The generation of coherent x-ray beams by using a multi-slit diffraction phenomenon is presented. The mode-confinement conditions in the x-ray waveguide (XWG) needed to obtain single-mode beams are determined. The XWGs are stacked to form an XWG array. The core of the XWG array is used as a slit in an opaque screen, similar to those used for visible light. Diffraction patterns that interfered constructively in the XWG array are investigated based on multi-slit diffraction theory. The irradiance distributions are studied at on observation screen. The FWHM of diffracted x-ray spectra were between $1.67{\times}10^{-4}$ to $3.30{\times}10^{-5}$ radians which lead to a spot-size of a few tens of micrometers on the screen at distance of 1 m. The intensities decrease with increase in the period of the XWG array, i.e. a thicker cladding, due to growth of the higher-order diffraction peaks.
Keywords
Waveguide array; Coherent x-ray; Diffraction;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 C. Bergermann, H. Keymeulen, and J. F. van der Veen, “Focusing x-ray beams to nanometer dimensions,” Phys. Rev. Lett. 91, 204801-1-204801-4 (2003).   DOI   ScienceOn
2 P. M. Blancherd, A. H. Greenaway, A. R. Harvey, and K. Webster, “Coherent optical beam forming with passive millimeter-wave arrays,” IEEE J. Lightwave Technol. 17, 418-425 (1999).   DOI   ScienceOn
3 Center for X-ray Optics Web Site: www-cxro.lbl.gov/.
4 J. Choi, J. Jung, and T. Kwon, “Mode propagation in x-ray waveguides,” J. Opt. Soc. Korea 12, 112-117 (2008).   과학기술학회마을   DOI   ScienceOn
5 L. I. Ognev, “X-ray diffraction effects in a submicron slits and channel,” X-ray Spectrom. 31, 274-277 (2002).   DOI   ScienceOn
6 C. Ollinger, C. Fufse, A. Jarre, and T. Salditt, “Two-dimensional x-ray waveguides on a grating,” Physica B 357, 53-56 (2005).   DOI   ScienceOn
7 I. A. Vartanyants, I. K. Robinson, J. D. Onken, M. A. Pfeifer, G. J. Williams, F. Pfeiffer, H. Metzger, Z. Zhong, and G. Bauer, “Coherent x-ray diffraction from quantum dots,” Phys. Rev. B 71, 245302-1-245302-9 (2005).   DOI   ScienceOn
8 J. Miao, Y. Nishino, Y. Kohmura, B. Johnson, C. Song, S. H. Risbud, and T. Ishikawa, “Quantitative image reconstruction of GaN quantum dotsfrom oversampled diffraction intensities alone,” Phys. Rev. Lett. 95, 085503-1-085503-4 (2005).   DOI   ScienceOn
9 S. Marchesini, H. N. Chapman, S. P. Hau-Riege, R. A. London, and A. Szoke, “Coherent x-ray diffraction image: applications and limitations,” Opt. Express 11, 2344-2353 (2003).   DOI
10 C. Fuhse, C. Ollinger, and T. Salditt, “Waveguide-based off-axis holography with hard x-rays,” Phys. Rev. Lett. 97, 254801-1-254801-4 (2006).   DOI   ScienceOn
11 G. J. Williams, H. M. Quiney, B. B. Dhal, C. Q. Tran, K. A. Nugent, A. G. Peele, D. Paterson, and M. D. de Jonge, “Fresnel coherent diffractive imaging,” Phys. Rev. Lett. 97, 025506-1-025506-4 (2006).   DOI   ScienceOn
12 W. Jark, A. Cedola, S. D. Forzo, M. Fiordelisi, S. Lagomarsino, N. V. Kovalenko, and V. A. Chernov, “High Gsin beam compression in new-generation thin-film x-ray waveguides,” Appl. Phys. Lett. 78, 1192-1194 (2001).   DOI   ScienceOn
13 J. H. H. Bongaerts, M. J. Zwanenbury, F. Zontone, and J. F. van der Veen, “Propagation of coherent x-rays in a multistep-index x-ray waveguide,” J. Appl. Phys. 90, 94-100 (2001).   DOI   ScienceOn