A Method of Accurate Position Control with a Pneumatic Cylinder Driving Apparatus  

Jang Ji-Seong (Division of Mechanical Engineering, Pukyong National University)
Byun Jung-Hoan (Faculty of Marine Technology, Chonnam National University)
Publication Information
Journal of Mechanical Science and Technology / v.20, no.7, 2006 , pp. 993-1001 More about this Journal
Abstract
In this paper, a method of accurate position control using a pneumatic cylinder driving apparatus is presented. To overcome the effect of friction force and transmission line, low friction type cylinder applied externally pressurized air bearing structure is used and two control valves attached both side of the cylinder directly. To compensate nonlinear characteristics of control valves, linearized control input derived from the relation between control input and effective area of control valve, and dither signal are applied to the valve. The controller applied to the pneumatic cylinder driving apparatus is composed of a state feedback controller and a disturbance observer. Experimental results show that the effectiveness of the proposed method and position control error of $5{\mu}m$ accuracy could be obtained easily.
Keywords
Accurate Position Control; Nonlinear Characteristics; Pneumatic Cylinder Driving Apparatus;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Kosaki, T. and Sano, M., 2002, 'Computation of Friction Force in a Labyrinth-Sealed Pneumatic Cylinder,' Transactions of the Japan Hydraulics and Pneumatics Society, Vol. 33, No.1, pp.9-14
2 Lai, J. Y., Menq, C. H. and Singh, R., 1990, 'Accurate Position Control of a Pneumatic Actuator,' Journal of Dynamic Systems, Measurement and Control, Vol. 112, pp. 734-739   DOI
3 McGuirk, D. P., Pingdong, W. and Xiao, X., 1998, 'Fluid Power in the world,' Journal of the Japan Fluid Power System Society, Vol. 29, No. 3, pp. 212-243
4 Saito, T., Ikeda, H., Sugimoto, H. and Ikebe, J., 1995, 'A Study on the Low Velocity Control of A Pneumatic Cylinder,' Journal of the Japan Hydraulics and Pneumatics Society, Vol. 26, No. 6, pp. 804-810   DOI
5 Situm, Z., Pavkovic, D. and Novakkovic, B., 2004, 'Servo Pneumatic Position Control Using Fuzzy PID Gain Scheduling,' Journal of Dynamic Systems, Measurement and Control, Vol. 126, pp. 376-387   DOI   ScienceOn
6 Tokashiki, L. R., Fujita, T., Kagawa, T. and Ikegami, T., 2000, 'Stick-Slip Motion in Pneumatic Cylinder Driven by Meter Out Circuit,' Transactions of the Japan Fluid Power System Society, Vol. 31, No.6, pp. 170-175
7 Yoshimitu, T. and Oyama, O., 2002, 'Discrimination and Control of a Pneumatic Cylinder under Stick or Slip Mode of Seal,' Transactions of the Japan Fluid Power System Society, Vol. 33, No.3, pp. 57-62   DOI
8 Hanafusa, H., 1982, 'Design of Electrohydraulic Servo Control Systems for Articulated Robot Arm Control,' The Japan Hydraulics & Pneumatics Society, Vol. 20, No.7, pp.429-436
9 Helduser, S. and Muth, A., 1996, 'Dynamic Friction Measurement Method Evaluated by Means of Cylinders and Valves,' Proceedings of the Third JHPS International Symposium on Fluid Power, pp. 271-276
10 Jang, J. S., 2002, 'Position Control of a Pneumatic Cylinder with a Nonlinear Compensator and a Disturbance Observer,' Transactions of the KSME, A, Vol. 25, No.9, pp.1795-1805   과학기술학회마을   DOI
11 Johira, T., 1997, 'Pneumatic Servo System,' Transactions of the Japan Hydraulics and Pneumatics Society, Vol. 28, No.7, pp. 748-752
12 Kawai, S., Kawakami, Y. and Masuda., 1993, 'Some Consideration on the Position Control of Pneumatic Cylinder,' Proceedings of the Second JHPS International Symposium on Fluid Power, pp.563-568
13 Kawashima, K., Oogami, H. and Yang, W. J., 1998, 'Precision Intra-Stroke Stopping with a Precision of submicron in Pneumatic Cylinder,' Transactions of the Japan Hydraulics and Pneumatics Society, Vol. 29, No.4, pp.95-99
14 Kimura, T., Fujioka, H., Tokai, K. and Takamori, T., 2004, 'Sampled-Data $H_{\infty}$ Control for a Pneumatic Cylinder System,' Transaction of the Japan Fluid Power System Society, Vol. 34, No.3, pp.62-65