Gamma Knifer$^{(R)}$ Society, Sydney (2012).
18 E. Zoros et al., Phys. Med. Biol. 62, 7532 (2017).   DOI
19 L. Mirzakhanian, H. Benmakhlouf, F. Tessier and J. Seutjens, Med. Phys. 45, 1748 (2018).   DOI